Literature DB >> 32773914

System Modeling and Evaluation of a Prototype Inverted-Compound Eye Gamma Camera for the Second Generation MR Compatible SPECT.

Xiaochun Lai1, Elena M Zannoni2, Jonathan George1, Ling-Jian Meng1.   

Abstract

We have reported the design of the MRC-SPECT-II system based on the inverted-compound-eye (ICE) gamma camera to offer a > 1% detection efficiency while maintaining a sub-500 μm imaging resolution [1]. One of the key challenges of using the ICE camera for SPECT imaging is whether one could develop an accurate point response function (PRF), given its complex aperture design and low fractionation accuracy of 3D printing. In this work, we will discuss (I) a combined experimental and analytical approach for deriving the precise PRF, and (II) an experimental imaging study to demonstrate the feasibility of using the ICE-camera for acquiring high-quality SPECT images with a sub-500 μm resolution. These studies would help to overcome one of the major hurdles for implement ICE-cameras for practical SPECT imaging.

Entities:  

Keywords:  CdTe; Compound Eye; SPECT Modeling; SPECT/MRI

Year:  2019        PMID: 32773914      PMCID: PMC7405694          DOI: 10.1016/j.nima.2019.04.001

Source DB:  PubMed          Journal:  Nucl Instrum Methods Phys Res A        ISSN: 0168-9002            Impact factor:   1.455


  8 in total

1.  Characterization of pinhole SPECT acquisition geometry.

Authors:  Dirk Bequé; Johan Nuyts; Guy Bormans; Paul Suetens; Patrick Dupont
Journal:  IEEE Trans Med Imaging       Date:  2003-05       Impact factor: 10.048

2.  MRC-SPECT: A sub-500 μm resolution MR-compatible SPECT system for simultaneous dual-modality study of small animals.

Authors:  Liang Cai; Xiaochun Lai; Zengming Shen; Chin-Tu Chen; Ling-Jian Meng
Journal:  Nucl Instrum Methods Phys Res A       Date:  2014-01-11       Impact factor: 1.455

3.  Simultaneous compensation for attenuation, scatter and detector response for SPECT reconstruction in three dimensions.

Authors:  Z Liang; T G Turkington; D R Gilland; R J Jaszczak; R E Coleman
Journal:  Phys Med Biol       Date:  1992-03       Impact factor: 3.609

4.  Rapid additive manufacturing of MR compatible multipinhole collimators with selective laser melting of tungsten powder.

Authors:  Karel Deprez; Stefaan Vandenberghe; Karen Van Audenhaege; Jonas Van Vaerenbergh; Roel Van Holen
Journal:  Med Phys       Date:  2013-01       Impact factor: 4.071

5.  Simulation study of the second-generation MR-compatible SPECT system based on the inverted compound-eye gamma camera design.

Authors:  Xiaochun Lai; Ling-Jian Meng
Journal:  Phys Med Biol       Date:  2018-02-12       Impact factor: 3.609

6.  3D printing in X-ray and Gamma-Ray Imaging: A novel method for fabricating high-density imaging apertures.

Authors:  Brian W Miller; Jared W Moore; Harrison H Barrett; Teresa Fryé; Steven Adler; Joe Sery; Lars R Furenlid
Journal:  Nucl Instrum Methods Phys Res A       Date:  2011-12-10       Impact factor: 1.455

7.  A SPECT system simulator built on the SolidWorks TM 3D-Design package.

Authors:  Xin Li; Lars R Furenlid
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2014-08-17

8.  Development of clinical simultaneous SPECT/MRI.

Authors:  Brian F Hutton; Michele Occhipinti; Andre Kuehne; Domokos Máthé; Noémi Kovács; Helmar Waiczies; Kjell Erlandsson; Debora Salvado; Marco Carminati; Giovanni L Montagnani; Susan C Short; Luisa Ottobrini; Pieter van Mullekom; Claudio Piemonte; Tamas Bukki; Zoltan Nyitrai; Zoltan Papp; Kalman Nagy; Thoralf Niendorf; Irene de Francesco; Carlo Fiorini
Journal:  Br J Radiol       Date:  2017-03-07       Impact factor: 3.039

  8 in total
  3 in total

1.  Handling of uncertainty in medical data using machine learning and probability theory techniques: a review of 30 years (1991-2020).

Authors:  Roohallah Alizadehsani; Mohamad Roshanzamir; Sadiq Hussain; Abbas Khosravi; Afsaneh Koohestani; Mohammad Hossein Zangooei; Moloud Abdar; Adham Beykikhoshk; Afshin Shoeibi; Assef Zare; Maryam Panahiazar; Saeid Nahavandi; Dipti Srinivasan; Amir F Atiya; U Rajendra Acharya
Journal:  Ann Oper Res       Date:  2021-03-21       Impact factor: 4.820

2.  Applications of Machine Learning to Improve the Clinical Viability of Compton Camera Based in vivo Range Verification in Proton Radiotherapy.

Authors:  Jerimy C Polf; Carlos A Barajas; Stephen W Peterson; Dennis S Mackin; Sam Beddar; Lei Ren; Matthias K Gobbert
Journal:  Front Phys       Date:  2022-04-11

3.  Design Study of an Ultrahigh Resolution Brain SPECT System Using a Synthetic Compound-Eye Camera Design With Micro-Slit and Micro-Ring Apertures.

Authors:  Elena Maria Zannoni; Can Yang; Ling-Jian Meng
Journal:  IEEE Trans Med Imaging       Date:  2021-11-30       Impact factor: 10.048

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.