Ca2+ is among the most important intracellular second messengers participating in a plethora of biological processes, and the measurement of Ca2+ fluctuations is significant in the phenomenology of the underlying processes. Aequorin-based Ca2+ probes represent an invaluable tool for reliable measurement of Ca2+ concentrations and dynamics in different subcellular compartments. However, their use is limited due to the lack on the market of ready-to-use, cost-effective, and portable devices for the detection and readout of the low-intensity bioluminescence signal produced by these probes. Silicon photomultipliers (SiPMs) are rapidly evolving solid-state sensors for low light detection, with single photon sensitivity and photon number resolving capability, featuring low cost, low voltage, and compact format. Thus, they may represent the sensors of choice for the development of such devices and, more in general, of a new generation of multipurpose bioluminescence detectors suitable for cell biology studies. Ideally, a detector customized for these purposes must combine high dynamic range with high fidelity in reconstructing the light intensity signal temporal profile. In this article, the ability to perform aequorin-based intracellular Ca2+ measurements using a multipurpose, low-cost setup exploiting SiPMs as the sensors is demonstrated. SiPMs turn out to assure performances comparable to those exhibited by a custom-designed photomultiplier tube-based aequorinometer. Moreover, the flexibility of SiPM-based devices might pave the way toward routinely and wide scale application of innovative biophysical protocols.
Ca2+ is among the most important intracellular second messengers participating in a plethora of biological processes, and the measurement of Ca2+ fluctuations is significant in the phenomenology of the underlying processes. Aequorin-based Ca2+ probes represent an invaluable tool for reliable measurement of Ca2+ concentrations and dynamics in different subcellular compartments. However, their use is limited due to the lack on the market of ready-to-use, cost-effective, and portable devices for the detection and readout of the low-intensity bioluminescence signal produced by these probes. Silicon photomultipliers (SiPMs) are rapidly evolving solid-state sensors for low light detection, with single photon sensitivity and photon number resolving capability, featuring low cost, low voltage, and compact format. Thus, they may represent the sensors of choice for the development of such devices and, more in general, of a new generation of multipurpose bioluminescence detectors suitable for cell biology studies. Ideally, a detector customized for these purposes must combine high dynamic range with high fidelity in reconstructing the light intensity signal temporal profile. In this article, the ability to perform aequorin-based intracellular Ca2+ measurements using a multipurpose, low-cost setup exploiting SiPMs as the sensors is demonstrated. SiPMs turn out to assure performances comparable to those exhibited by a custom-designed photomultiplier tube-based aequorinometer. Moreover, the flexibility of SiPM-based devices might pave the way toward routinely and wide scale application of innovative biophysical protocols.
Entities:
Keywords:
aequorin; bioluminescence; calcium signaling; live cell; silicon photomultipliers
Calcium (Ca2+) is
known to play a pivotal role in cell metabolism and signaling pathways,
both as one of the electrolytes responsible for membrane potential
and as an ubiquitous intracellular second messenger, able to activate
or modulate the activity of a plethora of proteins.[1] Cells continuously work to extrude calcium from cytosol
by both expelling it in the extracellular space and storing it within
suitable intracellular subcompartments including endoplasmic reticulum,
mitochondria, and lysosomes.[2] As a consequence
of these processes, cytosolic free calcium concentration ([Ca2+]c) is much lower than the typical extracellular
values (50–100 nM compared to 1.5–2 mM), thus making
Ca2+ signaling extremely effective and noiseless.[3] Both calcium influx from extracellular space
and/or release from internal stores can occur as a consequence of
the binding of specific membrane receptors with their ligands.[4] As a result, [Ca2+]c can
change following complex spatiotemporal dynamics, conveying information
coded in amplitude, frequency, and temporal profile of the signal[5,6] eventually mediating different functions in a cell-type-specific
way. Accordingly, [Ca2+]c is traditionally one
of the most investigated biophysical parameters to understand cell
physiology and pathology.Techniques for Ca2+ sensing
include fluorescence and
bioluminescence assays.[7,8] In particular, fluorescent synthetic
Ca2+ probes like Fura-2 and Fluo-4[9] have become popular due to their ease of use and the wide distribution
of fluorescent microscopes. On the other hand, genetically encoded
calcium indicators (GECIs) offer a reliable mean to detect and measure
Ca2+ in specific subcellular locations. These probes include
fluorescent probes (e.g., the GFP-derived GCaMP, and GeCO),[10−12] fluorescence resonance energy transfer (FRET)-based Ca2+ probes (e.g., cameleons and their analogues),[13,14] luminescent Ca2+ probes (e.g., AEQ-based indicators),
and bioluminescence resonance energy transfer (BRET)-based Ca2+ indicators (the last two reviewed in ref (15)). Among these techniques,
aequorin bioluminescence offers outstanding advantages.[8,16] Aequorin (AEQ) is a 21 kDa bioluminescent protein that can be used
as a calcium reporter without being externally excited. More in detail,
it is an enzyme that, upon the binding of three Ca2+ ions,
catalyzes the oxidation of its substrate coelenterazine, ultimately
producing a blue light emission (peaked at 465 nm):Many engineered aequorin variants are
currently available on the
market, and many different cell types can be transfected to make them
express aequorin at cytosolic level rather than just in some specific
subcellular organelles, such as mitochondria. In brief, aequorin represents
a natural calcium reporter, targetable, highly biocompatible, that
does not interfere with cell calcium homeostasis. Moreover, unlike
fluorescence, bioluminescence does not require any excitation light,
thus preserving cells from photodamage, while featuring a wide dynamic
range in emission. Despite all these indisputable advantages, typical
aequorin emission intensities are very low if compared to those of
fluorescent probes. Thus, extremely sensitive detectors are needed.
