Literature DB >> 9050414

An optimal rotator for iterative reconstruction.

J W Wallis, T R Miller.   

Abstract

For implementations of iterative reconstruction algorithms that rotate the image matrix, the characteristics of the rotator may affect the reconstruction quality. Desirable qualities for the rotator include: 1) preservation of global and local image counts; 2) accurate count positioning; 3) a uniform and predictable amount of blurring due to the rotation. A new rotation method for iterative reconstruction is proposed which employs. Gaussian interpolation. This method was compared to standard rotation techniques and is shown to be superior to standard techniques when measured by these qualities. The computational cost was demonstrated to be only slightly more than bilinear interpolation.

Mesh:

Year:  1997        PMID: 9050414     DOI: 10.1109/42.552061

Source DB:  PubMed          Journal:  IEEE Trans Med Imaging        ISSN: 0278-0062            Impact factor:   10.048


  9 in total

1.  Dosimetry for (177)Lu-DKFZ-PSMA-617: a new radiopharmaceutical for the treatment of metastatic prostate cancer.

Authors:  Andreas Delker; Wolfgang Peter Fendler; Clemens Kratochwil; Anika Brunegraf; Astrid Gosewisch; Franz Josef Gildehaus; Stefan Tritschler; Christian Georg Stief; Klaus Kopka; Uwe Haberkorn; Peter Bartenstein; Guido Böning
Journal:  Eur J Nucl Med Mol Imaging       Date:  2015-08-29       Impact factor: 9.236

2.  Use of three-dimensional Gaussian interpolation in the projector/backprojector pair of iterative reconstruction for compensation of known rigid-body motion in SPECT.

Authors:  Bing Feng; Howard C Gifford; Richard D Beach; Guido Boening; Michael A Gennert; Michael A King
Journal:  IEEE Trans Med Imaging       Date:  2006-07       Impact factor: 10.048

3.  Simulation of 4D spectral-spatial EPR images.

Authors:  Kang-Hyun Ahn; Howard J Halpern
Journal:  J Magn Reson       Date:  2007-03-01       Impact factor: 2.229

4.  Evaluation of Rigid-Body Motion Compensation in Cardiac Perfusion SPECT Employing Polar-Map Quantification.

Authors:  P Hendrik Pretorius; Karen L Johnson; Michael A King
Journal:  IEEE Trans Nucl Sci       Date:  2016-06-24       Impact factor: 1.679

5.  Range Condition and ML-EM Checkerboard Artifacts.

Authors:  Jiangsheng You; Jing Wang; Zhengrong Liang
Journal:  IEEE Trans Nucl Sci       Date:  2007-10       Impact factor: 1.679

6.  Fast and accurate rotator for rotation-based iterative reconstruction algorithms

Authors:  Krzysztof Kacperski; Jakub Pietrzak
Journal:  IEEE Nucl Sci Symp Conf Rec (1997)       Date:  2013-07-08

7.  Improvement of Performance of Cardiac SPECT Camera Using Curved Detectors With Pinholes.

Authors:  Joyoni Dey
Journal:  IEEE Trans Nucl Sci       Date:  2012-02-10       Impact factor: 1.679

8.  Simultaneous Tc-99m and I-123 dual-radionuclide imaging with a solid-state detector-based brain-SPECT system and energy-based scatter correction.

Authors:  Wataru Takeuchi; Atsuro Suzuki; Tohru Shiga; Naoki Kubo; Yuichi Morimoto; Yuichiro Ueno; Keiji Kobashi; Kikuo Umegaki; Nagara Tamaki
Journal:  EJNMMI Phys       Date:  2016-06-29

9.  Time-modified OSEM algorithm for more robust assessment of left ventricular dyssynchrony with phase analysis in ECG-gated myocardial perfusion SPECT.

Authors:  Matti J Kortelainen; Tuomas M Koivumäki; Marko J Vauhkonen; Mikko A Hakulinen
Journal:  EJNMMI Phys       Date:  2019-12-27
  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.