| Literature DB >> 32584314 |
Kosuke Okuwaki1, Hironori Masutani1, Mitsuhiro Kida1, Hiroshi Yamauchi1, Tomohisa Iwai1, Eiji Miyata1, Rikiya Hasegawa1, Toru Kaneko1, Hiroshi Imaizumi1, Masafumi Watanabe1, Takahiro Kurosu1, Masayoshi Tadehara1, Kai Adachi1, Akihiro Tamaki1, Wasaburo Koizumi1.
Abstract
OBJECTIVES: The aim of this study is to estimate the cutoff length for stereomicroscopically visible white core (SVWC) required for the pathological diagnosis of subepithelial lesions (SELs) from samples obtained using a novel 22-G Franseen biopsy needle and determine the sensitivity using the SVWC cutoff length. PATIENTS AND METHODS: Thirty patients with SELs requiring pathological diagnoses were included. EUS-guided fine-needle biopsies (EUS-FNBs) were performed using a novel 22G Franseen biopsy needle. SVWC cutoff lengths were measured using sample isolation processing by stereomicroscopy (SIPS). The utility of the calculated SVWC cutoff lengths was measured.Entities:
Keywords: EUS; fine-needle biopsy; histopathology; sample isolation processing by stereomicroscopy; subepithelial lesion
Year: 2020 PMID: 32584314 PMCID: PMC7430899 DOI: 10.4103/eus.eus_18_20
Source DB: PubMed Journal: Endosc Ultrasound ISSN: 2226-7190 Impact factor: 5.628
Figure 1The sample isolation processing by stereomicroscopy process for a EUS-fine-needle biopsy sample from a patient with gastrointestinal stromal tumor. (a) The sample in the puncture needle was initially pushed out onto a Petri dish by compressing the air in the syringe and then using a stylet. (b) The vermiform tissue component from the Petri dish was immersed in 10% neutral buffered formalin solution in another previously prepared Petri dish. (c) The stereomicroscopically visible white core lengths (black dashed lines) were measured using a scale on the stereomicroscope monitor screen. (d) The white and red samples were dissected using injection needles and closely aligned on separate filter papers. The photo is a white sample. SIPS: Sample isolation processing by stereomicroscope, EUS-FNB: EUS-guided fine-needle biopsy, GIST: Gastrointestinal stromal tumor, SVWC: Stereomicroscopic visible white core
Characteristics of the patients and lesions
| Number of patients | 30 |
| Median age, years (range) | 67 (23-84) |
| Male/female | 19/11 (63.3/36.7) |
| Number of lesions | 30 |
| Maximum lesion diameters: median, mm (range) | 24 (14-55) |
| Location of lesion | |
| Esophagus | 4 (13.3) |
| Stomach | 24 (80) |
| Duodenum | 2 (6.7) |
Results of EUS-FNB
| Technical success | 30/30 (100) |
| Number of passes per lesion 3 passes | 30 (100) |
| Number of total passes | 90 |
| Adverse events | |
| Bleeding, mild | 2 (6.7) |
EUS-FNB: EUS-guided fine-needle aspiration biopsy
Results of sample isolation processing by stereomicroscopy
| Stereomicroscopic assessments | % ( |
|---|---|
| Presence of SVWC | |
| Per pass | 98.9 (89/90) |
| Per lesion | 100 (30/30) |
| Length of SVWC median, mm (range) | |
| Per pass | 14.5 (1-89)* |
*n=89. SVWC: Stereomicroscopic visible white core
Results of the pathological examination and tissue diagnosis
| % ( | |
|---|---|
| Pathological assessments | |
| Presence of microscopic tissue | |
| Per pass | 97.8 (88/90) |
| Per lesion | 100 (30/30) |
| Diagnosis rates | |
| Per pass malignancy diagnosis | |
| 1st pass | 93.3 (28/30) |
| 2nd pass | 90 (27/30) |
| Cumulative diagnostic rate for up to 2 passes (per lesion) | 96.7 (29/30) |
| 3rd pass | 96.7 (29/30) |
| Cumulative diagnostic rate for up to 3 passes (per lesion) | 100 (30/30) |
| Per lesion malignant diagnosis | |
| Sensitivity | 100 |
| Specificity | 100 |
| PPV | 100 |
| NPV | 100 |
| Accuracy | 100 |
| Per lesion final diagnosis | |
| Accuracy | 100 |
PPV: Positive predictive value; NPV: Negative predictive value.
Final diagnosis
| Location | Final diagnosis | |
|---|---|---|
| Esophagus | GIST | 1* (3.3) |
| Leiomyoma | 2 (6.7) | |
| Schwannoma | 1 (3.3) | |
| Stomach | GIST | 13* (43.3) |
| Leiomyoma | 4 (13.3) | |
| Schwannoma | 6 (20) | |
| Ectopic pancreas | 1 (3.3) | |
| Duodenum | GIST | 2* (6.7) |
*Final diagnosis of malignancy. GIST: Gastrointestinal stromal tumor
Figure 2Receiver operating characteristic curves calculated from the stereomicroscopically visible white core lengths with respect to the diagnostic accuracy. The overall area under the curve is 0.958 (95% confidence interval: 0.897–1.020, P < 0.001). AUC: Area under the curve, CI: Confidence interval, ROC: Receiver operating characteristic, SVWC: Stereomicroscopic visible white core
Results of EUS-FNB using a novel 22-G Franseen biopsy needle according to the cutoff length
| Positive ( | Negative ( | Sensitivity (%) | ||
|---|---|---|---|---|
| Cutoff length: 4 mm | ||||
| Per pass analysis | ||||
| SVWC ≥4 mm | 77 | 1 | 98.7 | <0.001 |
| SVWC <4 mm | 7 | 5 | 58.3 | |
| Per pass analysis | ||||
| SVWC ≥3.5 mm | 77 | 1 | 98.7 | <0.001 |
| SVWC <3.5 mm | 7 | 5 | 58.3 | |
EUS-FNB: EUS-guided fine-needle aspiration biopsy; SVWC: Stereomicroscopic visible white core