Overall, the lack of a ready-to-use commercial setup and the high
cost of specific-purpose custom-made detection systems (aequorinometers)
represent the main limitations to aequorin widespread use.Up
to now, photomultiplier tubes (PMTs) have been the detectors
of choice in aequorinometers because of their sensitivity up to the
single photon level. However, PMTs are bulky, relatively fragile,
and require biasing voltages in excess of 1 kV. In this regard, in
the last 20 years, a new generation of solid-state photodetectors,
known as silicon photomultipliers (SiPMs), has become commercially
available, and it is now increasingly being regarded as the most promising
competitor of PMTs.[17−19] SiPMs can produce a current pulse of several tens
of nanoseconds duration, containing millions of electrons in response
to the absorption of a single photon, thus providing a gain comparable
to that of PMTs in combination with all the benefits of a solid-state
sensor: single photon sensitivity, low-voltage operation, small size,
insensitivity to magnetic fields, mechanical robustness, and scalability.
Technology-wise, a SiPM is an array of p–n junctions (microcells)
operated in reverse bias mode beyond the breakdown voltage.[20−23] A SiPM can be operated in two modes: single photon counting (SPC)
and charge integration (CI).[24] SPC is more
suitable when the signal intensity is so low that the incoming photons
can be distinguished. Conversely, it is limited at high frequencies
by the superposition of single photon signals (pile-up). The pile-up
limit depends on the pulse duration of the SiPM output signal and
may be improved by properly shaping and filtering the native signal.
The pile-up probability increases exponentially as a function of the
impinging photons frequency, limiting the maximum detectable frequency
to a few megahertz. CI allows accessing the information related to
the charge collected in a time interval. Charge integration obviously
overcomes the problem of pile-up, showing sensibility also at high
frequencies, above 50 MHz. In this article, the ability to perform
aequorin-based intracellular Ca2+ gradient measurements
and time-course recordings exploiting SiPMs as sensors is demonstrated
using a multipurpose, low-cost setup in which the SPC and CI acquisition
modes are implemented in parallel to achieve the desired dynamic range
and sensitivity. Namely, the sensitivity, dynamic range, and linearity
of the system response are qualified on a simplified specimen consisting
in a lysate of aequorin-transfected cells. In addition, [Ca2+]c is monitored over time in AEQ-transfected HeLa cell
cultures stimulated by the paradigmatic agonist ATP by exploiting
both acquisition modalities.
Instrumentation, Materials,
and Methods
SiPM Sensor and Front-End Electronics
The measurements
presented in this work were performed using a HAMAMATSU S13360-6050CS
(https://www.hamamatsu.com/resources/pdf/ssd/s13360_series_kapd1052e.pdf) sensor, integrating 14,400 cells with 50 μm pitch, resulting
in a total area of 6 × 6 mm2. The detector features
a peak photon detection efficiency of 40% in the blue (i.e., aequorin
emission band), and it is characterized by an output-pulse full-time
development of 150 ns and dark-count rate (DCR) at the megahertz level
at room temperature (RT). The sensor was biased through the CAEN SP5600
power supply and amplification unit (PSAU; https://www.caen.it/products/sp5600e/).The SiPM output signal was amplified by a custom low-noise
and inverting amplifier featuring an AC-coupled high gain branch (34
dB) and a DC-coupled low gain one (20 dB). This latter was exploited
for the CI measurements, making the system sensitive to photon frequencies
so high that the baseline restoration is not possible, while the high
gain branch was used for the SPC modality. See the Supporting Information for the detailed specifics of the twin
gain amplifier and a schematic of the circuit (Figure S1).In order to enhance the SPC capability of
the system, the 34 dB
amplified signal was shortened by means of a zero-pole cancellation
circuit, reaching a full-time development of 30 ns (see ref (25) and the Supporting Information for further details). This corresponded
to a 5% probability of pile-up events at 2 MHz count rate assuming
a Poissonian temporal distribution of impinging photons. Then, the
signal was discriminated by a leading-edge comparator and pulses were
counted in 100 ms windows by a 16-bit scaler. Both the comparator
and the scaler are integrated within the PSAU. The leading-edge discriminator
threshold was set to 50% of the peak amplitude for a signal generated
by a single detected photon. The data were processed in real time
exploiting the SiPM kit control proprietary software provided by CAEN.For CI, the low gain branch of the amplifier was fed into an analog
integrator, namely, a CAEN V752N (https://www.caen.it/products/v792n/) charge-to-digital converter (QDC). The amplification factor and
the integration time were tuned (in the ranges 2.5x–10x and
4 μs–32 μs, respectively) to cope with the QDC
dynamic range. The sampling rate of the acquisition system was 11.2
kHz. Charge values were averaged over 5600 samples to increase sensitivity
and yield intensity vs time traces with the same time granularity
as those obtained by SPC.A block diagram summarizing the measurement
setup is depicted in Figure .
Figure 1
Block diagram of the SiPM-based experimental setup. The SiPM signal
is amplified by a two-branch, custom-made amplifier. On one hand,
the high gain branch (34 dB) is exploited for the SPC measurements.
