Literature DB >> 12625771

Development and Monte Carlo analysis of antiscatter grids for mammography.

John M Boone1, Olga V Makarova, Vladislav N Zyryanov, Cha-Mei Tang, Derrick C Mancini, Nikolaie Moldovan, Ralu Divan.   

Abstract

Mammography arguably demands the highest fidelity of all x-ray imaging applications, with simultaneous requirements of exceedingly high spatial and contrast resolution. Continuing technical improvements of screen-film and digital mammography systems have led to substantial improvements in image quality, and therefore improvements in the performance of anti-scatter grids are required to keep pace with the improvements in other components of the imaging chain. The development of an air-core honeycomb (cellular) grid using x-ray lithography and electroforming techniques is described, and the production of a 60 mm x 60 mm section of grid is reported. A crossed grid was constructed with 25 microm copper septa, and a period of 550 microm. Monte Carlo and numerical simulation methods were used to analyze the theoretical performance of the fabricated grid, and comparisons with other grid systems (Lorad HTC and carbon fiber interspaced grids) were made over a range of grid ratios. The results demonstrate essentially equivalent performance in terms of contrast improvement factor (CIF) and Bucky factor (BF) between Cu and Au honeycomb grids and the Lorad HTC (itself a copper honeycomb grid). Gold septa improved both CIF and BF performance in higher kVp, higher scatter geometries. The selectivity of honeycomb grids was far better than for linear grids, with a factor of approximately 3.9 improvement at a grid ratio of 5.0. It is concluded that using the fabrication methods described, that practical honeycomb grid structures could be produced for use in mammographic imaging, and that a substantial improvement in scatter rejection would be achieved using these devices.

Entities:  

Mesh:

Year:  2002        PMID: 12625771     DOI: 10.1177/153303460200100604

Source DB:  PubMed          Journal:  Technol Cancer Res Treat        ISSN: 1533-0338


  4 in total

1.  The effect of scatter and glare on image quality in contrast-enhanced breast imaging using an a-Si/CsI(TI) full-field flat panel detector.

Authors:  Ann-Katherine Carton; Raymond Acciavatti; Johnny Kuo; Andrew D A Maidment
Journal:  Med Phys       Date:  2009-03       Impact factor: 4.071

2.  Mammographic artifacts on full-field digital mammography.

Authors:  Jae Jeong Choi; Sung Hun Kim; Bong Joo Kang; Byung Gil Choi; ByungJoo Song; Haijo Jung
Journal:  J Digit Imaging       Date:  2014-04       Impact factor: 4.056

3.  Design and evaluation of a grid reciprocation scheme for use in digital breast tomosynthesis.

Authors:  Tushita Patel; Helen Sporkin; Heather Peppard; Mark B Williams
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2016-03-29

4.  An Investigation of Slot-scanning for Mammography and Breast CT.

Authors:  Andrew F T Leong; Grace J Gang; Alejandro Sisniega; Wenying Wang; Jesse Wu; Shabbir Bambot; J Webster Stayman
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2020-03-16
  4 in total