Literature DB >> 32770491

Clinical outcomes after aphakic versus aphakic/pseudophakic intraoperative aberrometry in cataract surgery with toric IOL implantation.

Satish S Modi1.   

Abstract

PURPOSE: To determine if there was a clinically significant difference in clinical outcomes after toric IOL implantation based on intraoperative aberrometry (IA), where eyes were measured either in the aphakic state only or both the aphakic and pseudophakic states.
METHODS: A prospective, randomized, contralateral eye study was performed at one site in Poughkeepsie, NY, USA. Subjects included patients presenting for uncomplicated bilateral cataract surgery eligible for toric lens implantation with regular corneal astigmatism in both eyes whose toric IOL implantation was based on IA. One eye was measured when aphakic and the other when both aphakic and pseudophakic. The primary outcome measure was the magnitude of residual refractive astigmatism. Secondary measures included the percentage of eyes with 0.50D or less of residual refractive astigmatism, the spherical equivalent refraction and the time for IA measurement.
RESULTS: Mean residual refractive astigmatism was not statistically significantly different between groups (0.32D ± 0.46D IA_1 vs. 0.23D ± 0.35D IA_2, p = 0.25), nor was the percentage of eyes with a residual refractive cylinder of 0.50D or less (94% in both groups, p = 1.0). The average time to measure the pseudophakic eye was 3 min, 46 s. Aphakic IA measurements appeared to produce better spherical equivalent refractive results relative to preoperative calculations.
CONCLUSION: Pseudophakic IA measurements took nearly 4 min per case. Residual refractive astigmatism was not appreciably lower when pseudophakic IA measurements were made after aphakic IA measurements, which suggests aphakic IA measurements alone provide good clinical results with toric IOLs.

Entities:  

Keywords:  Astigmatism; Cylinder; Intraocular lens; ORA; Phacoemulsification; Time

Mesh:

Year:  2020        PMID: 32770491     DOI: 10.1007/s10792-020-01509-y

Source DB:  PubMed          Journal:  Int Ophthalmol        ISSN: 0165-5701            Impact factor:   2.031


  11 in total

1.  Anterior surface-based keratometry compared with Scheimpflug tomography-based total corneal astigmatism.

Authors:  Bastian Tonn; Oliver Klaus Klaproth; Thomas Kohnen
Journal:  Invest Ophthalmol Vis Sci       Date:  2014-12-02       Impact factor: 4.799

2.  Improving toric intraocular lens calculations using total surgically induced astigmatism for a 2.5 mm temporal incision.

Authors:  Jack T Holladay; George Pettit
Journal:  J Cataract Refract Surg       Date:  2018-12-07       Impact factor: 3.351

3.  Intraoperative aberrometry versus preoperative biometry for intraocular lens power selection in axial myopia.

Authors:  Darren C Hill; Shruti Sudhakar; Christopher S Hill; Tonya S King; Ingrid U Scott; Brett B Ernst; Seth M Pantanelli
Journal:  J Cataract Refract Surg       Date:  2017-04       Impact factor: 3.351

4.  Toric outcomes: Computer-assisted registration versus intraoperative aberrometry.

Authors:  Jonathan D Solomon; John Ladas
Journal:  J Cataract Refract Surg       Date:  2017-04       Impact factor: 3.351

5.  A large retrospective database analysis comparing outcomes of intraoperative aberrometry with conventional preoperative planning.

Authors:  Robert J Cionni; Ramon Dimalanta; Michael Breen; Cody Hamilton
Journal:  J Cataract Refract Surg       Date:  2018-08-10       Impact factor: 3.351

6.  Intraocular lens power selection and positioning with and without intraoperative aberrometry.

Authors:  Kathryn M Hatch; Emily C Woodcock; Jonathan H Talamo
Journal:  J Refract Surg       Date:  2015-04       Impact factor: 3.573

7.  Operating times of experienced cataract surgeons beginning femtosecond laser-assisted cataract surgery.

Authors:  Jordon G Lubahn; Kendall E Donaldson; William W Culbertson; Sonia H Yoo
Journal:  J Cataract Refract Surg       Date:  2014-09-10       Impact factor: 3.351

8.  New regression formula for toric intraocular lens calculations.

Authors:  Adi Abulafia; Douglas D Koch; Li Wang; Warren E Hill; Ehud I Assia; Maria Franchina; Graham D Barrett
Journal:  J Cataract Refract Surg       Date:  2016-05       Impact factor: 3.351

9.  Intraoperative aberrometry versus standard preoperative biometry and a toric IOL calculator for bilateral toric IOL implantation with a femtosecond laser: One-month results.

Authors:  Michael G Woodcock; Robert Lehmann; Robert J Cionni; Michael Breen; Maria C Scott
Journal:  J Cataract Refract Surg       Date:  2016-06       Impact factor: 3.351

10.  Refractive cylinder outcomes after calculating toric intraocular lens cylinder power using total corneal refractive power.

Authors:  James A Davison; Richard Potvin
Journal:  Clin Ophthalmol       Date:  2015-08-19
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.