Signal length is shortened through a pole-zero cancellation circuit,
and then each single photon pulse is counted through a leading-edge
discriminator and a counter hosted on the PSAU (power supply and amplifier
unit SP5600E by Caen S.p.A.). On the other hand, the low gain branch
(20 dB) is used to perform the CI measurements. The signal is directly
fed into a V752N analog integrator (Caen S.p.A.).
Block diagram of the SiPM-based experimental setup. The SiPM signal
is amplified by a two-branch, custom-made amplifier. On one hand,
the high gain branch (34 dB) is exploited for the SPC measurements.
Signal length is shortened through a pole-zero cancellation circuit,
and then each single photon pulse is counted through a leading-edge
discriminator and a counter hosted on the PSAU (power supply and amplifier
unit SP5600E by Caen S.p.A.). On the other hand, the low gain branch
(20 dB) is used to perform the CI measurements. The signal is directly
fed into a V752N analog integrator (Caen S.p.A.).
Sample to SiPM Interfacing
The SiPM sensor was mounted
on a dedicated holder featuring an external diameter of 5 cm. A steel
watertight chamber consisting of a base ring and a threaded insert
was used to mount the coverslip hosting the bioluminescent samples
(cell culture or cell lysate containing aequorin). Such a chamber
was then equipped with an injection system consisting of a flexible
tube to administer the chemicals of interest (i.e., Ca2+, ATP, and Triton X-100) and finally placed over the SiPM holder.
A black cap fitting the outer diameter of the SiPM holder was used
for covering both the sensor and the sample in order to protect them
from environmental light. All measurements were performed at RT, while
the SiPM temperature was constantly monitored through a thermistor
placed in contact with the external packaging of the sensor. The thermal
excursion observed during each single experiment was always within
0.5 °C.
Experimental Determination of Sensitivity
in Charge-Integration
Modality
To assess the minimum photoelectron rate detectable
in CI, a dedicated setup was devised. Illumination by a train of stochastically
impinging single-photon pulses, which best approaches the condition
occurring in the calcium sensing experiments, was mimicked as follows.
The SiPM was illuminated at stochastic time intervals by the light
pulses generated by a PLS-8-2-443 subnanosecond-pulsed LED (PicoQuant),
driven by the PDL 800-B driver (PicoQuant) used in the external trigger
mode. Stochastic triggers at different frequencies were obtained setting
a tunable threshold on a white-noise trace generated using a built-in
function in an Agilent 33250A waveform generator. The (Poisson) photon
number distribution of the LED pulses was measured at each threshold,
and the intensity was adjusted in order to have an average value of
1 photon per pulse. The amplified detector output signal was directly
fed into the QDC and integrated over 5 μs.
Cell Cultures
and Infection
Human cervical adenocarcinoma
cell line (HeLa, ATCC CCL-2) was cultured in complete DMEM medium
(Dulbecco’s modified Eagle’s medium, Sigma, Cat. D5671)
supplemented with 10% fetal bovine serum (FBS, Gibco, Cat. 10270),
2 mM glutamine (Sigma, Cat. G7513), 100 U/mL penicillin, and 0.1 mg/mL
streptomycin (Sigma, Cat. P0781). HeLa cells stably expressing cytosol-targeted
aequorin (cyt-RFP-AEQ) were generated by infecting 50,000 cells with
lentiviral particles at a multiplicity of infection (MOI) of 4–6.
After three passages, the cells expressing medium-high levels of cyt-RFP-AEQ
were enriched by fluorescence-activated cell sorting (FACS). After
amplification, the cyt-RFP-AEQ-expressing HeLa (HeLa-cyt-AEQ) were
stored in −80 °C until needed. Generation of lentiviral
cyt-RFP-AEQ construct and production of lentiviral particles and virus
titer definition were described elsewhere.[16]
Calcium Measurements on Cell Lysates
For cell lysate
preparation, HeLa-cyt-AEQ cells were grown in 100 mm culture dishes
(Falcon, Cat. 353003). At confluence, cells were washed twice in PBS
and scraped in 250 μL of a buffer containing (in mM): 150 Tris,
0.8 phenylmethylsulfonyl fluoride (PMSF), and 0.1 ethylenediaminetetraacetic
acid (EDTA), pH 7.2. After three cycles of freeze-thawing, cells were
centrifuged (12,000g, 5 min at 4 °C), the pellet
was discarded while the supernatant was aliquoted and stored at −80
°C.For AEQ reconstitution, 100 μL aliquots of HeLa-cyt-AEQ
lysate were supplemented with 140 mM β-mercaptoethanol (Sigma,
Cat. M6250) and 5 μM native coelenterazine (GoldBio, St. Luis,
MO, Cat. CZ5) and allowed to reconstitute O.N. (15–24 h) on
ice. For Ca2+ measurements, serial dilutions were prepared
in 150 mM Tris, supplemented with 10 mM EDTA, pH 7.2.For calcium
measurements, 500 μL of cell lysate was aliquoted
into the acquisition chamber. The latter was mounted on the top of
SiPM using optical grease to assure optimal matching of the refractive
index. After 30 s of acquisition, 1 mL of 150 mM Tris supplemented
with 50 mM CaCl2 was injected in the acquisition chamber.
