Literature DB >> 32399896

Predictors for low TAVI-prosthesis position assessed by fusion imaging of pre- and post-procedural CT angiography.

Philipp Breitbart1, Gregor Pache2, Jan Minners3, Manuel Hein3, Holger Schröfel4, Franz-Josef Neumann3, Philipp Ruile3.   

Abstract

BACKGROUND: Low prosthesis position after transcatheter aortic valve implantation (TAVI) is associated with higher rates of new onset conduction disturbances and permanent pacemaker implantations. Purpose of this study was to investigate possible predictors of a low prosthesis position of the SAPIEN 3 (Edwards Lifesciences, Irvine, California, USA) valve type using fusion imaging of pre- and post-procedural computed tomography angiography (CTA).
METHODS: CTA fusion imaging was performed in 120 TAVI-patients with 3D-reconstruction of the transcatheter heart valve (THV) position within the device landing zone. A low implantation position was defined according to the manufacturer's recommendations as > 30% of the prosthesis below the native annulus plane.
RESULTS: A low THV position was found in 17 patients (14%). Patients with low THV position had less calcification of the annulus region and a smaller annulus size compared to patients with a normal or high THV position (P = 0.003 and 0.041, respectively). The only independent predictor of a low THV position in multivariate logistic regression analysis was the extent of calcification of the cusp region (odds ratio [CI] 0.842 [0.727-0.976], P = 0.022).
CONCLUSIONS: Fusion imaging of pre-and post-procedural CTA identified reduced calcification of the cusp region as an independent predictor of a low THV position of the SAPIEN 3. This should be considered when planning the TAVI procedure. Correlation of cusp region calcification and prosthesis position after TAVI.

Entities:  

Keywords:  Computed tomography angiography; Device landing zone calcification; Fusion imaging; Post-TAVI CTA; TAVI; THV positioning

Year:  2020        PMID: 32399896     DOI: 10.1007/s00392-020-01654-5

Source DB:  PubMed          Journal:  Clin Res Cardiol        ISSN: 1861-0684            Impact factor:   5.460


  18 in total

1.  Chronic pacing and adverse outcomes after transcatheter aortic valve implantation.

Authors:  Jose' M Dizon; Tamim M Nazif; Paul L Hess; Angelo Biviano; Hasan Garan; Pamela S Douglas; Samir Kapadia; Vasilis Babaliaros; Howard C Herrmann; Wilson Y Szeto; Hasan Jilaihawi; William F Fearon; E Murat Tuzcu; Augusto D Pichard; Raj Makkar; Mathew Williams; Rebecca T Hahn; Ke Xu; Craig R Smith; Martin B Leon; Susheel K Kodali
Journal:  Heart       Date:  2015-08-10       Impact factor: 5.994

2.  Transcatheter aortic valve implantation in nonagenarians: insights from the German Aortic Valve Registry (GARY).

Authors:  J Blumenstein; H Möllmann; S Bleiziffer; T Bauer; S Ensminger; R Bekeredjian; T Walther; C Frerker; F Beyersdorf; C Hamm; A Beckmann
Journal:  Clin Res Cardiol       Date:  2020-01-28       Impact factor: 5.460

3.  Incidence, predictors, and outcome of conduction disorders after transcatheter self-expandable aortic valve implantation.

Authors:  Chiara Fraccaro; Gianfranco Buja; Giuseppe Tarantini; Valeria Gasparetto; Loira Leoni; Renato Razzolini; Domenico Corrado; Raffaele Bonato; Cristina Basso; Gaetano Thiene; Gino Gerosa; Giambattista Isabella; Sabino Iliceto; Massimo Napodano
Journal:  Am J Cardiol       Date:  2011-01-19       Impact factor: 2.778

Review 4.  Clinical significance of conduction disturbances after aortic valve intervention: current evidence.

Authors:  Manuel Martinez-Selles; Peter Bramlage; Martin Thoenes; Gerhard Schymik
Journal:  Clin Res Cardiol       Date:  2014-07-04       Impact factor: 5.460

5.  Optimized Implantation Height of the Edwards SAPIEN 3 Valve to Minimize Pacemaker Implantation After TAVI.

Authors:  Marius Schwerg; Felix Fulde; Henryk Dreger; Wolfram C Poller; Karl Stangl; Michael Laule
Journal:  J Interv Cardiol       Date:  2016-05-31       Impact factor: 2.279

6.  SOURCE 3 Registry: Design and 30-Day Results of the European Postapproval Registry of the Latest Generation of the SAPIEN 3 Transcatheter Heart Valve.

Authors:  Olaf Wendler; Gerhard Schymik; Hendrik Treede; Helmut Baumgartner; Nicolas Dumonteil; Leo Ihlberg; Franz-Josef Neumann; Giuseppe Tarantini; José Luis Zamarano; Alec Vahanian
Journal:  Circulation       Date:  2017-01-19       Impact factor: 29.690

7.  Fusion imaging of pre- and post-procedural computed tomography angiography in transcatheter aortic valve implantation patients: evaluation of prosthesis position and its influence on new conduction disturbances.

