Literature DB >> 1565692

Simultaneous compensation for attenuation, scatter and detector response for SPECT reconstruction in three dimensions.

Z Liang1, T G Turkington, D R Gilland, R J Jaszczak, R E Coleman.   

Abstract

A three-dimensional reconstruction method for simultaneous compensation of attenuation, scatter and distance-dependent detector response for single photon emission computed tomography is described and tested by experimental studies. The method determines the attenuation factors recursively along each projection ray starting at the intersected source voxel closest to the detector. The method substracts the scatter energy window data from the primary energy window data for scatter compensation. The detector response is modelled to be spatially invariant at a constant distance from the detector. The method convolves source distribution with the modelled response function to compensate for the smoothed by use of a non-uniform entropy prior to searching for the maximum a posteriori probability solution. The method was tested using projections acquired from a chest phantom by a three-headed detector system with parallel hole collimators. An improvement was shown in image noise, recognition of object sizes and shapes, and quantification of concentration ratios.

Mesh:

Year:  1992        PMID: 1565692     DOI: 10.1088/0031-9155/37/3/007

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  12 in total

Review 1.  Dynamic single photon emission computed tomography--basic principles and cardiac applications.

Authors:  Grant T Gullberg; Bryan W Reutter; Arkadiusz Sitek; Jonathan S Maltz; Thomas F Budinger
Journal:  Phys Med Biol       Date:  2010-09-22       Impact factor: 3.609

2.  An Evaluation of Iterative Reconstruction Strategies on Mediastinal Lesion Detection Using Hybrid Ga-67 SPECT Images.

Authors:  N F Pereira; H C Gifford; P H Pretorius; T Farncombe; M Smyczynski; R Licho; P Schneider; M A King
Journal:  IEEE Nucl Sci Symp Conf Rec (1997)       Date:  2007

Review 3.  Technological development and advances in single-photon emission computed tomography/computed tomography.

Authors:  Youngho Seo; Carina Mari; Bruce H Hasegawa
Journal:  Semin Nucl Med       Date:  2008-05       Impact factor: 4.446

Review 4.  Quantitative myocardial perfusion SPECT.

Authors:  B M Tsui; E C Frey; K J LaCroix; D S Lalush; W H McCartney; M A King; G T Gullberg
Journal:  J Nucl Cardiol       Date:  1998 Sep-Oct       Impact factor: 5.952

Review 5.  Attenuation compensation for cardiac single-photon emission computed tomographic imaging: Part 2. Attenuation compensation algorithms.

Authors:  M A King; B M Tsui; T S Pan; S J Glick; E J Soares
Journal:  J Nucl Cardiol       Date:  1996 Jan-Feb       Impact factor: 5.952

6.  The Effects of Incorrect Modeling on Noise and Resolution Properties of ML-EM Images.

Authors:  D W Wilson; H H Barrett
Journal:  IEEE Trans Nucl Sci       Date:  2002-06       Impact factor: 1.679

7.  Contemporary Cardiac SPECT Imaging-Innovations and Best Practices: An Information Statement from the American Society of Nuclear Cardiology.

Authors:  Brian G Abbott; James A Case; Sharmila Dorbala; Andrew J Einstein; James R Galt; Robert Pagnanelli; Renée P Bullock-Palmer; Prem Soman; R Glenn Wells
Journal:  J Nucl Cardiol       Date:  2018-10       Impact factor: 5.952

8.  On Few-View Tomography and Staircase Artifacts.

Authors:  Gengsheng L Zeng
Journal:  IEEE Trans Nucl Sci       Date:  2015-02-23       Impact factor: 1.679

Review 9.  Scatter correction in scintigraphy: the state of the art.

Authors:  I Buvat; H Benali; A Todd-Pokropek; R Di Paola
Journal:  Eur J Nucl Med       Date:  1994-07

10.  Reconstruction from uniformly attenuated SPECT projection data using the DBH method.

Authors:  Qiu Huang; Jiangsheng You; Gengsheng L Zeng; Grant T Gullberg
Journal:  IEEE Trans Med Imaging       Date:  2009-01       Impact factor: 10.048

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.