Accurate and precise isotope dilution mass spectrometry method for determining glucose in whole blood.

U Hannestad1, A Lundblad.   

Abstract

An accurate and precise method to determine glucose concentration in whole blood is presented. The method, based on isotope dilution gas chromatography-mass spectrometry (ID GC-MS), was developed to be used as a Reference Method for determining glucose concentration in capillary or venous whole blood. Blood samples and standards are pipetted manually with "microcap" micropipettes, which makes it possible to collect samples even at the patient's bedside. Glucose is quantified as its aldononitrile pentaacetate. [13C6]Glucose is used as an internal standard. Assay of Seronorm and Pathonorm L and H controls by ID GC-MS gave within-run CVs of 0.66%, 0.96%, and 0.92%, respectively. For whole blood with glucose concentrations in the low, normal, and high ranges, the within-run CVs were 1.27%, 0.91%, and 0.78%, respectively. The between-run CV for glucose calculated from 36 separate single analyses of Seronorm was 1.44%. In an accuracy assessment test of the HemoCue blood glucose analyzer, 140 capillary blood samples were measured in parallel after split-sampling. For all samples the HemoCue analyzer results had a mean bias of +2.0% compared with the ID GC-MS results.

Entities:  

Mesh:

Substances:

Year:  1997        PMID: 9166233

Source DB:  PubMed          Journal:  Clin Chem        ISSN: 0009-9147            Impact factor:   8.327


  16 in total

1.  Assessing the Accuracy of Continuous Glucose Monitoring (CGM) Calibrated With Capillary Values Using Capillary or Venous Glucose Levels as a Reference.

Authors:  Mervi Andelin; Jort Kropff; Viktorija Matuleviciene; Jeffrey I Joseph; Stig Attvall; Elvar Theodorsson; Irl B Hirsch; Henrik Imberg; Sofia Dahlqvist; David Klonoff; Börje Haraldsson; J Hans DeVries; Marcus Lind
Journal:  J Diabetes Sci Technol       Date:  2016-06-28

2.  Approaches for improving glucose monitor measurements for self-monitoring of blood glucose: from measurement harmonization to external quality assessment programs.

Authors:  Hubert W Vesper; Gary L Myers
Journal:  J Diabetes Sci Technol       Date:  2007-03

Review 3.  Glucose meters: a review of technical challenges to obtaining accurate results.

Authors:  Ksenia Tonyushkina; James H Nichols
Journal:  J Diabetes Sci Technol       Date:  2009-07-01

4.  A clinical trial of the accuracy and treatment experience of the Dexcom G4 sensor (Dexcom G4 system) and Enlite sensor (guardian REAL-time system) tested simultaneously in ambulatory patients with type 1 diabetes.

Authors:  Viktorija Matuleviciene; Jeffrey I Joseph; Mervi Andelin; Irl B Hirsch; Stig Attvall; Aldina Pivodic; Sofia Dahlqvist; David Klonoff; Börje Haraldsson; Marcus Lind
Journal:  Diabetes Technol Ther       Date:  2014-09-18       Impact factor: 6.118

5.  Glucose measurement: time for a gold standard.

Authors:  Joakim Hagvik
Journal:  J Diabetes Sci Technol       Date:  2007-03

6.  Application of the reference method isotope dilution gas chromatography mass spectrometry (ID/GC/MS) to establish metrological traceability for calibration and control of blood glucose test systems.

Authors:  Elisabeth Andreis; Kai Küllmer; Matthias Appel
Journal:  J Diabetes Sci Technol       Date:  2014-02-21

7.  Evaluation of Reference Metrics for Continuous Glucose Monitoring in Persons Without Diabetes and Prediabetes.

Authors:  Sheyda Sofizadeh; Anders Pehrsson; Arndís F Ólafsdóttir; Marcus Lind
Journal:  J Diabetes Sci Technol       Date:  2020-10-26

8.  Blood glucose measurements in the critically ill: more than just a blood draw.

Authors:  Frank M Brunkhorst; Hans G Wahl
Journal:  Crit Care       Date:  2006       Impact factor: 9.097

9.  Patients with coronary artery disease and diabetes need improved management: a report from the EUROASPIRE IV survey: a registry from the EuroObservational Research Programme of the European Society of Cardiology.

Authors:  Viveca Gyberg; Dirk De Bacquer; Guy De Backer; Catriona Jennings; Kornelia Kotseva; Linda Mellbin; Oliver Schnell; Jaakko Tuomilehto; David Wood; Lars Rydén; Philippe Amouyel; Jan Bruthans; Almudena Castro Conde; Renata Cifkova; Jaap W Deckers; Johan De Sutter; Mirza Dilic; Maryna Dolzhenko; Andrejs Erglis; Zlatko Fras; Dan Gaita; Nina Gotcheva; John Goudevenos; Peter Heuschmann; Aleksandras Laucevicius; Seppo Lehto; Dragan Lovic; Davor Miličić; David Moore; Evagoras Nicolaides; Raphael Oganov; Andrzej Pająk; Nana Pogosova; Zeljko Reiner; Martin Stagmo; Stefan Störk; Lale Tokgözoğlu; Dusko Vulic
Journal:  Cardiovasc Diabetol       Date:  2015-10-01       Impact factor: 9.951

10.  Effect of antecedent moderate-intensity exercise on the glycemia-increasing effect of a 30-sec maximal sprint: a sex comparison.

Authors:  Tara D Justice; Greta L Hammer; Raymond J Davey; Nirubasini Paramalingam; Kym J Guelfi; Lynley Lewis; Elizabeth A Davis; Timothy W Jones; Paul A Fournier
Journal:  Physiol Rep       Date:  2015-05
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.