Literature DB >> 3310740

Systolic blood pressure variation is a sensitive indicator of hypovolemia in ventilated dogs subjected to graded hemorrhage.

A Perel1, R Pizov, S Cotev.   

Abstract

Systolic pressure variation (SPV) is defined as the difference between the maximum and minimum values of systolic blood pressure following a single positive pressure breath. An increase in the SPV is known to occur clinically during hypovolemia. This study aims to quantify SPV during graded hemorrhage in ventilated dogs, and to compare its reliability relative to other hemodynamic indicators of hypovolemia. Ten anesthetized dogs were mechanically ventilated with a fixed tidal volume. A continuously inflated vest was applied around the chest to maintain the ratio of lung to chest wall compliance similar to that of humans (0.83 +/- 0.12). SPV was further divided into delta up and delta down components relative to apneic (5 s) systolic blood pressure. Dogs were bled 5, 10, 20, and 30% of their estimated blood volume. The measured parameters best correlated to the amount of bleeding were SPV (rs = 0.993), delta down (rs = 0.981), and cardiac output (rs = 0.976). The SPV and its delta down component correlated to the degree of hemorrhage as well as the CO and the pulmonary capillary wedge pressure, and significantly better than the central venous pressure and the mean systemic blood pressure. Thus, SPV and its delta down component are accurate indicators of hypovolemia in ventilated dogs subjected to hemorrhage.

Entities:  

Mesh:

Year:  1987        PMID: 3310740     DOI: 10.1097/00000542-198710000-00009

Source DB:  PubMed          Journal:  Anesthesiology        ISSN: 0003-3022            Impact factor:   7.892


  66 in total

1.  Functional hemodynamic monitoring.

Authors:  Michael R Pinsky
Journal:  Intensive Care Med       Date:  2002-03-20       Impact factor: 17.440

2.  Arterial-line monitoring system simulation.

Authors:  D M Feinstein; D B Raemer
Journal:  J Clin Monit Comput       Date:  2000       Impact factor: 2.502

3.  Beat-to-beat blood pressure variability and patent ductus arteriosus in ventilated, premature infants.

Authors:  Alain Beuchée; Patrick Pladys; Lotfi Senhadji; Pierre Bétrémieux; François Carré
Journal:  Pflugers Arch       Date:  2003-03-27       Impact factor: 3.657

Review 4.  Fluid responsiveness in mechanically ventilated patients: a review of indices used in intensive care.

Authors:  Karim Bendjelid; Jacques-A Romand
Journal:  Intensive Care Med       Date:  2003-01-21       Impact factor: 17.440

5.  Systolic blood pressure at end-expiration measured by the automated systolic pressure variation monitor is equivalent to systolic blood pressure during apnea.

Authors:  H A Schwid; G A Rooke
Journal:  J Clin Monit Comput       Date:  2000       Impact factor: 2.502

6.  Monitoring of respiratory variations of aortic blood flow velocity using esophageal Doppler.

Authors:  Michel Slama; Henri Masson; Jean-Louis Teboul; Marie-Luce Arnould; Rachida Nait-Kaoudjt; Bouchra Colas; Marcel Peltier; Christophe Tribouilloy; Dinko Susic; Edward Frohlich; Michel Andréjak
Journal:  Intensive Care Med       Date:  2004-03-05       Impact factor: 17.440

Review 7.  Pulse pressure variation: where are we today?

Authors:  Maxime Cannesson; Mateo Aboy; Christoph K Hofer; Mohamed Rehman
Journal:  J Clin Monit Comput       Date:  2011-02       Impact factor: 2.502

8.  Pulse contour analysis guided management of a case of puerperal uterine inversion and hemorrhagic shock - 'Giving what it takes'.

Authors:  Shivinder Singh; A Kapur; R Goyal; A Joshi; S Pandith
Journal:  Med J Armed Forces India       Date:  2013-06-06

9.  The effect of tidal volume and intravascular volume state on systolic pressure variation in ventilated dogs.

Authors:  A Szold; R Pizov; E Segal; A Perel
Journal:  Intensive Care Med       Date:  1989       Impact factor: 17.440

10.  Pulse pressure variations to predict fluid responsiveness: influence of tidal volume.

Authors:  Daniel De Backer; Sarah Heenen; Michael Piagnerelli; Marc Koch; Jean-Louis Vincent
Journal:  Intensive Care Med       Date:  2005-03-08       Impact factor: 17.440

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.