Literature DB >> 3068248

Comparative evaluation of the oxoid signal and Roche Septi-Chek blood culture systems.

P R Murray1, A C Niles, R L Heeren, M M Curren, L E James, J E Hoppe-Bauer.   

Abstract

The Oxoid Signal blood culture system (Oxoid USA, Inc., Columbia, Md.) was compared with the Roche Septi-Chek system (Roche Diagnostics, Div. Hoffmann-La Roche Inc., Nutley, N.J.), with the latter consisting of a tryptic soy broth (R-TSB) bottle with an attached agar slide unit and a Columbia broth bottle. A total of 5,034 cultures with equal volumes of blood in each bottle were processed. Overall, more organisms were recovered in the R-TSB bottle than in the Signal bottle, with significantly more aerobic organisms (Pseudomonas spp., Acinetobacter spp., and yeasts) recovered in the R-TSB bottles and anaerobes and viridans group streptococci recovered in Signal bottles. Approximately equivalent numbers of organisms were recovered in the Signal and Columbia broth bottles. The times of detection were essentially identical with the three blood culture broth systems. During the study, 30.6% of the Signal bottles had a positive indicator of growth, of which 1,103 (71.7%) were false-positive cultures. Additionally, nonviable organisms resembling streptococci were observed in 13.7% of the Signal bottles that were Gram stained and in unioculated blood culture bottles. With appropriate modifications of the preparation of the media, the latter problem can be eliminated.

Entities:  

Mesh:

Substances:

Year:  1988        PMID: 3068248      PMCID: PMC266938          DOI: 10.1128/jcm.26.12.2526-2530.1988

Source DB:  PubMed          Journal:  J Clin Microbiol        ISSN: 0095-1137            Impact factor:   5.948


  13 in total

1.  Novel method for detecting micro-organisms in blood cultures.

Authors:  D Sawhney; S Hinder; D Swaine; E Y Bridson
Journal:  J Clin Pathol       Date:  1986-11       Impact factor: 3.411

2.  Clinical comparison of a new automated infrared blood culture system with the BACTEC 460 system.

Authors:  D Jungkind; J Millan; S Allen; J Dyke; E Hill
Journal:  J Clin Microbiol       Date:  1986-02       Impact factor: 5.948

3.  Early detection of bacterial growth, with carbon-14-labeled glucose.

Authors:  F H DeLand; H N Wagner
Journal:  Radiology       Date:  1969-01       Impact factor: 11.105

4.  Clinical laboratory comparison of a slide blood culture system with a conventional broth system.

Authors:  M A Pfaller; T K Sibley; L M Westfall; J E Hoppe-Bauer; M A Keating; P R Murray
Journal:  J Clin Microbiol       Date:  1982-09       Impact factor: 5.948

5.  Optimal time for routine early subculture of blood cultures.

Authors:  H S Sliva; J A Washington
Journal:  J Clin Microbiol       Date:  1980-09       Impact factor: 5.948

6.  Controlled evaluation of modified radiometric blood culture medium supplemented with gelatin for detection of bacteremia and fungemia.

Authors:  M P Weinstein; L B Reller; S Mirrett; L G Reimer; W L Wang; C W Stratton
Journal:  J Clin Microbiol       Date:  1987-08       Impact factor: 5.948

7.  Effect of agitation and frequent subculturing on recovery of aerobic and facultative pathogens by Roche Septi-Chek and BACTEC blood culture systems.

Authors:  M J Kim; R L Gottschall; L D Schwabe; E L Randall
Journal:  J Clin Microbiol       Date:  1987-02       Impact factor: 5.948

8.  Controlled evaluation of the agar-slide and radiometric blood culture systems for the detection of bacteremia and fungemia.

Authors:  M P Weinstein; L B Reller; S Mirrett; C W Stratton; L G Reimer; W L Wang
Journal:  J Clin Microbiol       Date:  1986-02       Impact factor: 5.948

9.  Microbiological and clinical evaluation of the isolator lysis-centrifugation blood culture tube.

Authors:  N K Henry; C A McLimans; A J Wright; R L Thompson; W R Wilson; J A Washington
Journal:  J Clin Microbiol       Date:  1983-05       Impact factor: 5.948

10.  Comparative evaluation of Oxoid Signal and BACTEC radiometric blood culture systems for the detection of bacteremia and fungemia.

Authors:  M P Weinstein; S Mirrett; L B Reller
Journal:  J Clin Microbiol       Date:  1988-05       Impact factor: 5.948

View more
  12 in total

1.  Detection of bacteria in blood by centrifugation and filtration.

Authors:  M Bernhardt; D R Pennell; L S Almer; R F Schell
Journal:  J Clin Microbiol       Date:  1991-03       Impact factor: 5.948

2.  Methods used in the United Kingdom for the culture of micro-organisms from blood.

Authors:  D F Brown; S F Perry
Journal:  J Clin Pathol       Date:  1992-06       Impact factor: 3.411

3.  Effect of altered headspace atmosphere on yield and speed of detection of the Oxoid Signal blood culture system versus the BACTEC radiometric system.

Authors:  M P Weinstein; S Mirrett; L G Reimer; L B Reller
Journal:  J Clin Microbiol       Date:  1990-04       Impact factor: 5.948

Review 4.  Detection of bloodstream infections in children.

Authors:  J M Campos
Journal:  Eur J Clin Microbiol Infect Dis       Date:  1989-09       Impact factor: 3.267

5.  Comparison of the Oxoid Signal blood culture system with supplemented peptone broth in a pediatric hospital.

Authors:  C A Himmelreich; M F Orlando; G A Storch
Journal:  J Clin Microbiol       Date:  1989-06       Impact factor: 5.948

6.  Biographical Feature: Patrick R. Murray, Ph.D.

Authors:  Karen C Carroll
Journal:  J Clin Microbiol       Date:  2016-06-08       Impact factor: 5.948

7.  Comparative evaluation of nonradiometric BACTEC and improved oxoid signal blood culture systems in a clinical laboratory.

Authors:  C Daley; I Lim; J Modra; I Wilkinson
Journal:  J Clin Microbiol       Date:  1990-07       Impact factor: 5.948

Review 8.  Laboratory diagnosis of invasive candidiasis.

Authors:  J M Jones
Journal:  Clin Microbiol Rev       Date:  1990-01       Impact factor: 26.132

9.  Clinical comparison of the resin-containing BACTEC 26 Plus and the Isolator 10 blood culturing systems.

Authors:  J J Tarrand; C Guillot; M Wenglar; J Jackson; J D Lajeunesse; K V Rolston
Journal:  J Clin Microbiol       Date:  1991-10       Impact factor: 5.948

10.  Evaluation of two commercial blood culture media for the detection of blood-borne pathogens.

Authors:  P Rohner; B Pepey; R Auckenthaler
Journal:  Eur J Clin Microbiol Infect Dis       Date:  1994-01       Impact factor: 3.267

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.