| Literature DB >> 32306923 |
Yu Zhao1,2,3, Feng Zhao1,2,3,4, Tian Han1,2,3, Jing Zhao1,2,3, Xingtao Zhou5,6,7.
Abstract
BACKGROUND: To evaluate lenticule surface characteristics of small incision lenticule extraction (SMILE) for hyperopia correction in rabbits.Entities:
Keywords: Hyperopia correction; Lenticule quality; Refractive surgery; Small incicion lenticule extraction
Mesh:
Year: 2020 PMID: 32306923 PMCID: PMC7169024 DOI: 10.1186/s12886-020-01432-x
Source DB: PubMed Journal: BMC Ophthalmol ISSN: 1471-2415 Impact factor: 2.209
Criteria for evaluating surface characteristics
| Criterion and Magnification | Appearance | Scores | |
|---|---|---|---|
| A | Surface relief ×100 | Very smooth | 4 |
| Smooth | 3 | ||
| Rough | 2 | ||
| Very rough | 1 | ||
| B | Regularity of surface structure ×300 | Completely regular | 4 |
| Almost Regular | 3 | ||
| Partially regular | 2 | ||
| Not regular | 1 | ||
| C | Portion of surface irregular ×300 | < 10% of cut surface | 4 |
| 11–25% of cut surface | 3 | ||
| 26–50% of cut surface | 2 | ||
| > 50% of cut surface | 1 | ||
| D | Position of the irregular area ×300 | No irregularities | 4 |
| Peripheral only | 3 | ||
| Large region | 2 | ||
| All over | 1 |
Score results for lenticules in two groups
| Surface | Group | Sample | Surface Relief | Regularity of Surface | Portion of Surface Irregular | Position of the Irregular | Score | Average | SD |
|---|---|---|---|---|---|---|---|---|---|
| Anterior | Hyperopia | 1 L | 3 | 3 | 4 | 3 | 13 | 11.75 | 2.50 |
| 3 L | 2 | 2 | 2 | 2 | 8 | ||||
| 5 L | 3 | 3 | 4 | 3 | 13 | ||||
| 7 L | 3 | 3 | 4 | 3 | 13 | ||||
| Myopia | 1R | 3 | 3 | 4 | 3 | 13 | 12.75 | 0.50 | |
| 3R | 3 | 3 | 4 | 3 | 13 | ||||
| 5R | 3 | 3 | 3 | 3 | 12 | ||||
| 7R | 3 | 3 | 4 | 3 | 13 | ||||
| Posterior | Hyperopia | 2 L | 2 | 2 | 3 | 3 | 10 | 12.25 | 1.50 |
| 4 L | 3 | 3 | 4 | 3 | 13 | ||||
| 6 L | 3 | 3 | 4 | 3 | 13 | ||||
| 8 L | 3 | 3 | 4 | 3 | 13 | ||||
| Myopia | 2R | 2 | 2 | 2 | 2 | 8 | 11.33 | 2.89 | |
| 6R | 3 | 3 | 4 | 3 | 13 | ||||
| 8R | 3 | 3 | 4 | 3 | 13 |
SD standard deviation
1 L means lenticule from the left eye of the rabbit numbered 1 and so on
Fig. 1Images of anterior surface of hyperopia lenticule from the left eye of the rabbit numbered 3 at 100× magnification (a) and at 300 × magnification (b). With example of the score result of 8 points
Fig. 2Images of anterior surface of hyperopia lenticule from the left eye of the rabbit numbered 7 at 100× magnification (a) and at 300 × magnification (b). With example of the score result of 13 points
Fig. 3Images of posterior surface of hyperopia lenticule from the left eye of the rabbit numbered 2 at 100× magnification (a) and at 300 × magnification (b). With example of the score result of 10 points
Fig. 4Images of posterior surface of myopia lenticule from the right eye of the rabbit numbered 2 at 100× magnification (a) and at 300 × magnification (b). With example of the score result of 8 points