Literature DB >> 22887065

Sparsity transform k-t principal component analysis for accelerating cine three-dimensional flow measurements.

Verena Knobloch1, Peter Boesiger, Sebastian Kozerke.   

Abstract

Time-resolved three-dimensional flow measurements are limited by long acquisition times. Among the various acceleration techniques available, k-t methods have shown potential as they permit significant scan time reduction even with a single receive coil by exploiting spatiotemporal correlations. In this work, an extension of k-t principal component analysis is proposed utilizing signal differences between the velocity encodings of three-directional flow measurements to further compact the signal representation and hence improve reconstruction accuracy. The effect of sparsity transform in k-t principal component analysis is demonstrated using simulated and measured data of the carotid bifurcation. Deploying sparsity transform for 8-fold undersampled simulated data, velocity root-mean-square errors were found to decrease by 52 ± 14%, 59 ± 11%, and 16 ± 32% in the common, external, and internal carotid artery, respectively. In vivo, errors were reduced by 15 ± 17% in the common carotid artery with sparsity transform. Based on these findings, spatial resolution of three-dimensional flow measurements was increased to 0.8 mm isotropic resolution with prospective 8-fold undersampling and sparsity transform k-t principal component analysis reconstruction. Volumetric data were acquired in 6 min. Pathline visualization revealed details of helical flow patterns partially hidden at lower spatial resolution.
Copyright © 2012 Wiley Periodicals, Inc.

Mesh:

Year:  2012        PMID: 22887065     DOI: 10.1002/mrm.24431

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  25 in total

1.  Highly accelerated aortic 4D flow MR imaging with variable-density random undersampling.

Authors:  Jing Liu; Petter Dyverfeldt; Gabriel Acevedo-Bolton; Michael Hope; David Saloner
Journal:  Magn Reson Imaging       Date:  2014-05-17       Impact factor: 2.546

Review 2.  4D flow imaging: current status to future clinical applications.

Authors:  Michael Markl; Susanne Schnell; Alex J Barker
Journal:  Curr Cardiol Rep       Date:  2014-05       Impact factor: 2.931

3.  A Bayesian approach for 4D flow imaging of aortic valve in a single breath-hold.

Authors:  Adam Rich; Lee C Potter; Ning Jin; Yingmin Liu; Orlando P Simonetti; Rizwan Ahmad
Journal:  Magn Reson Med       Date:  2018-09-28       Impact factor: 4.668

4.  Estimation of the CSA-ODF using Bayesian compressed sensing of multi-shell HARDI.

Authors:  Julio M Duarte-Carvajalino; Christophe Lenglet; Junqian Xu; Essa Yacoub; Kamil Ugurbil; Steen Moeller; Lawrence Carin; Guillermo Sapiro
Journal:  Magn Reson Med       Date:  2013-12-12       Impact factor: 4.668

5.  Influence of principal component analysis acceleration factor on velocity measurement in 2D and 4D PC-MRI.

Authors:  Gwenaël Pagé; Jérémie Bettoni; Anne-Virginie Salsac; Olivier Balédent
Journal:  MAGMA       Date:  2018-01-22       Impact factor: 2.310

6.  Highly accelerated intracranial 4D flow MRI: evaluation of healthy volunteers and patients with intracranial aneurysms.

Authors:  Jing Liu; Louise Koskas; Farshid Faraji; Evan Kao; Yan Wang; Henrik Haraldsson; Sarah Kefayati; Chengcheng Zhu; Sinyeob Ahn; Gerhard Laub; David Saloner
Journal:  MAGMA       Date:  2017-08-07       Impact factor: 2.310

7.  Accelerated phase contrast flow imaging with direct complex difference reconstruction.

Authors:  Aiqi Sun; Bo Zhao; Ke Ma; Zechen Zhou; Le He; Rui Li; Chun Yuan
Journal:  Magn Reson Med       Date:  2016-03-26       Impact factor: 4.668

8.  Free-breathing phase contrast MRI with near 100% respiratory navigator efficiency using k-space-dependent respiratory gating.

Authors:  Mehmet Akçakaya; Praveen Gulaka; Tamer A Basha; Long H Ngo; Warren J Manning; Reza Nezafat
Journal:  Magn Reson Med       Date:  2013-07-30       Impact factor: 4.668

9.  Improved acceleration of phase-contrast flow imaging with magnitude difference regularization.

Authors:  Taehoon Shin; Wanyong Shin
Journal:  Magn Reson Imaging       Date:  2019-12-02       Impact factor: 2.546

10.  A Bayesian model for highly accelerated phase-contrast MRI.

Authors:  Adam Rich; Lee C Potter; Ning Jin; Joshua Ash; Orlando P Simonetti; Rizwan Ahmad
Journal:  Magn Reson Med       Date:  2015-10-07       Impact factor: 4.668