| Literature DB >> 32953123 |
Abstract
At the end of 2019, the novel coronavirus disease 2019 (COVID-19) emerged in Wuhan, China, then spread rapidly across the country and throughout the world. The causative agent is severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2); according to the International Committee on Taxonomy of Viruses, this virus has a nucleic acid sequence that is different from other known coronaviruses but has some similarity to the beta coronavirus identified in bats. Coronaviruses are a large virus group of enveloped positive-sense single-stranded RNA. They are divided into four genera-alpha, beta, delta and gamma-and alpha and beta coronaviruses are known to infect humans. Rapid and early diagnosis of COVID-19 is a challenging issue for physicians and other healthcare personnel. The sensitivity and specificity of the clinical, radiologic and laboratory tests used to diagnose COVID-19 are variable and largely differ in efficacy depending on the disease's stage of presentation.Entities:
Keywords: COVID-19; CRISPR; ELISA; LAMP; PCR; SARS-CoV-2; lateral flow immunoassay
Year: 2020 PMID: 32953123 PMCID: PMC7492157 DOI: 10.1016/j.nmni.2020.100761
Source DB: PubMed Journal: New Microbes New Infect ISSN: 2052-2975
Articles reporting on SARS-CoV-2 antigen testing
| Study (year) | Study design | Country | Antigen used | Methodology | Main findings or conclusions | Sensitivity | Specificity | PPV (%) | NPV (%) | |
|---|---|---|---|---|---|---|---|---|---|---|
| Mak (2020) [ | Retrospective | 368 | China | NA | Lateral flow IC | RAD was 103 fold less sensitive than virus culture; RAD was 105 fold less sensitive than RT-PCR. RAD detected 11.1% to 45.7% of RT-PCR–positive samples from COVID-19 patients. | NA | NA | NA | NA |
| Mertens (2020) [ | Retrospective | 328 pharyngeal samples | Belgium | Nucleoprotein | IC | COVID-19 Ag Respi-Strip represents a promising rapid SARS-CoV-2 antigen assay for first-line diagnosis of COVID-19 in 15 minutes at pandemic's peak. Its role in proposed diagnostic algorithm complements currently used molecular techniques. | 57.6 | 99.5 | 98.7 | 77.7 |
| Scohy (2020) [ | Retrospective | 148 nasopharyngeal samples | Belgium | Nucleoprotein | IC | Higher virus loads are associated with better antigen detection rates. Overall poor sensitivity of COVID-19 Ag Respi-Strip does not allow its use alone for frontline testing for COVID-19 diagnosis. | 30 | 100 | ||
| Blairon (2020) [ | Prospective | 774 | Belgium | Nucleoprotein | IC | Sensitivity of this rapid test is poor and improvements are needed to enhance its performance. | 23.9 | NA | NA | NA |
COVID-19, coronavirus disease 2019; IC, immunochromatography; NA, not available; NPV, negative predictive value; PPV, positive predictive value; RAD, rapid antigen test; RT-PCR, real-time PCR; SARS-CoV-2 = severe acute respiratory syndrome coronavirus 2.