Literature DB >> 33177787

An Investigation of Slot-scanning for Mammography and Breast CT.

Andrew F T Leong1, Grace J Gang1, Alejandro Sisniega1, Wenying Wang1, Jesse Wu1, Shabbir Bambot2, J Webster Stayman1.   

Abstract

Mammography and breast CT are important tools for breast cancer screening and diagnosis. Current implementations are limited by scattered radiation and/or spatial resolution. In this work, we propose and develop a slot scan-based system to be used in both mammography and CT mode that can limit scatter and collect sparse CT data for improved image quality at low radiation exposures. Monte Carlo simulations of an anthropomorphic breast phantom show a factor of 10 reduction in scattering amplitude with our slot scan-based system compared to that of a full-field detector mammography system (area mode). Similarly, slot-scan improved the MTF (particularly the low-frequency response) compared to an area detector. Investigation of sparse CT sampling with doubly sparse acquisition data return better quality reconstruction, for which our slot-scanning system is capable, over angle-only projection. Thus, a system with the combined ability for slot-scanning mammography and slot-scanning breast CT has the potential to deliver improved dose-efficient imaging performance and become viable breast cancer screening and diagnostic tools.

Entities:  

Keywords:  Breast cancer; CT; Compressed sensing; Mammography; Slot-scanning

Year:  2020        PMID: 33177787      PMCID: PMC7654952          DOI: 10.1117/12.2550200

Source DB:  PubMed          Journal:  Proc SPIE Int Soc Opt Eng        ISSN: 0277-786X


  8 in total

1.  Monotonic algorithms for transmission tomography.

Authors:  H Erdoğan; J A Fessler
Journal:  IEEE Trans Med Imaging       Date:  1999-09       Impact factor: 10.048

2.  A novel total variation based ring artifact suppression method for CBCT imaging with two-dimensional antiscatter grids.

Authors:  Timur Alexeev; Brian Kavanagh; Moyed Miften; Cem Altunbas
Journal:  Med Phys       Date:  2019-03-20       Impact factor: 4.071

3.  Algorithmic scatter correction in dual-energy digital mammography.

Authors:  Xi Chen; Robert M Nishikawa; Suk-tak Chan; Beverly A Lau; Lei Zhang; Xuanqin Mou
Journal:  Med Phys       Date:  2013-11       Impact factor: 4.071

4.  Monte Carlo study of the effects of system geometry and antiscatter grids on cone-beam CT scatter distributions.

Authors:  A Sisniega; W Zbijewski; A Badal; I S Kyprianou; J W Stayman; J J Vaquero; J H Siewerdsen
Journal:  Med Phys       Date:  2013-05       Impact factor: 4.071

5.  Development and Monte Carlo analysis of antiscatter grids for mammography.

Authors:  John M Boone; Olga V Makarova; Vladislav N Zyryanov; Cha-Mei Tang; Derrick C Mancini; Nikolaie Moldovan; Ralu Divan
Journal:  Technol Cancer Res Treat       Date:  2002-12

6.  Effect of screening mammography on breast-cancer mortality in Norway.

Authors:  Mette Kalager; Marvin Zelen; Frøydis Langmark; Hans-Olov Adami
Journal:  N Engl J Med       Date:  2010-09-23       Impact factor: 91.245

7.  SparseCT: System concept and design of multislit collimators.

Authors:  Baiyu Chen; Erich Kobler; Matthew J Muckley; Aaron D Sodickson; Thomas O'Donnell; Thomas Flohr; Bernhard Schmidt; Daniel K Sodickson; Ricardo Otazo
Journal:  Med Phys       Date:  2019-05-06       Impact factor: 4.071

8.  Effect of three decades of screening mammography on breast-cancer incidence.

Authors:  Archie Bleyer; H Gilbert Welch
Journal:  N Engl J Med       Date:  2012-11-22       Impact factor: 91.245

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.