Literature DB >> 6376537

Clinical comparison of the Isolator 1.5 microbial tube and the BACTEC radiometric system for detection of bacteremia in children.

R B Carey.   

Abstract

The Isolator 1.5 microbial tube (E. I. du Pont de Nemours & Co., Inc., Wilmington , Del.) was compared with the BACTEC radiometric detection system (Johnston Laboratories, Inc., Cockeysville, Md.) for the detection of bacteremia in children. The Isolator 1.5 is a blood culture system designed for small volumes of blood (0.5 to 1.5 ml). The method involves lysis of the cells of the patient and the direct plating of the entire blood lysate on agar media appropriate for the growth of fastidious microorganisms. Of 1,500 paired samples inoculated into the two systems, 68 were positive for 73 clinically significant organisms. The Isolator 1.5 recovered 81% of the positive cultures compared with 84% recovered by the BACTEC system. When paired blood samples with disproportionate volumes were excluded, the Isolator 1.5 detected 3% more positive cultures. More isolates of Streptococcus pneumoniae and Neisseria meningitidis were recovered by the Isolator 1.5, whereas Haemophilus influenzae was recovered most often in the BACTEC bottles (P greater than 0.1). The contamination rates were 8.7 and 3.1% for the Isolator 1.5 and the BACTEC system, respectively. In cultures positive by both systems, the mean time to detection was 4.1 h faster with the Isolator 1.5. The mean time to obtain isolated colonies was 26.6 h faster with the Isolator 1.5. These data indicate the potential value of the Isolator 1.5 microbial tube as a simple, rapid, and sensitive method for the detection of bacteremia in children.

Entities:  

Mesh:

Year:  1984        PMID: 6376537      PMCID: PMC271145          DOI: 10.1128/jcm.19.5.634-638.1984

Source DB:  PubMed          Journal:  J Clin Microbiol        ISSN: 0095-1137            Impact factor:   5.948


  11 in total

1.  Evaluation of a lysis-centrifugation system for recovery of yeasts and filamentous fungi from blood.

Authors:  J Bille; L Stockman; G D Roberts; C D Horstmeier; D M Ilstrup
Journal:  J Clin Microbiol       Date:  1983-09       Impact factor: 5.948

2.  Effect of sodium polyanethol sulfonate in blood cultures.

Authors:  J Eng
Journal:  J Clin Microbiol       Date:  1975-02       Impact factor: 5.948

3.  Clinical laboratory comparison of lysis-centrifugation and BACTEC radiometric blood culture techniques.

Authors:  J C McLaughlin; P Hamilton; J V Scholes; R C Bartlett
Journal:  J Clin Microbiol       Date:  1983-11       Impact factor: 5.948

4.  Evaluation of a lysis-centrifugation and biphasic bottle blood culture system during routine use.

Authors:  M T Kelly; G E Buck; M F Fojtasek
Journal:  J Clin Microbiol       Date:  1983-09       Impact factor: 5.948

5.  False no-growth blood cultures in pneumococcal pneumonia.

Authors:  C C Adeniyi-Jones; D L Stevens; E S Rasquinha
Journal:  J Clin Microbiol       Date:  1980-10       Impact factor: 5.948

6.  Improved blood culture technique based on centrifugation: clinical evaluation.

Authors:  G L Dorn; G A Land; G E Wilson
Journal:  J Clin Microbiol       Date:  1979-03       Impact factor: 5.948

7.  Controlled evaluation of the volume of blood cultured in detection of bacteremia and fungemia.

Authors:  J H Tenney; L B Reller; S Mirrett; W L Wang; M P Weinstein
Journal:  J Clin Microbiol       Date:  1982-04       Impact factor: 5.948

8.  New centrifugation blood culture device.

Authors:  G L Dorn; K Smith
Journal:  J Clin Microbiol       Date:  1978-01       Impact factor: 5.948

9.  Blood culture technique based on centrifugation: clinical evaluation.

Authors:  G L Dorn; G G Burson; J R Haynes
Journal:  J Clin Microbiol       Date:  1976-03       Impact factor: 5.948

10.  Detection and quantitation of bacteremia in childhood.

Authors:  M Santosham; E R Moxon
Journal:  J Pediatr       Date:  1977-11       Impact factor: 4.406

View more
  24 in total

1.  Tampon sampling for diagnosis of bacterial vaginosis: a potentially useful way to detect genital infections?

Authors:  D Wilkinson; N Ndovela; A Kharsany; C Connolly; A W Sturm
Journal:  J Clin Microbiol       Date:  1997-09       Impact factor: 5.948

2.  Use of the isolator 1.5 microbial tube for culture of synovial fluid from patients with septic arthritis.

Authors:  P Yagupsky; J Press
Journal:  J Clin Microbiol       Date:  1997-09       Impact factor: 5.948

Review 3.  Neonatal infections with coagulase negative staphylococci.

Authors:  M R Millar; N Todd; P Mackay
Journal:  Arch Dis Child       Date:  1990-10       Impact factor: 3.791

4.  Assessment of the BACTEC NR660 blood culture system for the detection of bacteremia in young children.

Authors:  J D Anderson; C Trombley; N Cimolai
Journal:  J Clin Microbiol       Date:  1989-04       Impact factor: 5.948

5.  Quantitative blood cultures for diagnosis and management of catheter-related sepsis in pediatric hematology and oncology patients.

Authors:  M C Douard; G Arlet; G Leverger; R Paulien; C Waintrop; E Clementi; B Eurin; G Schaison
Journal:  Intensive Care Med       Date:  1991       Impact factor: 17.440

Review 6.  Detection of bloodstream infections in children.

Authors:  J M Campos
Journal:  Eur J Clin Microbiol Infect Dis       Date:  1989-09       Impact factor: 3.267

7.  Effect of delay in processing on lysis-centrifugation blood culture results from marrow transplant patients.

Authors:  D J Hamilton; D Amos; R W Schwartz; C M Dent; G W Counts
Journal:  J Clin Microbiol       Date:  1989-07       Impact factor: 5.948

8.  Clinical comparison of the recoveries of bloodstream pathogens in Septi-Chek brain heart infusion broth with saponin, Septi-Chek tryptic soy broth, and the isolator lysis-centrifugation system.

Authors:  P R Murray; A W Spizzo; A C Niles
Journal:  J Clin Microbiol       Date:  1991-05       Impact factor: 5.948

9.  Comparison of Isolator 1.5 and BACTEC NR660 aerobic 6A blood culture systems for detection of fungemia in children.

Authors:  C A Petti; A K Zaidi; S Mirrett; L B Reller
Journal:  J Clin Microbiol       Date:  1996-08       Impact factor: 5.948

10.  Comparison of lysis filtration and an automated blood culture system (BACTEC) for detection, quantification, and identification of odontogenic bacteremia in children.

Authors:  Victoria S Lucas; Vasiliki Lytra; Thoraya Hassan; Helen Tatham; M Wilson; Graham J Roberts
Journal:  J Clin Microbiol       Date:  2002-09       Impact factor: 5.948

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.