Literature DB >> 19672940

Four-dimensional (4D) flow of the whole heart and great vessels using real-time respiratory self-gating.

Sergio Uribe1, Philipp Beerbaum, Thomas Sangild Sørensen, Allan Rasmusson, Reza Razavi, Tobias Schaeffter.   

Abstract

Four-dimensional (4D) flow imaging has been used to study flow patterns and pathophysiology, usually focused on specific thoracic vessels and cardiac chambers. Whole-heart 4D flow at high measurement accuracy covering the entire thoracic cardiovascular system would be desirable to simplify and improve hemodynamic assessment. This has been a challenge because compensation of respiratory motion is difficult to achieve, but it is paramount to limit artifacts and improve accuracy. In this work we propose a self-gating technique for respiratory motion-compensation integrated into a whole-heart 4D flow acquisition that overcomes these challenges. Flow components are measured in all three directions for each pixel over the complete cardiac cycle, and 1D volume projections are obtained at certain time intervals for respiratory gating in real time during the acquisition. The technique was tested in 15 volunteers, in which stroke volumes (SVs) in the great arteries showed excellent agreement with standard 2D phase-contrast (PC) scans. In contrast, nongated 4D flow with two averages had substantial disagreement with 2D flow. Applied to patients with congenital cardiac left-to-right shunting, the precision of flux data was highly beneficial. The methodology presented here has the potential to allow a complete study of flow pathophysiology of the thoracic cardiovascular system from a single free-breathing scan. (c) 2009 Wiley-Liss, Inc.

Entities:  

Mesh:

Year:  2009        PMID: 19672940     DOI: 10.1002/mrm.22090

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  45 in total

1.  In vivo and in vitro validation of aortic flow quantification by time-resolved three-dimensional velocity-encoded MRI.

Authors:  Fabian Rengier; Michael Delles; Roland Unterhinninghofen; Sebastian Ley; Matthias Müller-Eschner; Sasan Partovi; Philipp Geisbüsch; Rüdiger Dillmann; Hans-Ulrich Kauczor; Hendrik von Tengg-Kobligk
Journal:  Int J Cardiovasc Imaging       Date:  2012-02-24       Impact factor: 2.357

2.  Hemodynamic assessment in patients with one-and-a-half ventricle repair revealed by four-dimensional flow magnetic resonance imaging.

Authors:  Sergio Uribe; Pablo Bächler; Israel Valverde; Gérard R Crelier; Philipp Beerbaum; Cristian Tejos; Pablo Irarrazaval
Journal:  Pediatr Cardiol       Date:  2012-03-25       Impact factor: 1.655

Review 3.  Four-dimensional flow magnetic resonance imaging in cirrhosis.

Authors:  Zoran Stankovic
Journal:  World J Gastroenterol       Date:  2016-01-07       Impact factor: 5.742

4.  Four-dimensional phase contrast MRI with accelerated dual velocity encoding.

Authors:  Elizabeth J Nett; Kevin M Johnson; Alex Frydrychowicz; Alejandro Munoz Del Rio; Eric Schrauben; Christopher J Francois; Oliver Wieben
Journal:  J Magn Reson Imaging       Date:  2012-01-26       Impact factor: 4.813

5.  k-t accelerated aortic 4D flow MRI in under two minutes: Feasibility and impact of resolution, k-space sampling patterns, and respiratory navigator gating on hemodynamic measurements.

Authors:  Emilie Bollache; Alex J Barker; Ryan Scott Dolan; James C Carr; Pim van Ooij; Rouzbeh Ahmadian; Alex Powell; Jeremy D Collins; Julia Geiger; Michael Markl
Journal:  Magn Reson Med       Date:  2017-03-07       Impact factor: 4.668

Review 6.  Intracardiac flow visualization: current status and future directions.

Authors:  Daniel Rodriguez Muñoz; Michael Markl; José Luis Moya Mur; Alex Barker; Covadonga Fernández-Golfín; Patrizio Lancellotti; José Luis Zamorano Gómez
Journal:  Eur Heart J Cardiovasc Imaging       Date:  2013-08-01       Impact factor: 6.875

7.  Evaluation of blood flow distribution asymmetry and vascular geometry in patients with Fontan circulation using 4-D flow MRI.

Authors:  Kelly Jarvis; Susanne Schnell; Alex J Barker; Julio Garcia; Ramona Lorenz; Michael Rose; Varun Chowdhary; James Carr; Joshua D Robinson; Cynthia K Rigsby; Michael Markl
Journal:  Pediatr Radiol       Date:  2016-06-27

Review 8.  Important advances in technology and unique applications related to cardiac magnetic resonance imaging.

Authors:  Mohamad G Ghosn; Dipan J Shah
Journal:  Methodist Debakey Cardiovasc J       Date:  2014 Jul-Sep

9.  4D-MR flow analysis in patients after repair for tetralogy of Fallot.

Authors:  J Geiger; M Markl; B Jung; J Grohmann; B Stiller; M Langer; R Arnold
Journal:  Eur Radiol       Date:  2011-03-29       Impact factor: 5.315

10.  4-D flow magnetic resonance imaging: blood flow quantification compared to 2-D phase-contrast magnetic resonance imaging and Doppler echocardiography.

Authors:  Maya Gabbour; Susanne Schnell; Kelly Jarvis; Joshua D Robinson; Michael Markl; Cynthia K Rigsby
Journal:  Pediatr Radiol       Date:  2014-12-09
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.