Literature DB >> 28742775

Estimation of Stroke Volume and Stroke Volume Changes by Electrical Impedance Tomography.

Fernando José da Silva Ramos1, André Hovnanian1,2, Rogério Souza2, Luciano C P Azevedo1, Marcelo B P Amato2, Eduardo L V Costa1,2.   

Abstract

BACKGROUND: Electrical impedance tomography (EIT) is a noninvasive imaging method that identifies changes in air and blood volume based on thoracic impedance changes. Recently, there has been growing interest in EIT to measure stroke volume (SV). The objectives of this study are as follows: (1) to evaluate the ability of systolic impedance variations (ΔZsys) to track changes in SV in relation to a baseline condition; (2) to assess the relationship of ΔZsys and SV in experimental subjects; and (3) to identify the influence of body dimensions on the relationship between ΔZsys and SV.
METHODS: Twelve Agroceres pigs were instrumented with transpulmonary thermodilution catheter and EIT and were mechanically ventilated in a random order using different settings of tidal volume (VT) and positive end-expiratory pressure (PEEP): VT 10 mL·kg and PEEP 10 cm H2O, VT 10 mL·kg and PEEP 5 cm H2O, VT 6 mL·kg and PEEP 10 cm H2O, and VT 6 mL·kg and PEEP 5 cm H2O. After baseline data collection, subjects were submitted to hemorrhagic shock and successive fluid challenges.
RESULTS: A total of 204 paired measurements of SV and ΔZsys were obtained. The 4-quadrant plot showed acceptable trending ability with a concordance rate of 91.2%. Changes in ΔZsys after fluid challenges presented an area under the curve of 0.83 (95% confidence interval, 0.74-0.92) to evaluate SV changes. Conversely, the linear association between ΔZsys and SV was poor, with R from linear mixed model of 0.35. Adding information on body dimensions improved the linear association between ΔZsys and SV up to R from linear mixed model of 0.85.
CONCLUSIONS: EIT showed good trending ability and is a promising hemodynamic monitoring tool. Measurements of absolute SV require that body dimensions be taken into account.

Entities:  

Mesh:

Year:  2018        PMID: 28742775     DOI: 10.1213/ANE.0000000000002271

Source DB:  PubMed          Journal:  Anesth Analg        ISSN: 0003-2999            Impact factor:   5.108


  8 in total

1.  The use of pulse pressure variation for predicting impairment of microcirculatory blood flow.

Authors:  Christoph R Behem; Michael F Graessler; Till Friedheim; Rahel Kluttig; Hans O Pinnschmidt; Anna Duprée; E Sebastian Debus; Daniel A Reuter; Sabine H Wipper; Constantin J C Trepte
Journal:  Sci Rep       Date:  2021-04-28       Impact factor: 4.379

2.  Real-Time Measurements of Relative Tidal Volume and Stroke Volume Using Electrical Impedance Tomography with Spatial Filters: A Feasibility Study in a Swine Model Under Normal and Reduced Ventilation.

Authors:  Geuk Young Jang; Chi Ryang Chung; Ryoung Eun Ko; Jin Young Lee; Tong In Oh; Gee Young Suh; Yongmin Kim; Eung Je Woo
Journal:  Ann Biomed Eng       Date:  2022-08-12       Impact factor: 4.219

3.  Increasing Veno-Arterial Extracorporeal Membrane Oxygenation Flow Reduces Electrical Impedance of the Lung Regions in Porcine Acute Heart Failure.

Authors:  M Popková; E Kuriščák; P Hála; D Janák; L Tejkl; J Bělohlávek; P Ošťádal; P Neužil; O Kittnar; M Mlček
Journal:  Physiol Res       Date:  2020-06-25       Impact factor: 1.881

Review 4.  Electrical impedance tomography in perioperative medicine: careful respiratory monitoring for tailored interventions.

Authors:  Elena Spinelli; Tommaso Mauri; Alberto Fogagnolo; Gaetano Scaramuzzo; Annalisa Rundo; Domenico Luca Grieco; Giacomo Grasselli; Carlo Alberto Volta; Savino Spadaro
Journal:  BMC Anesthesiol       Date:  2019-08-07       Impact factor: 2.217

5.  Prediction of Fluid Responsiveness by Stroke Volume Variation in Children Undergoing Fontan Operation.

Authors:  Yun'an Song; Huiyan Hou; Jie Bai; Hongbin Gu
Journal:  Biomed Res Int       Date:  2020-11-07       Impact factor: 3.411

6.  Electrical impedance tomography in pulmonary arterial hypertension.

Authors:  André L D Hovnanian; Eduardo L V Costa; Susana Hoette; Caio J C S Fernandes; Carlos V P Jardim; Bruno A Dias; Luciana T K Morinaga; Marcelo B P Amato; Rogério Souza
Journal:  PLoS One       Date:  2021-03-17       Impact factor: 3.240

7.  Accuracy and reliability of noninvasive stroke volume monitoring via ECG-gated 3D electrical impedance tomography in healthy volunteers.

Authors:  Fabian Braun; Martin Proença; Andy Adler; Thomas Riedel; Jean-Philippe Thiran; Josep Solà
Journal:  PLoS One       Date:  2018-01-26       Impact factor: 3.240

Review 8.  Electrical impedance tomography in acute respiratory distress syndrome.

Authors:  M Consuelo Bachmann; Caio Morais; Guillermo Bugedo; Alejandro Bruhn; Arturo Morales; João B Borges; Eduardo Costa; Jaime Retamal
Journal:  Crit Care       Date:  2018-10-25       Impact factor: 9.097

  8 in total