| Literature DB >> 33134844 |
Carmen Maria Schönegger1, Sarah Gietl1, Bernhard Heinzle2, Kurt Freudenschuss3, Gernot Walder1.
Abstract
Smell and taste disorders are acknowledged as characteristic symptoms for SARS-CoV-2 infection by now. These symptoms have been linked to a neuroinvasive course of disease. In this study, we investigated five consecutive COVID-19 patients with a prolonged course of dysosmia and dysgeusia. Those with objectifiable alteration in taste or smell were subjected to MRI with contrast agent to investigate possible involvement of the central nervous system. We found dysosmia and dysgeusia to be mostly objectifiable, but no evidence for neuroinvasiveness could be detected by MRI in the late stage of the disease. Alterations in taste and smell could be objectified in most patients. Nevertheless, no evidence for a neuroinvasive potential could be identified by MRI, at least in the late stage of disease. We encourage medical professionals to conduct specialized examinations and MRIs in the acute stage of disease, which guarantees an optimum patient care. © Springer Nature Switzerland AG 2020.Entities:
Keywords: MRI; Neuoinvasive potential; Objective olfactory and gustatory testing; Smell and taste disorders
Year: 2020 PMID: 33134844 PMCID: PMC7585355 DOI: 10.1007/s42399-020-00606-4
Source DB: PubMed Journal: SN Compr Clin Med ISSN: 2523-8973
Results of the first gustatory and olfactory testing
| Olfactory testing | Gustatory testing | |
|---|---|---|
| Patient 1 | 4/12 | 4/4 |
| Patient 2 | 5/12 | 2/4 |
| Patient 3 | 6/12 | 0/4 |
| Patient 4 | 8/12 | 1/4 |
| Patient 5 | 12/12 | 4/4 |
Results of the second gustatory and olfactory testing
| Olfactory testing | Gustatory testing | |
|---|---|---|
| Patient 1 | 5/12 | 4/4 |
| Patient 2 | 10/12 | 4/4 |
| Patient 4 | 7/12 | 3/4 |
Image 1MRI axial T2
Image 2MRI Cor T1
Image 3MRI axial FLAIR
| Sequence | TR/TE (msec) | Flip angle degree | FOV (mm) | Matrix | Slice thickness (mm) | No of slices |
|---|---|---|---|---|---|---|
| T2W_TSE ax | 6608/107 | 90 | 230 × 185 × 170 | 384 × 240 | 5 | 27 |
| sT1W_3D_IR_TFE_tra | 9.4/4.6 | 8 | 250 × 198 × 145 | 252 × 199 | 1 | 145 |
| MPR COR | 70 | |||||
| MPR SAG | 55 | |||||
| FLAIR ax | 8000/130 | 90 | 230 × 186 × 153 | 272 × 144 | 4.5 | 28 |
| T2W_FFE ax | 877/23 | 20 | 230 × 180 × 148 | 260 × 145 | 4.5 | 25 |
| DWI | 3668/85 | 90 | 230 × 230 × 148 | 128 × 126 | 4.5 | 25 |
| KMT1W_3D_MPRAGE | 25/4.6 | 30 | 260 × 201 × 175 | 260 × 201 | 1 | 160 |
| KM MPR SAG | 50 | |||||
| KM MPR ax | 50 | |||||
| 3D_Brain_VIEW_FLAIR_COR | 4800/332 | 40 | 250 × 250 × 149 | 208 × 208 | 1.2 | 248 |
| 3D_Brain_VIEW_T2 | 2800/273 | 90 | 250 × 250 × 138 | 228 × 228 | 1.1 | 250 |