Literature DB >> 32686488

Repeatability of whole-cornea measurements using a new swept-source optical coherence tomographer.

Pedro Tañá-Rivero1, Salvador Aguilar-Córcoles1, Ramón Ruiz-Mesa2, Robert Montés-Micó1,3.   

Abstract

PURPOSE: The aim of this study was to evaluate the repeatability of several corneal parameters provided by a high-resolution swept-source optical coherence tomographer (SS-OCT).
METHODS: One eye from each of 74 patients was measured five times consequently using the ANTERION SS-OCT. The following corneal parameters were analyzed: average, steep and flat keratometry (K), astigmatism for anterior, posterior and total at 3-mm, average K and astigmatism at 6-mm, anterior and posterior eccentricity, higher-order aberrations (HOA) and spherical aberration (Z40), and anterior and posterior best-fit sphere at 8-mm. The intrasubject standard deviation (Sw), coefficient of variation (CoV), coefficient of repeatability (CoR) and intraclass correlation coefficient (ICC) were calculated for each parameter to assess the repeatability.
RESULTS: We have not found statistically significant differences between repeated measurements (p > 0.05). Repeatability was good considering the different metrics used. Sw values were <0.09, varying from 0.035 (posterior average K at 6-mm) to 0.0878 (anterior flat K at 3-mm). CoV values were also low and similar among the different parameters (from 0.08% to 0.21%), except for anterior, posterior and total astigmatism (from 2.25% to 8.46%). Both anterior and posterior eccentricity, and corneal aberrations (HOA and Z40) CoV values were also high. The CoR values were low for all parameters showing those related to the posterior cornea the lowest values (about 0.01). ICC values were >0.98.
CONCLUSIONS: The ANTERION SS-OCT showed good repeatability when reconstructed different parameters for the whole cornea. This device produces measurements with high repeatability that could be useful for clinical research.

Entities:  

Keywords:  ANTERION; Repeatability; corneal topography; optical coherence tomography; swept source Fourier domain

Mesh:

Year:  2020        PMID: 32686488     DOI: 10.1177/1120672120944022

Source DB:  PubMed          Journal:  Eur J Ophthalmol        ISSN: 1120-6721            Impact factor:   2.597


  6 in total

1.  Comparison of corneal tomography using a novel swept-source optical coherence tomographer and rotating Scheimpflug system in normal and keratoconus eyes: repeatability and agreement analysis.

Authors:  Robert Herber; Janine Lenk; Lutz E Pillunat; Frederik Raiskup
Journal:  Eye Vis (Lond)       Date:  2022-05-23

2.  Comparison of ocular biometric measurements in patients with cataract using three swept-source optical coherence tomography devices.

Authors:  Richul Oh; Joo Youn Oh; Hyuk Jin Choi; Mee Kum Kim; Chang Ho Yoon
Journal:  BMC Ophthalmol       Date:  2021-01-27       Impact factor: 2.209

3.  Lens-vault analysis and its correlation with other biometric parameters using swept-source OCT.

Authors:  Pedro Tañá-Rivero; Ramón Ruiz-Mesa; Salvador Aguilar-Córcoles; Cristina Tello-Elordi; María Ramos-Alzamora; Robert Montés-Micó
Journal:  J Optom       Date:  2021-11-01

4.  Clinical evaluation of ocular biometry of dual Scheimpflug analyzer, GALILEI G6 and swept source optical coherence tomography, ANTERION.

Authors:  Boonsong Wanichwecharungruang; Anyarak Amornpetchsathaporn; Kittipong Kongsomboon; Wisakorn Wongwijitsook; Kornkamol Annopawong; Somporn Chantra
Journal:  Sci Rep       Date:  2022-03-04       Impact factor: 4.379

5.  Evaluation of ocular biometry in primary angle-closure disease with two swept source optical coherence tomography devices.

Authors:  Boonsong Wanichwecharungruang; Anyarak Amornpetchsathaporn; Wisakorn Wongwijitsook; Kittipong Kongsomboon; Somporn Chantra
Journal:  PLoS One       Date:  2022-03-21       Impact factor: 3.240

6.  Anterior segment characteristics in normal and keratoconus eyes evaluated with a new type of swept-source optical coherence tomography.

Authors:  Kook Young Kim; Seongjun Lee; Young Joon Jeon; Ji Sang Min
Journal:  PLoS One       Date:  2022-09-01       Impact factor: 3.752

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.