After AEQ discharge, the trace was recorded until return to baseline
(about 4 min).
Calcium Measurements on Living Cultured Cells
For Ca2+ measurements in intact cells, HeLa-cyt-AEQ
expressing cells
were plated at decreasing densities (from 400,000 to 700 cells/well)
on 24 mm round glass coverslips in 6-well plates 24 h before the experiment.
In the day of measurements, cells were reconstituted with native coelenterazine
by adding the prosthetic group directly to the culture medium at 5
μM for 1–3 h. Coverslips with the reconstituted cells
were mounted in the acquisition chamber and placed on the top of SiPM
using optical grease. After 30 s of acquisition, an increase in intracellular
Ca2+ concentration was stimulated by injection of ATP (100
μM final concentration). Three to four minutes after ATP injection,
cells were disrupted by administration of 0.1% Triton X-100 in water
and residual active AEQ was discharged with 50 mM CaCl2. The acquisition continued until the trace returned to baseline.
Results
Response Linearity Assessment by Cell Lysates
The operational
dynamic range of the system was qualified in terms of the response
linearity using AEQ from cell lysate in order to exclude all those
possible sources of biological variability that are intrinsic to cell
culture samples. AEQ concentration was progressively diluted according
to a geometric progression of common ratio r = 2.
For each concentration, the same volume (500 μL) of sample was
used.Bioluminescence was measured in parallel with the two
techniques: SPC and CI. Regardless of the acquisition mode, traces
were subjected to baseline subtraction and the integrated luminescence
intensity (which is proportional to the total number of coelenterazine
oxidation reactions, thus to aequorin concentration) was computed.
In Figure , logarithmic
plots of integrated luminescence intensity versus concentration are
reported for CI (top) and SPC (bottom), respectively. The integrated
charge values have been converted into their corresponding values
expressed in photon counts by applying the conversion factor provided
by datasheets (i.e., 272 fC/photoelectron1)
in order to allow direct comparison between the two panels. For both
acquisition modalities, the representative trace acquired at a dilution
factor of 2–5 is also shown. It is also worth mentioning
that, at the lowest tested concentration value, a detectable signal
was observed only on the SPC branch.
Figure 2
Operational dynamic range of the system
qualified in terms of response
linearity. (A) The integrated intensity of the Ca2+ signal
(circles and crosses) is represented for both the acquisition modes
(CI and SPC) as a function of AEQ dilution factor. CI data are in
blue, while SPC data are in red. The inset shows SPC data points in
the linear scale to emphasize the deviation from linearity due to
pile-up phenomenon. In all the cases, crosses represent the data excluded
from the linear fit. (B) An example of trace recorded by CI is shown
for a dilution factor corresponding to 2–5. (C)
The same signal shown in (B), as seen from the SPC branch. Notice
how, at least in the superimposition region (from 2–6 to 2–3), the temporal profile of the signal is
faithfully reproduced by both the modalities.
Operational dynamic range of the system
qualified in terms of response
linearity. (A) The integrated intensity of the Ca2+ signal
(circles and crosses) is represented for both the acquisition modes
(CI and SPC) as a function of AEQ dilution factor. CI data are in
blue, while SPC data are in red. The inset shows SPC data points in
the linear scale to emphasize the deviation from linearity due to
pile-up phenomenon. In all the cases, crosses represent the data excluded
from the linear fit. (B) An example of trace recorded by CI is shown
for a dilution factor corresponding to 2–5. (C)
The same signal shown in (B), as seen from the SPC branch. Notice
how, at least in the superimposition region (from 2–6 to 2–3), the temporal profile of the signal is
faithfully reproduced by both the modalities.Because in the log–log scale a function of the type y = mx maps into a straight
line with the slope equal to a and intercept equal
to q = log (m), qualitative inspection
of the plots suggests that the response of the system is roughly linear
in both acquisition modalities over a concentration range spanning
more than three orders of magnitude (log10211 ≈ 3.31). Fitting the two plots to a linear model function
yields quantitative information on deviations from response linearity
as well as on sensitivity. Including all the data points in the fits
results in the slope values aCI = 1.107
± 0.030 and aSPC = 0.921 ± 0.027,
indicating that both acquisition modes are plagued by slight deviations.
Indeed, in the CI plot, the count value for the three points at lowest
concentrations is sizably underestimated compared to the corresponding
values determined in the SPC branch. This might be ascribed to insufficient
sensitivity of the CI mode in this concentration range. Excluding
these points from the linear regression results in a slope value aCI = 1.02 ± 0.04, compatible with data
linearity. Conversely, the slope obtained by fitting the whole SPC
dataset indicates a sublinear increase in counts with increasing AEQ
concentration, being the symptom of a phenomenon leading to saturation.
The latter is apparent in the linear scale, as shown in the inset
of Figure A. Excluding
the three points at highest concentrations from linear regression
yields a slope value compatible with data linearity, aSPC = 0.95 ± 0.05. As mentioned above, the intercepts
obtained by linear fit of the log–log plots quantify the sensitivity
of the two acquisition modes. Their values are qCI = 17.09 ± 0.34 and qSPC = 17.90 ± 0.20, respectively, for the fitting runs with three
excluded points, indicating comparable performances of the two modalities
in this respect, though with a slight superiority of SPC. Namely,
the quantity 2 = 1.75, where Δq = qSPC – qCI represents the ratio between the sensitivities of the
SPC and CI modes. In particular, this means that SPC is sensitive
to a minimum concentration roughly 2-fold lower than CI, in agreement
with experiments (see the point at [AEQ] = 2–10 in Figure A, which is detectable
only in the SPC mode).Once the ability of the system to quantify
the total amount of
AEQ discharged during a calcium gradient event was assessed, the accuracy
in reproducing the gradient temporal profile was taken into account.