Authors:  Philipp Ruile; Gregor Pache; Jan Minners; Manuel Hein; Franz-Josef Neumann; Philipp Breitbart
Journal:  Eur Heart J Cardiovasc Imaging       Date:  2019-07-01       Impact factor: 6.875

8.  Early clinical and echocardiographic outcomes after SAPIEN 3 transcatheter aortic valve replacement in inoperable, high-risk and intermediate-risk patients with aortic stenosis.

Authors:  Susheel Kodali; Vinod H Thourani; Jonathon White; S Chris Malaisrie; Scott Lim; Kevin L Greason; Mathew Williams; Mayra Guerrero; Andrew C Eisenhauer; Samir Kapadia; Dean J Kereiakes; Howard C Herrmann; Vasilis Babaliaros; Wilson Y Szeto; Rebecca T Hahn; Philippe Pibarot; Neil J Weissman; Jonathon Leipsic; Philipp Blanke; Brian K Whisenant; Rakesh M Suri; Raj R Makkar; Girma M Ayele; Lars G Svensson; John G Webb; Michael J Mack; Craig R Smith; Martin B Leon
Journal:  Eur Heart J       Date:  2016-03-31       Impact factor: 29.983

9.  Predictors of Permanent Pacemaker Implantations and New-Onset Conduction Abnormalities With the SAPIEN 3 Balloon-Expandable Transcatheter Heart Valve.

Authors:  Oliver Husser; Costanza Pellegrini; Thorsten Kessler; Christof Burgdorf; Hannah Thaller; N Patrick Mayr; Albert M Kasel; Adnan Kastrati; Heribert Schunkert; Christian Hengstenberg
Journal:  JACC Cardiovasc Interv       Date:  2016-02-08       Impact factor: 11.195

10.  Repositionable Versus Balloon-Expandable Devices for Transcatheter Aortic Valve Implantation in Patients With Aortic Stenosis.

Authors:  Thomas Pilgrim; Stefan Stortecky; Fabian Nietlispach; Dik Heg; David Tueller; Stefan Toggweiler; Enrico Ferrari; Stéphane Noble; Francesco Maisano; Raban Jeger; Marco Roffi; Jürg Grünenfelder; Christoph Huber; Peter Wenaweser; Stephan Windecker
Journal:  J Am Heart Assoc       Date:  2016-11-17       Impact factor: 5.501

View more
  6 in total

1.  Global longitudinal strain by feature tracking for optimized prediction of adverse remodeling after ST-elevation myocardial infarction.

Authors:  Martin Reindl; Christina Tiller; Magdalena Holzknecht; Ivan Lechner; Dorothea Eisner; Laura Riepl; Mathias Pamminger; Benjamin Henninger; Agnes Mayr; Johannes P Schwaiger; Gert Klug; Axel Bauer; Bernhard Metzler; Sebastian J Reinstadler
Journal:  Clin Res Cardiol       Date:  2020-04-15       Impact factor: 5.460

2.  Hypothermia in patients with acute myocardial infarction: a meta-analysis of randomized trials.

Authors:  Brunilda Alushi; Gjin Ndrepepa; Alexander Lauten; Anna Lena Lahmann; Dario Bongiovanni; Sebastian Kufner; Erion Xhepa; Karl-Ludwig Laugwitz; Michael Joner; Ulf Landmesser; Holger Thiele; Adnan Kastrati; Salvatore Cassese
Journal:  Clin Res Cardiol       Date:  2020-04-17       Impact factor: 5.460

3.  Noncalcified plaque burden quantified from coronary computed tomography angiography improves prediction of side branch occlusion after main vessel stenting in bifurcation lesions: results from the CT-PRECISION registry.

Authors:  Kajetan Grodecki; Sebastien Cadet; Adam D Staruch; Anna M Michalowska; Cezary Kepka; Rafal Wolny; Jerzy Pregowski; Mariusz Kruk; Mariusz Debski; Artur Debski; Ilona Michalowska; Piotr J Slomka; Adam Witkowski; Damini Dey; Maksymilian P Opolski
Journal:  Clin Res Cardiol       Date:  2020-05-08       Impact factor: 5.460

4.  Impact of the Aortic Geometry on TAVI Prosthesis Positioning Using Self-Expanding Valves.

Authors:  Philipp Breitbart; Martin Czerny; Jan Minners; Holger Schröfel; Franz-Josef Neumann; Philipp Ruile
Journal:  J Clin Med       Date:  2022-04-18       Impact factor: 4.964

5.  Long-term safety of paclitaxel drug-coated balloon-only angioplasty for de novo coronary artery disease: the SPARTAN DCB study.

Authors:  Vassilios S Vassiliou; Simon C Eccleshall; Ioannis Merinopoulos; Tharusha Gunawardena; Upul Wickramarachchi; Paul Richardson; Clint Maart; Sulfi Sreekumar; Chris Sawh; Trevor Wistow; Toomas Sarev; Alisdair Ryding; Tim Gilbert; Aris Perperoglou
Journal:  Clin Res Cardiol       Date:  2020-09-02       Impact factor: 5.460

6.  Implantation depth and its influence on complications after TAVI with self-expanding valves.

Authors:  Philipp Breitbart; Jan Minners; Manuel Hein; Holger Schröfel; Franz-Josef Neumann; Philipp Ruile
Journal:  Int J Cardiovasc Imaging       Date:  2021-05-14       Impact factor: 2.357

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.