| Literature DB >> 32528062 |
Petra Šrámková1, Anna Zahoranová2, Jakub Kelar3, Zlata Kelar Tučeková3, Monika Stupavská3, Richard Krumpolec3, Jana Jurmanová3, Dušan Kováčik3, Mirko Černák3.
Abstract
Poly(2-oxazolines) (Entities:
Year: 2020 PMID: 32528062 PMCID: PMC7289869 DOI: 10.1038/s41598-020-66423-w
Source DB: PubMed Journal: Sci Rep ISSN: 2045-2322 Impact factor: 4.379
Figure 1Schematic representation of experimental procedure and DCSBD plasma source. (a) Experimental procedure for preparation of PMEOx-based coating: (1) plasma activation of PTFE surface, (2) dip-coating of PMEOx layer, (3) drying, (4) plasma post-treatment of PMEOx layer (air and argon used as working gases), (5) washing in distilled water, (6) characterization; (b) Schematic cross-section of DCSBD plasma source with an illustration of sample moving perpendicularly to the axes of the electrodes.
Figure 2Optimization of PTFE plasma pre-treatment in air by WCA and XPS measurements. (a) Ageing behavior of air plasma-treated PTFE measured by WCA during the 28 days of storage. The inserted graph represents the WCA value development in dependence on the plasma exposure time. Mean values ± standard deviation from 12-16 droplets are plotted in the graph; (b) O/C ratio and concentration of O-based functional groups at the PTFE surface in dependence on the plasma exposure time, measured by XPS. Mean values ± standard deviation from 3 spots on the sample are plotted.
Figure 3Optimization of plasma exposure time used for post-treatment of PMEOx coatings. (a) FTIR spectra of PMEOx powder (red dot line), PMEOx layer (black line) and treated PMEOx layer in different air plasma exposure times – 3 s (grey line), 10 s (blue line), 30 s (magenta line), without washing; (b) Relative concentrations of particular chemical bonds from high-resolution C1s spectra of air-plasma treated PMEOx layer as a function of plasma exposure time measured by XPS.
Figure 4Atomic concentration of PMEOx coatings achieved in different plasma treated conditions measured by XPS. Comparison of atomic concentration (%) of C, O, N in PMEOx coating before (sample PMEOx) and after plasma treatment (samples PMEOx-Air, PMEOx-Ar) with PMEOx-REF.
The relative percentage of chemical bonds observed from high-resolution C1s spectra of PMEOx samples before and after washing.
| Sample | Before washing | After washing | ||||||
|---|---|---|---|---|---|---|---|---|
| C1s bonds concentration [%] | C1s bonds concentration [%] | |||||||
| C-C/C-H | C-O/C-N | C=O/N-C=O | COO | C-C/C-H | C-O/C-N | C=O/N-C=O | COO | |
| PMEOx-ref | 38 | 49 | 13 | — | ||||
| PMEOx | 26 | 56 | 18 | — | 13 | 53 | 19 | 15 |
| PMEOx-air | 18 | 57 | 20 | 5 | 13 | 58 | 17 | 12 |
| PMEOx-Ar | 23 | 54 | 23 | — | 30 | 54 | 6 | 10 |
PMEOx reference layer is compared to samples without plasma post-treatment (PMEOx), treated by air-plasma (PMEOx-air) and argon-plasma (PMEOx-Ar). The values of concentrations of chemical bonds after washing are recalculated with exclusion of CFx bonds.
Figure 5WCA and chemical composition development during storage. (a) WCA values of washed PMEOx coatings and their ageing behavior during the 28 days of storage compare to raw PTFE treated by plasma at 3 s; (b) Changes in O/C and F/C ratios of PMEOx coatings during the 7 days of storage.
Figure 6Relative concentrations of particular chemical bonds from high-resolution C1s spectra. Comparison of chemical composition of non-treated (PMEOx) and plasma treated (PMEOx-air, PMEOx-Ar) layer before and after washing to PMEOx-REF.
Figure 7SEM images with inserted yellow values of roughness measured by AFM. Morphology and roughness of raw PTFE is compared to (a) PMEOx layer deposited after PTFE pre-treatment, (b) PMEOx layer deposited on pre-treated PTFE after washing, (c) air-plasma treated PMEOx layer, (d) air-plasma treated PMEOx layer after washing.
Figure 8Study of the adhesion of 3T3 fibroblasts on PTFE and on POx surfaces after 24 h incubation. (a) Density of adherent cells on selected samples (Ref - raw PTFE, PTFE + 30 s - PTFE after 30 s of air plasma treatment, PMEOx – without plasma post-treatment, PMEOx + air – plasma post-treatment in air, PMEOx + Ar – plasma post-treatment in argon) 1 day after preparation. The box represents the median values and interquartile ranges of the number of adherent cells per mm2, the whiskers represent minimal and maximal values. **p < 0.01, ***p < 0.001, ****p < 0.0001, compared to ref (b) Density of adherent cells on selected samples after 30 days of aging. *p < 0.05, ***p < 0.001, ****p < 0.0001, compared to ref or PTFE + 30 s, (c) Representative fluorescent images of adherent cells stained by green FDA. Scale bar = 50 μm.