Literature DB >> 32305565

A field-monitoring-based approach for correcting eddy-current-induced artifacts of up to the 2nd spatial order in human-connectome-project-style multiband diffusion MRI experiment at 7T: A pilot study.

Ruoyun Ma1, Mehmet Akçakaya2, Steen Moeller1, Edward Auerbach1, Kâmil Uğurbil1, Pierre-François Van de Moortele3.   

Abstract

Over the recent years, significant advances in Spin-Echo (SE) Echo-Planar (EP) Diffusion MRI (dMRI) have enabled improved fiber tracking conspicuity in the human brain. At the same time, pushing the spatial resolution and using higher b-values inherently expose the acquired images to further eddy-current-induced distortion and blurring. Recently developed data-driven correction techniques, capable of significantly mitigating these defects, are included in the reconstruction pipelines developed for the Human Connectome Project (HCP) driven by the NIH BRAIN initiative. In this case, however, corrections are derived from the original diffusion-weighted (DW) magnitude images affected by distortion and blurring. Considering the complexity of k-space deviations in the presence of time varying high spatial order eddy currents, distortion and blurring may not be fully reversed when relying on magnitude DW images only. An alternative approach, consisting of iteratively reconstructing DW images based on the actual magnetic field spatiotemporal evolution measured with a magnetic field monitoring camera, has been successfully implemented at 3T in single band dMRI (Wilm et al., 2017, 2015). In this study, we aim to demonstrate the efficacy of this eddy current correction method in the challenging context of HCP-style multiband (MB ​= ​2) dMRI protocol. The magnetic field evolution was measured during the EP-dMRI readout echo train with a field monitoring camera equipped with 16 19F NMR probes. The time variation of 0th, 1st and 2nd order spherical field harmonics were used to reconstruct DW images. Individual DW images reconstructed with and without field correction were compared. The impact of eddy current correction was evaluated by comparing the corresponding direction-averaged DW images and fractional anisotropy (FA) maps. 19F field monitoring data confirmed the existence of significant field deviations induced by the diffusion-encoding gradients, with variations depending on diffusion gradient amplitude and direction. In DW images reconstructed with the field correction, residual aliasing artifacts were reduced or eliminated, and when high b-values were applied, better gray/white matter delineation and sharper gyri contours were observed, indicating reduced signal blurring. The improvement in image quality further contributed to sharper contours and better gray/white matter delineation in mean DW images and FA maps. In conclusion, we demonstrate that up-to-2nd-order-eddy-current-induced field perturbation in multiband, in-plane accelerated HCP-style dMRI acquisition at 7T can be corrected by integrating the measured field evolution in image reconstruction.
Copyright © 2020. Published by Elsevier Inc.

Entities:  

Keywords:  Diffusion MRI; Eddy current correction; Field correction; Field monitoring; Human connectome project

Mesh:

Year:  2020        PMID: 32305565      PMCID: PMC7784530          DOI: 10.1016/j.neuroimage.2020.116861

Source DB:  PubMed          Journal:  Neuroimage        ISSN: 1053-8119            Impact factor:   6.556


  38 in total

1.  Advances in sensitivity encoding with arbitrary k-space trajectories.

Authors:  K P Pruessmann; M Weiger; P Börnert; P Boesiger
Journal:  Magn Reson Med       Date:  2001-10       Impact factor: 4.668

2.  Rapid gridding reconstruction with a minimal oversampling ratio.

Authors:  Philip J Beatty; Dwight G Nishimura; John M Pauly
Journal:  IEEE Trans Med Imaging       Date:  2005-06       Impact factor: 10.048

3.  Diffusion MRI with concurrent magnetic field monitoring.

Authors:  Bertram J Wilm; Zoltan Nagy; Christoph Barmet; S Johanna Vannesjo; Lars Kasper; Max Haeberlin; Simon Gross; Benjamin E Dietrich; David O Brunner; Thomas Schmid; Klaas P Pruessmann
Journal:  Magn Reson Med       Date:  2015-07-17       Impact factor: 4.668

4.  Human Connectome Project-style resting-state functional MRI at 7 Tesla using radiofrequency parallel transmission.

Authors:  Xiaoping Wu; Edward J Auerbach; An T Vu; Steen Moeller; Pierre-François Van de Moortele; Essa Yacoub; Kâmil Uğurbil
Journal:  Neuroimage       Date:  2018-09-17       Impact factor: 6.556

