Surface quality of femtosecond dissected posterior human corneal stroma investigated with atomic force microscopy.

Marco Lombardo1, Maria P De Santo, Giuseppe Lombardo, Domenico Schiano Lomoriello, Giovanni Desiderio, Pietro Ducoli, Riccardo Barberi, Sebastiano Serrao.   

Abstract

PURPOSE: To investigate and compare the surface roughness and morphology of posterior stromal lenticules created with a femtosecond laser using various pulse energies to that obtained with a mechanical microkeratome.
METHODS: A 150 kHz femtosecond laser platform (IntraLase iFS; Abbott Medical Optics) was programmed to create an 8.5-mm-diameter posterior stromal lenticule in 12 human corneal tissues. Specimens were dissected using different pulse energies (1.00, 0.75, 0.65, and 0.50) and fixed 2 μm spot separations. Three additional posterior corneal lenticules were prepared using a mechanical microkeratome (Moria Evolution 3; Moria). After the procedure, each corneal tissue was examined by atomic force microscopy (Autoprobe CP; Veeco).
RESULTS: Femtosecond laser-treated tissues revealed similar morphological features, however, with significant differences in surface roughness in relation to the energy pulse used for lamellar dissection (P<0.001). The most regular stromal surface was achieved when using 0.50 μJ pulse energy; on the contrary, the roughest specimens were those dissected using 1.00 μJ pulse energy. No differences in surface roughness were measured between mechanically resected tissues and those treated using 0.50 μJ pulse energy (P>0.05).
CONCLUSIONS: Atomic force microscopy submicron analysis of femtosecond-dissected donor tissues provided quantitative demonstration of the relation between pulse energy and stromal surface roughness. Surface quality of posterior corneal lenticules, comparable with that provided by mechanical microkeratome, is significantly improved when setting pulse energy for lamellar dissection of 0.50-μJ and 2-μm spot separations.

Entities:  

Mesh:

Year:  2012        PMID: 22262224     DOI: 10.1097/ICO.0b013e31823f774c

Source DB:  PubMed          Journal:  Cornea        ISSN: 0277-3740            Impact factor:   2.651


  12 in total

1.  Comparison of anterior segment measurements using rotating Scheimpflug imaging and partial coherence interferometry.

Authors:  Mohammad Soleimani; Hassan Hashemi; Shiva Mehravaran; Mehdi Khabazkhoob; Mohammad Hassan Emamian; Mohammad Shariati; Akbar Fotouhi
Journal:  Int J Ophthalmol       Date:  2013-08-18       Impact factor: 1.779

2.  A microscopic study of the corneal stromal lenticules extracted during femtosecond laser-assisted small incision lenticule extraction.

Authors:  Yewei Yin; Tu Hu; Aiqun Xiang; Yanyan Fu; Yang Zhao; Xiaoying Wu; Xiaoying Wu; Dan Wen
Journal:  Exp Ther Med       Date:  2021-04-25       Impact factor: 2.447

3.  Interface quality of different corneal lamellar-cut depths for femtosecond laser-assisted lamellar anterior keratoplasty.

Authors:  Chenxing Zhang; Matthew Bald; Maolong Tang; Yan Li; David Huang
Journal:  J Cataract Refract Surg       Date:  2015-03-04       Impact factor: 3.351

4.  Comparison of four methods of surface roughness assessment of corneal stromal bed after lamellar cutting.

Authors:  Clotilde Jumelle; Alina Hamri; Gregory Egaud; Cyril Mauclair; Stephanie Reynaud; Virginie Dumas; Sandrine Pereira; Thibaud Garcin; Philippe Gain; Gilles Thuret
Journal:  Biomed Opt Express       Date:  2017-10-12       Impact factor: 3.732

5.  Quality of corneal lamellar cuts quantified using atomic force microscopy.

Authors:  Noël M Ziebarth; Janice Dias; Volkan Hürmeriç; Mohamed Abou Shousha; Chiyat Ben Yau; Vincent T Moy; William W Culbertson; Sonia H Yoo
Journal:  J Cataract Refract Surg       Date:  2012-11-07       Impact factor: 3.351

6.  Laboratory Evaluation of Femtosecond Laser Lamellar Cuts in Gamma-Irradiated Corneas.

Authors:  Chenxing Zhang; Liang Liu; Maolong Tang; Yan Li; Winston Chamberlain; David Huang
Journal:  Cornea       Date:  2015-11       Impact factor: 2.651

Review 7.  Eye-bank preparation of endothelial tissue.

Authors:  Grace E Boynton; Maria A Woodward
Journal:  Curr Opin Ophthalmol       Date:  2014-07       Impact factor: 3.761

8.  Comparative study of corneal endothelial cell damage after femtosecond laser assisted deep stromal dissection.

Authors:  Ting Liu; Jingjing Zhang; Dapeng Sun; Wenjie Sui; Yangyang Zhang; Dongfang Li; Zhaoli Chen; Hua Gao
Journal:  Biomed Res Int       Date:  2014-07-10       Impact factor: 3.411

9.  Analysis of femtosecond laser assisted capsulotomy cutting edges and manual capsulorhexis using environmental scanning electron microscopy.

Authors:  Sebastiano Serrao; Giuseppe Lombardo; Giovanni Desiderio; Lucio Buratto; Domenico Schiano-Lomoriello; Marco Pileri; Marco Lombardo
Journal:  J Ophthalmol       Date:  2014-11-20       Impact factor: 1.909

10.  Preliminary Investigation of the Mechanical Anisotropy of the Normal Human Corneal Stroma.

Authors:  Chao Xue; Yaoqi Xiang; Min Shen; Di Wu; Yan Wang
Journal:  J Ophthalmol       Date:  2018-10-17       Impact factor: 1.909

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.