The first figure of merit evaluated to this aim was the reliability
in retrieving the signal peak value. In the logarithmic plot of Figure , the peak frequency
values detected in the SPC (red) and CI (blue) branches are reported
as a function of concentration. The tendency of SPC data to saturate
at high concentrations is much more evident than in the integral intensity
plot. Inspection of oscilloscope screenshots of the pulse trains at
the amplifier output shows a significant pile-up above ≈3 MHz
(see exemplary traces reproduced in Figure ). This phenomenon also contributes to the
deviations from linearity observed in the plots of the Ca2+ signal-integrated intensity, although in the latter instance, it
is mitigated by the fact that only the few time points around the
peak are significantly affected (see Supporting Information, Figure S4 for a comparison of the traces acquired
in CI and SPC branches in this concentration range). Moreover, the
CI mode successfully determines the peak values even in the concentration
range in which it was unable to assess accurate values of the integrated
intensity (i.e., for the three lowest-concentration data points).
This stems in support of the argument that the pitfalls of CI are
connected to ultimate sensitivity (limit of detection, LoD) lower
than SPC. In any case, the correct assessment of the peak values does
not correspond to faithful reproduction of the Ca2+ signal
temporal profile, as made apparent by direct comparison of the traces
in the CI and SPC branches in this concentration range (see Supporting
Informatio, Figure S5). More details about
the pile-up effect and the limitations of both the modalities are
reported in ref (25).
Figure 3
Assessment of the temporal-profile reconstruction capabilities.
The Ca2+ signal peak frequency values detected in SPC (red)
and CI (blue) are reported as a function of AEQ concentration in the
log–log plot. On the right, two oscilloscope screenshots at
two different concentrations show how the highest concentrations are
affected by pile-up. In the screenshots, the green signal is referred
to the SiPM output, while the yellow one is the output of the discriminator,
which provides the information for the SPC mode.
Assessment of the temporal-profile reconstruction capabilities.
The Ca2+ signal peak frequency values detected in SPC (red)
and CI (blue) are reported as a function of AEQ concentration in the
log–log plot. On the right, two oscilloscope screenshots at
two different concentrations show how the highest concentrations are
affected by pile-up. In the screenshots, the green signal is referred
to the SiPM output, while the yellow one is the output of the discriminator,
which provides the information for the SPC mode.In conclusion, the simultaneous recording in SPC and CI modes highlights
the advantages and disadvantages of the two approaches: while the
QDC series show a reduced sensitivity at low concentrations essentially
because of residual baseline fluctuations, counting modality results
unsuitable for high aequorin concentrations due to the pile-up of
the incoming pulses.
Experimental Determination of the Limit of
Detection in Photon-Counting
and Charge-Integration Modes
Since the LoD is a crucial parameter
in the assessment of the instrument, its value was experimentally
measured for both acquisition modes. In the SPC mode, the minimum
detectable rate can be estimated by assuming the noise being solely
due to DCR and obeying a Poisson statistics. For our detector kept
in the dark, the average DCR was measured to be (904 ± 3) kHz.
A representative DCR trace is shown in Figure , together with the pertaining frequency
histogram. Defining the LoD as 3σDCR, we get 9 kHz,
which coincides with that theoretically expected for a Poisson distribution
of noise fluctuations assuming a sampling time Δt = 100 ms, as shown by the calculation below:
Figure 4
Dark-count
rate (DCR) in the SPC mode. Left: an exemplary noise
trace (blue line), recorded in the SPC mode. The two orange lines
represent the experimental LoD limit that corresponds to ≈9
kHz. Right: the pertaining frequency histogram, showing a DCR level
of (904 ± 3) kHz.
Dark-count
rate (DCR) in the SPC mode. Left: an exemplary noise
trace (blue line), recorded in the SPC mode. The two orange lines
represent the experimental LoD limit that corresponds to ≈9
kHz. Right: the pertaining frequency histogram, showing a DCR level
of (904 ± 3) kHz.The experimentally measured
DCR can also be exploited to estimate
the theoretical LoD in the CI mode. For the integration gate Δt = 5 μs used in the experiments, eq yields an LoD value of 1.27 MHz.
To quest this result, a dedicated measurement was performed. The dark
current of the biased SiPM was measured within an integration gate
of 5 μs. Subsequently, the SiPM was illuminated by a stochastic
Poissonian light generated as detailed in Instrumentation,
Materials, and Methods (see the Experimental
Determination of Sensitivity in Charge-Integration Modality section). By increasing the pulse frequency, it was possible to
assess the minimum frequency of incoming photons that could be discriminated
from the noise. As shown in Figure A, the LoD resulted to be ≈2 MHz, possibly because
of baseline fluctuations due to the amplifying stage. Setting a time
granularity equal to the one used in the measurements performed on
lysate (2 Hz) allowed averaging over a sample of 5600 consecutive
events, thus reducing the LoD to ≈55 kHz (Figure B,D). It is worth mentioning
that the improvement in LoD induced by averaging is lower than that
expected assuming a Poisson distribution for the noise (i.e., ). Moreover, the LoD determined in the case
of CI is higher than that measured for SPC by a factor 6.1, confirming
that the photon-counting approach is more suitable for the detection
of feeble signals. Finally, it should be taken into account that the
SPC acquisition mode is in principle able to attain the same LoD as
the CI mode by data sampling over a time ≈40-fold shorter,
which might be crucial to reconstruct the temporal profile of very
fast Ca2+ transients.
