Literature DB >> 32959080

Radiation dose management systems-requirements and recommendations for users from the ESR EuroSafe Imaging initiative.

Reinhard W Loose1,2, Eliseo Vano3, Peter Mildenberger4, Virginia Tsapaki5, Davide Caramella6, Johan Sjöberg7, Graciano Paulo8, Alberto Torresin9, Sebastian Schindera10, Guy Frija11, John Damilakis12.   

Abstract

The European Directive 2013/59/Euratom requires member states of the European Union to ensure justification and optimisation of radiological procedures and store information on patient exposure for analysis and quality assurance. The EuroSafe Imaging campaign of the European Society of Radiology created a working group (WG) on "Dose Management" with the aim to provide European recommendations on the implementation of dose management systems (DMS) in clinical practice. The WG follows Action 4: "Promote dose management systems to establish local, national, and European diagnostic reference levels (DRL)" of the EuroSafe Imaging Call for Action 2018. DMS are designed for medical practitioners, radiographers, medical physics experts (MPE) and other health professionals involved in imaging to support their tasks and duties of radiation protection in accordance with local and national requirements. The WG analysed requirements and critical points when installing a DMS and classified the individual functions at different performance levels. KEY POINTS: • DMS are very helpful software tools for monitoring patient exposure, optimisation, compliance with DRLs and quality assurance. • DMS can help to fulfil dosimetric aspects of the European Directive 2013/59/Euratom. • The EuroSafe WG analyses DMS requirements and gives recommendations for users.

Entities:  

Keywords:  Dose management systems; Optimisation; Quality assurance; Radiation protection

Mesh:

Year:  2020        PMID: 32959080      PMCID: PMC7979596          DOI: 10.1007/s00330-020-07290-x

Source DB:  PubMed          Journal:  Eur Radiol        ISSN: 0938-7994            Impact factor:   5.315


  1 in total

1.  Diagnostic reference levels and complexity indices in interventional radiology: a national programme.

Authors:  R Ruiz-Cruces; E Vano; F Carrera-Magariño; F Moreno-Rodriguez; M M Soler-Cantos; M Canis-Lopez; J Hernández-Armas; F J Diaz-Romero; F Rosales-Espizua; J M Fernandez-Soto; R Sanchez-Casanueva; A Martin-Palanca; M Perez-Martinez; A Gil-Agudo; M A Zarca-Diaz; V Parra-Osorio; J J Muñoz Ruiz-Canela; T Moreno-Sanchez; A Lopez-Medina; C Moreno-Saiz; P Galan-Montenegro; J J Gallego-Beuter; M Gonzalez-de-Garay; J C Zapata-Jimenez; J M Pastor-Vega; S Cañete
Journal:  Eur Radiol       Date:  2016-07-06       Impact factor: 5.315

  1 in total
  10 in total

1.  Challenges for managing the cumulative effective dose for patients.

Authors:  Eliseo Vano
Journal:  Br J Radiol       Date:  2020-09-30       Impact factor: 3.039

Review 2.  How to Measure/Calculate Radiation Dose in Patients?

Authors:  Reinhard Loose; Michael Wucherer
Journal:  Cardiovasc Intervent Radiol       Date:  2021-03-03       Impact factor: 2.740

3.  The importance of public health in radiology and radiation protection.

Authors:  Zuzana Bárdyová; Martina Horváthová; Katarína Pinčáková; Darina Budošová
Journal:  J Public Health Res       Date:  2021-03-12

4.  ESR EuroSafe Imaging and its role in promoting radiation protection - 6 years of success.

Authors:  Guy Frija; Christoph Hoeschen; Claudio Granata; Eliseo Vano; Graciano Paulo; John Damilakis; Lluis Donoso; Lorenzo Bonomo; Reinhard Loose; Steve Ebdon-Jackson
Journal:  Insights Imaging       Date:  2021-01-07

5.  Digital variance angiography allows about 70% decrease of DSA-related radiation exposure in lower limb X-ray angiography.

Authors:  Marcell Gyánó; Márton Berczeli; Csaba Csobay-Novák; Dávid Szöllősi; Viktor I Óriás; István Góg; János P Kiss; Dániel S Veres; Krisztián Szigeti; Szabolcs Osváth; Ákos Pataki; Viktória Juhász; Zoltán Oláh; Péter Sótonyi; Balázs Nemes
Journal:  Sci Rep       Date:  2021-11-08       Impact factor: 4.379

6.  Statement of the Italian Association of Medical Physics (AIFM) task group on radiation dose monitoring systems.

Authors:  Francesco Ria; Loredana D'Ercole; Daniela Origgi; Nicoletta Paruccini; Luisa Pierotti; Osvaldo Rampado; Veronica Rossetti; Sabina Strocchi; Alberto Torresin
Journal:  Insights Imaging       Date:  2022-02-05

7.  Paediatric diagnostic reference levels for common radiological examinations using the European guidelines.

Authors:  Anja Almén; Jónína Guðjónsdóttir; Nils Heimland; Britta Højgaard; Hanne Waltenburg; Anders Widmark
Journal:  Br J Radiol       Date:  2021-12-13       Impact factor: 3.039

Review 8.  Notifications and alerts in patient dose values for computed tomography and fluoroscopy-guided interventional procedures.

Authors:  Eliseo Vano; Reinhard Loose; Guy Frija; Graciano Paulo; Efstathios Efstathopoulos; Claudio Granata; Riccardo Corridori; Alberto Torresin; Jonas S Andersson; Virginia Tsapaki; Josefin Ammon; Christoph Hoeschen
Journal:  Eur Radiol       Date:  2022-03-16       Impact factor: 7.034

9.  Education and training in radiation protection in Europe: an analysis from the EURAMED rocc-n-roll project.

Authors:  Louise Rainford; Joana Santos; Francisco Alves; João Paulo Figueiredo; Christoph Hoeschen; John Damilakis; Guy Frija; Jonas Andersson; Jonathan McNulty; Shane Foley; Klaus Bacher; Ursula Nestle; Monika Hierath; Graciano Paulo
Journal:  Insights Imaging       Date:  2022-09-04

Review 10.  Dosimetric quantities and effective dose in medical imaging: a summary for medical doctors.

Authors:  Eliseo Vano; Guy Frija; Reinhard Loose; Graciano Paulo; Efstathios Efstathopoulos; Claudio Granata; Jonas Andersson
Journal:  Insights Imaging       Date:  2021-07-13
  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.