Literature DB >> 33100059

Evaluation of Reference Metrics for Continuous Glucose Monitoring in Persons Without Diabetes and Prediabetes.

Sheyda Sofizadeh1,2, Anders Pehrsson3, Arndís F Ólafsdóttir1,2, Marcus Lind1,2.   

Abstract

BACKGROUND: Recent guidelines have been developed for continuous glucose monitoring (CGM) metrics in persons with diabetes. To understand what glucose profiles should be judged as normal in clinical practice and glucose-lowering trials, we examined the glucose profile of healthy individuals using CGM.
METHODS: Persons without diabetes or prediabetes were included after passing a normal oral glucose tolerance test, two-hour value <8.9 mmol/L (160 mg/dL), fasting glucose <6.1 mmol/L (110 mg/dL), and HbA1c <6.0% (<42 mmol/mol). CGM metrics were evaluated using the Dexcom G4 Platinum.
RESULTS: In total, 60 persons were included, mean age was 43.0 years, 70.0% were women, mean HbA1c was 5.3% (34 mmol/mol), and mean body mass index was 25.7 kg/m2. Median and mean percent times in hypoglycemia <3.9 mmol/L (70 mg/dL) were 1.6% (IQR 0.6-3.2), and 3.2% (95% CI 2.0; 4.3), respectively. For glucose levels <3.0 mmol/L (54 mg/dL), the corresponding estimates were 0.0% (IQR 0.0-0.4) and 0.5% (95% CI 0.2; 0.8). Median and mean time-in-range (3.9-10.0 mmol/L [70-180 mg/dL]) was 97.3% (IQR 95.4-98.7) and 95.4% (95% CI 94.0; 96.8), respectively. Median and mean standard deviations were 1.04 mmol/L (IQR 0.92-1.29) and 1.15 mmol/L (95% CI 1.05; 1.24), respectively. Measures of glycemic variability (standard deviation, coefficient of variation, mean amplitude of glycemic excursions) were significantly greater during daytime compared with nighttime, whereas others did not differ.
CONCLUSIONS: People without prediabetes or diabetes show a non-negligible % time in hypoglycemia, median 1.6% and mean 3.2%, which needs to be accounted for in clinical practice and glucose-lowering trials. Glycemic variability measures differ day and night in this population.

Entities:  

Keywords:  continuous glucose monitoring metrics; healthy population; hypoglycemia; time in range

Mesh:

Substances:

Year:  2020        PMID: 33100059      PMCID: PMC8861786          DOI: 10.1177/1932296820965599

Source DB:  PubMed          Journal:  J Diabetes Sci Technol        ISSN: 1932-2968


  33 in total

1.  A clinical trial of the accuracy and treatment experience of the Dexcom G4 sensor (Dexcom G4 system) and Enlite sensor (guardian REAL-time system) tested simultaneously in ambulatory patients with type 1 diabetes.

Authors:  Viktorija Matuleviciene; Jeffrey I Joseph; Mervi Andelin; Irl B Hirsch; Stig Attvall; Aldina Pivodic; Sofia Dahlqvist; David Klonoff; Börje Haraldsson; Marcus Lind
Journal:  Diabetes Technol Ther       Date:  2014-09-18       Impact factor: 6.118

2.  Accurate and precise isotope dilution mass spectrometry method for determining glucose in whole blood.

Authors:  U Hannestad; A Lundblad
Journal:  Clin Chem       Date:  1997-05       Impact factor: 8.327

3.  United Kingdom Prospective Diabetes Study (UKPDS). Effects of glucose and blood pressure control on complications of type 2 diabetes mellitus.

Authors:  C E Nasr; B J Hoogwerf; C Faiman; S S Reddy
Journal:  Cleve Clin J Med       Date:  1999-04       Impact factor: 2.321

4.  Validation of a new generation POCT glucose device with emphasis on aspects important for glycemic control in the hospital care.