Figure 5
LoD assessment for the CI mode. (A) Charge
distribution recorded
in CI: in blue, the dark current of the biased SiPM (amplifier noise
+ SiPM DCR), the blue line is the mean value (μ), while the
two dashed lines are the LoD reported as μ ± 3σDCR in an integration gate of 5 μs. In orange, the current
due to the Poissonian light generated at a frequency of 2053 kHz is
shown with the red line corresponding to its mean value. (B) Similarly,
with a light frequency of 55 kHz. In (C) and (D), the current distributions
after averaging over 5600 events are shown for 2053 and 55 kHz, respectively.
LoD assessment for the CI mode. (A) Charge
distribution recorded
in CI: in blue, the dark current of the biased SiPM (amplifier noise
+ SiPM DCR), the blue line is the mean value (μ), while the
two dashed lines are the LoD reported as μ ± 3σDCR in an integration gate of 5 μs. In orange, the current
due to the Poissonian light generated at a frequency of 2053 kHz is
shown with the red line corresponding to its mean value. (B) Similarly,
with a light frequency of 55 kHz. In (C) and (D), the current distributions
after averaging over 5600 events are shown for 2053 and 55 kHz, respectively.
Live-Cell Recording by QDC
A first
series of experiments
using intact HeLa cells was carried out recording bioluminescent signals
from cell populations in the CI mode. A sampling time of 5 μs
was used, and the traces were averaged over 1000 points. Cells were
plated at different densities, from 100,000 to 25,000 cells/well (see Figure B). ATP, commonly
used in calcium experiments for testing cell viability, was chosen
as a prototypical agonist because of its capability to elicit a wide
range of intracellular calcium signals, through both direct (e.g.,
purinergic) and indirect pathways, in an almost reproducible way.
When injected, ATP induced a transient increase in luminescence, expression
of the change in [Ca2+]c (Figure A, red circles and insets). Normally, such
a [Ca2+]c increase was no more detectable after
1–2 min from ATP administration, in that the corresponding
charge signal was again indistinguishable from the baseline value.
After 3 min from the beginning of the experiment, 1 mL of Triton X-100
was injected into the chamber in order to destroy cell membranes and
completely oxidize the total amount of coelenterazine by aequorin
activity upon extracellular calcium binding. Experiments stopped after
7–8 min of total recording, a time long enough for capturing
the entire signal elicited by Triton X-100 (Figure A). In order to assess the SiPM system performance,
SiPM traces were compared to those recorded in similar experimental
conditions by exploiting a custom-designed PMT-based aequorinometer
produced by Cairn Research (UK), which is fully described in the Supporting
Information (Figure S6). On a qualitative
standpoint, the traces obtained by the two detection devices were
comparable (see Figure C for exemplary aequorinometer traces). To obtain a quantitative
comparison, the integral intensities of the ATP and Triton X-100 signals
were separately evaluated after baseline subtraction and their average
ratio A/T was computed as a figure
of merit. Statistically compliant values, A/TQDC = 0.039 ± 0.005 and A/TPMT = 0.032 ± 0.009, were obtained
for the SiPM- and the PMT-based systems, respectively. This feature
indicates that the integrated charge by the SiPM provides an accurate
recording of the light emitted in correspondence of membrane lysis
at all the tested cell densities, without saturation onset.
Figure 6
Bioluminescence
signals from AEQ-transfected HeLa cells, recorded
through QDC. (A) Three exemplificative traces of bioluminescence time
courses recorded by CI and corresponding to plating densities of 100
× 103, 50 × 103, and 25 × 103 cells/well respectively. For each trace, response to 100
μM ATP is circled in red and magnified in the upper-left inset.
The higher subsequent peak represents the luminescent signal induced
by Triton X-100. Notice the extreme dynamic range (from 5 to 1800
ADC channels) featured by the system. (B) Phase-contrast images of
cultured HeLa cells used for bioluminescence recording. Each optical
field is representative of the particular plating densities indicated
above. (C) Three exemplificative traces of bioluminescence time courses
as recorded by a PMT-based aequorinometer, corresponding to the same
plating densities used in SiPM+QDC experiments (100 × 103, 50 × 103, and 25 × 103 cells/well
respectively). Even in this case, response to 100 μM ATP is
circled in red and magnified in the upper-left inset, while the subsequent
peak is the consequence of Triton X-100-induced membrane lysis.
Bioluminescence
signals from AEQ-transfected HeLa cells, recorded
through QDC. (A) Three exemplificative traces of bioluminescence time
courses recorded by CI and corresponding to plating densities of 100
× 103, 50 × 103, and 25 × 103 cells/well respectively. For each trace, response to 100
μM ATP is circled in red and magnified in the upper-left inset.
