Physical aspects of a real-time tumor-tracking system for gated radiotherapy.

H Shirato1, S Shimizu, T Kunieda, K Kitamura, M van Herk, K Kagei, T Nishioka, S Hashimoto, K Fujita, H Aoyama, K Tsuchiya, K Kudo, K Miyasaka.   

Abstract

PURPOSE: To reduce uncertainty due to setup error and organ motion during radiotherapy of tumors in or near the lung, by means of real-time tumor tracking and gating of a linear accelerator. METHODS AND MATERIALS: The real-time tumor-tracking system consists of four sets of diagnostic X-ray television systems (two of which offer an unobstructed view of the patient at any time), an image processor unit, a gating control unit, and an image display unit. The system recognizes the position of a 2.0-mm gold marker in the human body 30 times per second using two X-ray television systems. The marker is inserted in or near the tumor using image guided implantation. The linear accelerator is gated to irradiate the tumor only when the marker is within a given tolerance from its planned coordinates relative to the isocenter. The accuracy of the system and the additional dose due to the diagnostic X-ray were examined in a phantom, and the geometric performance of the system was evaluated in 4 patients.
RESULTS: The phantom experiment demonstrated that the geometric accuracy of the tumor-tracking system is better than 1.5 mm for moving targets up to a speed of 40 mm/s. The dose due to the diagnostic X-ray monitoring ranged from 0.01% to 1% of the target dose for a 2.0-Gy irradiation of a chest phantom. In 4 patients with lung cancer, the range of the coordinates of the tumor marker during irradiation was 2.5-5.3 mm, which would have been 9.6-38.4 mm without tracking.
CONCLUSION: We successfully implemented and applied a tumor-tracking and gating system. The system significantly improves the accuracy of irradiation of targets in motion at the expense of an acceptable amount of diagnostic X-ray exposure.

Entities:  

Mesh:

Year:  2000        PMID: 11072178     DOI: 10.1016/s0360-3016(00)00748-3

Source DB:  PubMed          Journal:  Int J Radiat Oncol Biol Phys        ISSN: 0360-3016            Impact factor:   7.038


  110 in total

Review 1.  Lung cancer 5: state of the art radiotherapy for lung cancer.

Authors:  A Price
Journal:  Thorax       Date:  2003-05       Impact factor: 9.139

Review 2.  A review of image-guided radiotherapy.

Authors:  George T Y Chen; Gregory C Sharp; Shinichiro Mori
Journal:  Radiol Phys Technol       Date:  2008-12-16

3.  High-quality t2-weighted 4-dimensional magnetic resonance imaging for radiation therapy applications.

Authors:  Dongsu Du; Shelton D Caruthers; Carri Glide-Hurst; Daniel A Low; H Harold Li; Sasa Mutic; Yanle Hu
Journal:  Int J Radiat Oncol Biol Phys       Date:  2015-03-30       Impact factor: 7.038

Review 4.  Organ motion in image-guided radiotherapy: lessons from real-time tumor-tracking radiotherapy.

Authors:  Hiroki Shirato; Shinichi Shimizu; Kei Kitamura; Rikiya Onimaru
Journal:  Int J Clin Oncol       Date:  2007-02-25       Impact factor: 3.402

5.  Dynamic dual-energy chest radiography: a potential tool for lung tissue motion monitoring and kinetic study.

Authors:  Tong Xu; Justin L Ducote; Jerry T Wong; Sabee Molloi
Journal:  Phys Med Biol       Date:  2011-02-01       Impact factor: 3.609

6.  Lung tumor tracking in fluoroscopic video based on optical flow.

Authors:  Qianyi Xu; Russell J Hamilton; Robert A Schowengerdt; Brian Alexander; Steve B Jiang
Journal:  Med Phys       Date:  2008-12       Impact factor: 4.071

7.  Experimental investigation of a general real-time 3D target localization method using sequential kV imaging combined with respiratory monitoring.

Authors:  Byungchul Cho; Per Poulsen; Dan Ruan; Amit Sawant; Paul J Keall
Journal:  Phys Med Biol       Date:  2012-10-24       Impact factor: 3.609

8.  Dosimetric benefit of DMLC tracking for conventional and sub-volume boosted prostate intensity-modulated arc radiotherapy.

Authors:  Tobias Pommer; Marianne Falk; Per R Poulsen; Paul J Keall; Ricky T O'Brien; Peter Meidahl Petersen; Per Munck af Rosenschöld
Journal:  Phys Med Biol       Date:  2013-03-14       Impact factor: 3.609

9.  Determination of reproducibility of end-exhaled breath-holding in stereotactic body radiation therapy.

Authors:  Motoharu Sasaki; Hitoshi Ikushima; Kanako Sakuragawa; Michihiro Yokoishi; Akira Tsuzuki; Wataru Sugimoto
Journal:  J Radiat Res       Date:  2020-11-16       Impact factor: 2.724

10.  Management of three-dimensional intrafraction motion through real-time DMLC tracking.

Authors:  Amit Sawant; Raghu Venkat; Vikram Srivastava; David Carlson; Sergey Povzner; Herb Cattell; Paul Keall
Journal:  Med Phys       Date:  2008-05       Impact factor: 4.071

View more