Fully self-gated whole-heart 4D flow imaging from a 5-minute scan.

Aaron Pruitt1, Adam Rich1,2, Yingmin Liu3, Ning Jin4, Lee Potter2,3, Matthew Tong5, Saurabh Rajpal5, Orlando Simonetti3,5,6, Rizwan Ahmad1,2,3.   

Abstract

PURPOSE: To develop and validate an acquisition and processing technique that enables fully self-gated 4D flow imaging with whole-heart coverage in a fixed 5-minute scan. THEORY AND METHODS: The data are acquired continuously using Cartesian sampling and sorted into respiratory and cardiac bins using the self-gating signal. The reconstruction is performed using a recently proposed Bayesian method called ReVEAL4D. ReVEAL4D is validated using data from 8 healthy volunteers and 2 patients and compared with compressed sensing technique, L1-SENSE.
RESULTS: Healthy subjects-Compared with 2D phase-contrast MRI (2D-PC), flow quantification from ReVEAL4D shows no significant bias. In contrast, the peak velocity and peak flow rate for L1-SENSE are significantly underestimated. Compared with traditional parallel MRI-based 4D flow imaging, ReVEAL4D demonstrates small but significant biases in net flow and peak flow rate, with no significant bias in peak velocity. All 3 indices are significantly and more markedly underestimated by L1-SENSE. Patients-Flow quantification from ReVEAL4D agrees well with the 2D-PC reference. In contrast, L1-SENSE markedly underestimated peak velocity.
CONCLUSIONS: The combination of highly accelerated 5-minute Cartesian acquisition, self-gating, and ReVEAL4D enables whole-heart 4D flow imaging with accurate flow quantification.
© 2020 International Society for Magnetic Resonance in Medicine.

Entities:  

Keywords:  4D flow; Bayesian; CMR; Cartesian; phase-contrast; self-gating

Mesh:

Year:  2020        PMID: 32996625      PMCID: PMC7718421          DOI: 10.1002/mrm.28491

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  38 in total

1.  Generalized autocalibrating partially parallel acquisitions (GRAPPA).

Authors:  Mark A Griswold; Peter M Jakob; Robin M Heidemann; Mathias Nittka; Vladimir Jellus; Jianmin Wang; Berthold Kiefer; Axel Haase
Journal:  Magn Reson Med       Date:  2002-06       Impact factor: 4.668

2.  Self-gated cardiac cine MRI.

Authors:  Andrew C Larson; Richard D White; Gerhard Laub; Elliot R McVeigh; Debiao Li; Orlando P Simonetti
Journal:  Magn Reson Med       Date:  2004-01       Impact factor: 4.668

3.  An optimal radial profile order based on the Golden Ratio for time-resolved MRI.

Authors:  Stefanie Winkelmann; Tobias Schaeffter; Thomas Koehler; Holger Eggers; Olaf Doessel
Journal:  IEEE Trans Med Imaging       Date:  2007-01       Impact factor: 10.048

4.  Four-dimensional (4D) flow of the whole heart and great vessels using real-time respiratory self-gating.

Authors:  Sergio Uribe; Philipp Beerbaum; Thomas Sangild Sørensen; Allan Rasmusson; Reza Razavi; Tobias Schaeffter
Journal:  Magn Reson Med       Date:  2009-10       Impact factor: 4.668

5.  A method to correct background phase offset for phase-contrast MRI in the presence of steady flow and spatial wrap-around artifact.

Authors:  Aaron A Pruitt; Ning Jin; Yingmin Liu; Orlando P Simonetti; Rizwan Ahmad
Journal:  Magn Reson Med       Date:  2018-11-15       Impact factor: 4.668

6.  Sparsity transform k-t principal component analysis for accelerating cine three-dimensional flow measurements.

Authors:  Verena Knobloch; Peter Boesiger; Sebastian Kozerke
Journal:  Magn Reson Med       Date:  2012-08-06       Impact factor: 4.668

7.  Fast implementation for compressive recovery of highly accelerated cardiac cine MRI using the balanced sparse model.

Authors:  Samuel T Ting; Rizwan Ahmad; Ning Jin; Jason Craft; Juliana Serafim da Silveira; Hui Xue; Orlando P Simonetti
Journal:  Magn Reson Med       Date:  2016-04-05       Impact factor: 4.668

8.  Self-gated golden-angle spiral 4D flow MRI.

Authors:  Rene Bastkowski; Kilian Weiss; David Maintz; Daniel Giese
Journal:  Magn Reson Med       Date:  2018-01-17       Impact factor: 4.668

9.  5D whole-heart sparse MRI.

Authors:  Li Feng; Simone Coppo; Davide Piccini; Jerome Yerly; Ruth P Lim; Pier Giorgio Masci; Matthias Stuber; Daniel K Sodickson; Ricardo Otazo
Journal:  Magn Reson Med       Date:  2017-05-11       Impact factor: 4.668

Review 10.  Cardiovascular magnetic resonance phase contrast imaging.

Authors:  Krishna S Nayak; Jon-Fredrik Nielsen; Matt A Bernstein; Michael Markl; Peter D Gatehouse; Rene M Botnar; David Saloner; Christine Lorenz; Han Wen; Bob S Hu; Frederick H Epstein; John N Oshinski; Subha V Raman
Journal:  J Cardiovasc Magn Reson       Date:  2015-08-09       Impact factor: 5.364

View more
  3 in total

1.  Right and left ventricular function and flow quantification in pediatric patients with repaired tetralogy of Fallot using four-dimensional flow magnetic resonance imaging.

Authors:  Xiaofen Yao; Liwei Hu; Yafeng Peng; Fei Feng; Rongzhen Ouyang; Weihui Xie; Qian Wang; Aimin Sun; Yumin Zhong
Journal:  BMC Med Imaging       Date:  2021-10-31       Impact factor: 1.930

2.  Pilot tone navigation for respiratory and cardiac motion-resolved free-running 5D flow MRI.

Authors:  Mariana B L Falcão; Lorenzo Di Sopra; Liliana Ma; Mario Bacher; Jérôme Yerly; Peter Speier; Tobias Rutz; Milan Prša; Michael Markl; Matthias Stuber; Christopher W Roy
Journal:  Magn Reson Med       Date:  2021-10-05       Impact factor: 3.737

3.  Correlation between Pulmonary Artery Pressure and Vortex Duration Determined by 4D Flow MRI in Main Pulmonary Artery in Patients with Suspicion of Chronic Thromboembolic Pulmonary Hypertension (CTEPH).

Authors:  Jean-François Deux; Lindsey A Crowe; Léon Genecand; Anne-Lise Hachulla; Carl G Glessgen; Stéphane Noble; Maurice Beghetti; Jin Ning; Daniel Giese; Frédéric Lador; Jean-Paul Vallée
Journal:  J Clin Med       Date:  2022-09-05       Impact factor: 4.964

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.