The higher subsequent peak represents the luminescent signal induced
by Triton X-100. Notice the extreme dynamic range (from 5 to 1800
ADC channels) featured by the system. (B) Phase-contrast images of
cultured HeLa cells used for bioluminescence recording. Each optical
field is representative of the particular plating densities indicated
above. (C) Three exemplificative traces of bioluminescence time courses
as recorded by a PMT-based aequorinometer, corresponding to the same
plating densities used in SiPM+QDC experiments (100 × 103, 50 × 103, and 25 × 103 cells/well
respectively). Even in this case, response to 100 μM ATP is
circled in red and magnified in the upper-left inset, while the subsequent
peak is the consequence of Triton X-100-induced membrane lysis.
Live-Cell Recording in the Photon-Counting
Mode
In
order to explore the possibility of detecting extremely low-intensity
signals, similar experiments were carried out in the SPC modality.
Through this configuration, it has been possible to detect ATP-induced
calcium signals in a wide range of plating density conditions, down
to 700 cells/well. An exemplary trace is shown in Figure A. Occasionally, also tiny
(less than 50 kHz) spontaneous [Ca2+]c oscillations
could be recorded prior to ATP administration (Figure B).
Figure 7
Bioluminescence signals from intact cyt- and
mit-AEQ-transfected
HeLa cells, recorded through PSAU discriminator in the photon-counting
mode. (A) Representative frequency vs time trace corresponding to
a plating density of 3000 cells/well. ATP (100 μM) and Triton
X-100 signals are labeled in black. (B) Magnification of the gray
dashed rectangle in (A) showing spontaneous calcium oscillations.
The fact that these signals were completely abolished by ATP administration
further confirms their biological, i.e., non-instrumental, origin.
(C) Representative trace of ATP-induced [Ca2+]m increases recorded from a cell culture sample at a plating density
of 200,000 cells/well.
Bioluminescence signals from intact cyt- and
mit-AEQ-transfected
HeLa cells, recorded through PSAU discriminator in the photon-counting
mode. (A) Representative frequency vs time trace corresponding to
a plating density of 3000 cells/well. ATP (100 μM) and Triton
X-100 signals are labeled in black. (B) Magnification of the gray
dashed rectangle in (A) showing spontaneous calcium oscillations.
The fact that these signals were completely abolished by ATP administration
further confirms their biological, i.e., non-instrumental, origin.
(C) Representative trace of ATP-induced [Ca2+]m increases recorded from a cell culture sample at a plating density
of 200,000 cells/well.Spontaneous calcium oscillations
are important and ubiquitous calcium-based
signaling mechanisms. Like other calcium signals, oscillations depend
on the cell expression of a sophisticated protein “toolkit”
for membrane transport of calcium ion, such as ion channels, transporters,
and pumps.[3] Their generation is often the
result of a coordinated interplay between a calcium release from intracellular
stores and a calcium influx across the plasma membrane controlled
by Ca2+ itself or by an increasing number of intracellular
messengers.[3,26] A large amount of studies indicate
that spontaneous oscillations control a plethora of fundamental cell
programs, such as fertilization, migration, differentiation, and maturation.[3,27] In particular, in HeLa cells, spontaneous calcium oscillations with
a behavior similar to the one showed in Figure B are thought to play a role in driving cells
through the different stages of the cell-division cycle.[28]One of the key features of AEQ-based Ca2+ probes is
the ability to measure [Ca2+] in different subcellular
locations.[16,29] To prove that SiPM is also suitable
to detect Ca2+ signals from an AEQ probe targeted to an
intracellular organelle, we transfected HeLa cells with AEQ targeted
to the mitochondrial matrix (mit-AEQ).[16]Figure C shows that
the ATP-induced [Ca2+]c increase induced Ca2+ uptake by mitochondria[30] with
a robust elevation of [Ca2+] in the mitochondrial matrix
([Ca2+]m). The dynamics of this elevation closely
resembled that of mit-AEQ traces recorded using conventional aequorinometer
setups.[16,29] The trace peaked at 2200 kHz, which was
far below the pile-up threshold (≈3100 kHz, Figure ). In this experiment, a cell
density of 200,000 cells/coverslip was used, indicating that the desired
intensity of the signal can be easily obtained by downscaling the
number of plated cells.In general, as already stated with respect
to linearity assessment,
this front-end configuration featured the highest sensitivity (Figure ), but it also proved
to suffer from extensive pile-up, leading in turn to an event miscounting
above 3 MHz (Figure ). In particular, during the Ca2+ response elicited by
Triton X-100, the system experienced extreme pile-up, while ATP-induced
and spontaneous signals were correctly counted even at their peak
amplitudes. As expected, the poor dynamic range of this configuration
led to a significant increase in the A/T ratio (A/TPSAU = 0.134
± 0.015) with respect to the values obtained with both the aequorinometer
and the CI-operated SiPM.