Authors:  Snježana Kos; Arie van Meerkerk; Joke van der Linden; Theo Stiphout; Remi Wulkan
Journal:  Clin Chem Lab Med       Date:  2012       Impact factor: 3.694

5.  Accuracy of a Factory-Calibrated, Real-Time Continuous Glucose Monitoring System During 10 Days of Use in Youth and Adults with Diabetes.

Authors:  R Paul Wadwa; Lori M Laffel; Viral N Shah; Satish K Garg
Journal:  Diabetes Technol Ther       Date:  2018-06-14       Impact factor: 6.118

Review 6.  Clinical review: Realistic expectations and practical use of continuous glucose monitoring for the endocrinologist.

Authors:  Irl B Hirsch
Journal:  J Clin Endocrinol Metab       Date:  2009-04-21       Impact factor: 5.958

7.  Establishment of normal reference ranges for glycemic variability in Chinese subjects using continuous glucose monitoring.

Authors:  Jian Zhou; Hong Li; Xingwu Ran; Wenying Yang; Qiang Li; Yongde Peng; Yanbing Li; Xin Gao; Xiaojun Luan; Weiqing Wang; Weiping Jia
Journal:  Med Sci Monit       Date:  2011-01

8.  A Clinical Trial of the Accuracy and Treatment Experience of the Flash Glucose Monitor FreeStyle Libre in Adults with Type 1 Diabetes.

Authors:  Arndís F Ólafsdóttir; Stig Attvall; Ulrika Sandgren; Sofia Dahlqvist; Aldina Pivodic; Stanko Skrtic; Elvar Theodorsson; Marcus Lind
Journal:  Diabetes Technol Ther       Date:  2017-03-06       Impact factor: 6.118

9.  The use and efficacy of continuous glucose monitoring in type 1 diabetes treated with insulin pump therapy: a randomised controlled trial.

Authors:  T Battelino; I Conget; B Olsen; I Schütz-Fuhrmann; E Hommel; R Hoogma; U Schierloh; N Sulli; J Bolinder
Journal:  Diabetologia       Date:  2012-09-11       Impact factor: 10.122

10.  A Randomized Clinical Trial of the Effect of Continuous Glucose Monitoring on Nocturnal Hypoglycemia, Daytime Hypoglycemia, Glycemic Variability, and Hypoglycemia Confidence in Persons with Type 1 Diabetes Treated with Multiple Daily Insulin Injections (GOLD-3).

Authors:  Arndís F Ólafsdóttir; William Polonsky; Jan Bolinder; Irl B Hirsch; Sofia Dahlqvist; Hans Wedel; Thomas Nyström; Magnus Wijkman; Erik Schwarcz; Jarl Hellman; Tim Heise; Marcus Lind
Journal:  Diabetes Technol Ther       Date:  2018-04-02       Impact factor: 6.118

View more
  3 in total

1.  Glucose variability and predicted cardiovascular risk after gastrectomy.

Authors:  Jun Shibamoto; Takeshi Kubota; Takuma Ohashi; Hirotaka Konishi; Atsushi Shiozaki; Hitoshi Fujiwara; Kazuma Okamoto; Eigo Otsuji
Journal:  Surg Today       Date:  2022-03-31       Impact factor: 2.549

2.  Dysglycemia in adults at risk for or living with non-insulin treated type 2 diabetes: Insights from continuous glucose monitoring.

Authors:  Souptik Barua; Ashutosh Sabharwal; Namino Glantz; Casey Conneely; Arianna Larez; Wendy Bevier; David Kerr
Journal:  EClinicalMedicine       Date:  2021-04-25

3.  Risk factors, mortality trends and cardiovasuclar diseases in people with Type 1 diabetes and controls: A Swedish observational cohort study.

Authors:  Sara Hallström; Magnus Olof Wijkman; Johnny Ludvigsson; Per Ekman; Marc Alan Pfeffer; Hans Wedel; Annika Rosengren; Marcus Lind
Journal:  Lancet Reg Health Eur       Date:  2022-07-22
  3 in total