Discussion
In
this work, we addressed the challenge of using a SiPM sensor
to detect the luminescence emitted upon Ca2+ release from
living cells expressing aequorin targeted either to the cytosol or
mitochondrial matrix. The main electronic issues connected to the
fulfillment of the essential endowments required to satisfactorily
reconstruct the Ca2+ transients temporal profile, namely,
high dynamic range, extreme sensitivity, and sharp temporal resolution,
were met by devising a parallel-readout scheme allowing the processing
of the SiPM output signal according to SPC and CI acquisition modes
simultaneously. Very recently, Santangelo and co-workers[31] had already undertaken pivotal efforts toward
exploitation of SiPM in luminescence assays. Namely, in ref (31), they tested the linearity
and sensitivity performance of a SiPM-based luminometer with an integrated
microfluidics system in measuring the luminescence originating from
ATP-driven luciferin oxidation. However, although of great interest,
the prototype described in ref (31) was essentially an advanced cuvette-like system. Conversely,
here we demonstrated the ability of working on intact cells in an
aequorinometer-like experimental configuration. On their own, luminescence
traces acquired in the CI mode from AEQ-transfected HeLa cells stimulated
with ATP, and subsequently disrupted by injection of Triton X-100,
exhibited profiles comparable to those from a custom-designed PMT-based
aequorinometer. Conversely, similar traces acquired in the SPC modality
were found to be plagued by severe saturation of the Triton-induced
luminescence burst due to massive pile-up effect, thus making CI acquisition
the option of choice in luminescence experiments. Nevertheless, switching
to the SPC mode proved to be mandatory in order to record even the
weakest signals detected by the SiPM, such as spontaneous cytosolic
calcium oscillations or ATP-stimulated releases from low-density cell
cultures.The SiPM-based system presented herein is not simply
intended as
a valuable and cost-effective alternative to currently exploited technologies
(i.e., PMT-, EMCCD-, ICCD-, and sCMOS-based aequorinometers).[8] Conversely, it claims to represent a strategic
starting point toward the development of a new generation of luminometers
that, by taking advantage of the peculiar features of SiPMs, will
allow performing specific tasks, not necessarily restricted to calcium
and aequorin domains, that are currently unfeasible through conventional
PMTs. Here, it follows a non-exhaustive, albeit suggestive, list of
such possible tasks.SiPM matrices, which are currently commercially
available, may
be exploited for the design of multicolor luminescence detectors through
the integration of proper mosaic filters over the sensor surface.
Such a multicolor setup could be extremely appealing for the biophysicists
and physiologists communities since it could enable the use of multitransfected
cellular models. To this purpose, simultaneous transfection with cyt-AEQ
and mit-AEQ could soon become the new standard for a more informative
wide-spectrum [Ca2+] analysis. Alternatively, mit-AEQ and
luciferase together could represent an unprecedented tool for studying
the energetic balance of the cell, especially in those pathologies
in which mitochondria and ATP metabolisms are known to play a fundamental
role, such as Alzheimer’s disease,[32] Parkinson’s disease,[33] and heart
failure.[34] A multicolor system of this
kind could be also suitable for applications relying on state-of-art
bioluminescent ratiometric probes such as Lotus-V, a BRET-based indicator
for transmembrane voltage measurements.[35]Considering the typical size of a SiPM sensor and the compactness
of both application-specific integrated circuits (ASICs) and dedicated
front-end electronics, a rugged and portable setup for bioluminescence
can also be conceived to be used with those particular samples, or
in those particular environments, that require on-site measurements.
Induced pluripotent stem cells (iPSCs), for instance, are a delicate
cellular model that requires specific competencies and expertise to
be managed and cannot be easily delivered to distant laboratories
for bioluminescence testing. On the other side, Antarctica and space
missions are two realistic examples of extreme environments whose
effects on cell physiology could be efficiently studied by means of
such a compact setup.A further notable field of application
is represented by the market
of microplate readers, currently used as the standard luminometry
technology for parallel drug screening, especially in the academic
context of biomedical research (e.g., Perkin Elmer Victor X/Nivo,
Promega GloMax, and Molecular Devices SpectraMax). All the abovementioned
instruments feature a single bulky PMT in their sensor stage, thus
forcing the screened microplate to mechanically slide over it in a
sequential mode and making parallel time-course recording impossible.
The physical and economic scalability of SiPMs could pave the way
to the implementation of new readers featuring a SiPM matrix with
an independent SiPM sensor under each well of the microplate. This
would allow a parallel and high-throughput real-time acquisition for
each biophysical or biochemical parameter for which a light-emitting
probe is, or will be, available (e.g., membrane voltage, pH, [Ca2+], [ATP], [NAD(+)]/[NADH], and [AA]).As a final note,
with the advancement in SiPM technology, it is
likely to soon witness a progressive improvement of the general features
of these devices, such as shorter pulse durations (leading to higher
performances especially in the SPC mode), smaller microcell pitches,
lower DCR levels, etc. This will foster new applications such as bioluminescence
imaging of single cells or even subcellular compartments.
Conclusions
In this article, we provided a proof of principle for the time-course
recording of intracellular Ca2+ dynamics using an aequorin-based
probe and a SiPM sensor as the bioluminescence detector. In general,
our experiments provide evidence of linearity of the overall system
across three orders of magnitude of aequorin concentration. Charge-integration
and photon-counting modes proved to be two alternative and complementary
modalities for handling the SiPM output signal, coping with strong
and weak bioluminescent signals, respectively.The unquestionable
benefits of solid-state electronics with respect
to PMT technology, together with the rapidly improving SiPM performances,
promise a bright future to bioluminescence measurements according
to the methodology presented herein.
Authors: Jiahui Wu; David L Prole; Yi Shen; Zhihong Lin; Aswini Gnanasekaran; Yingjie Liu; Lidong Chen; Hang Zhou; S R Wayne Chen; Yuriy M Usachev; Colin W Taylor; Robert E Campbell Journal: Biochem J Date: 2014-11-15 Impact factor: 3.857