5.  Evaluation of principal component analysis image denoising on multi-exponential MRI relaxometry.

Authors:  Mark D Does; Jonas Lynge Olesen; Kevin D Harkins; Teresa Serradas-Duarte; Daniel F Gochberg; Sune N Jespersen; Noam Shemesh
Journal:  Magn Reson Med       Date:  2019-02-05       Impact factor: 4.668

6.  Denoising of diffusion MRI using random matrix theory.

Authors:  Jelle Veraart; Dmitry S Novikov; Daan Christiaens; Benjamin Ades-Aron; Jan Sijbers; Els Fieremans
Journal:  Neuroimage       Date:  2016-08-11       Impact factor: 6.556

7.  The Lifespan Human Connectome Project in Aging: An overview.

Authors:  Susan Y Bookheimer; David H Salat; Melissa Terpstra; Beau M Ances; Deanna M Barch; Randy L Buckner; Gregory C Burgess; Sandra W Curtiss; Mirella Diaz-Santos; Jennifer Stine Elam; Bruce Fischl; Douglas N Greve; Hannah A Hagy; Michael P Harms; Olivia M Hatch; Trey Hedden; Cynthia Hodge; Kevin C Japardi; Taylor P Kuhn; Timothy K Ly; Stephen M Smith; Leah H Somerville; Kâmil Uğurbil; Andre van der Kouwe; David Van Essen; Roger P Woods; Essa Yacoub
Journal:  Neuroimage       Date:  2018-10-15       Impact factor: 6.556

8.  ESPIRiT--an eigenvalue approach to autocalibrating parallel MRI: where SENSE meets GRAPPA.

Authors:  Martin Uecker; Peng Lai; Mark J Murphy; Patrick Virtue; Michael Elad; John M Pauly; Shreyas S Vasanawala; Michael Lustig
Journal:  Magn Reson Med       Date:  2014-03       Impact factor: 4.668

9.  Extending the Human Connectome Project across ages: Imaging protocols for the Lifespan Development and Aging projects.

Authors:  Michael P Harms; Leah H Somerville; Beau M Ances; Jesper Andersson; Deanna M Barch; Matteo Bastiani; Susan Y Bookheimer; Timothy B Brown; Randy L Buckner; Gregory C Burgess; Timothy S Coalson; Michael A Chappell; Mirella Dapretto; Gwenaëlle Douaud; Bruce Fischl; Matthew F Glasser; Douglas N Greve; Cynthia Hodge; Keith W Jamison; Saad Jbabdi; Sridhar Kandala; Xiufeng Li; Ross W Mair; Silvia Mangia; Daniel Marcus; Daniele Mascali; Steen Moeller; Thomas E Nichols; Emma C Robinson; David H Salat; Stephen M Smith; Stamatios N Sotiropoulos; Melissa Terpstra; Kathleen M Thomas; M Dylan Tisdall; Kamil Ugurbil; Andre van der Kouwe; Roger P Woods; Lilla Zöllei; David C Van Essen; Essa Yacoub
Journal:  Neuroimage       Date:  2018-09-24       Impact factor: 6.556

10.  Resting-state fMRI in the Human Connectome Project.

Authors:  Stephen M Smith; Christian F Beckmann; Jesper Andersson; Edward J Auerbach; Janine Bijsterbosch; Gwenaëlle Douaud; Eugene Duff; David A Feinberg; Ludovica Griffanti; Michael P Harms; Michael Kelly; Timothy Laumann; Karla L Miller; Steen Moeller; Steve Petersen; Jonathan Power; Gholamreza Salimi-Khorshidi; Abraham Z Snyder; An T Vu; Mark W Woolrich; Junqian Xu; Essa Yacoub; Kamil Uğurbil; David C Van Essen; Matthew F Glasser
Journal:  Neuroimage       Date:  2013-05-20       Impact factor: 6.556

View more
  1 in total

Review 1.  What's new and what's next in diffusion MRI preprocessing.

Authors:  Chantal M W Tax; Matteo Bastiani; Jelle Veraart; Eleftherios Garyfallidis; M Okan Irfanoglu
Journal:  Neuroimage       Date:  2021-12-26       Impact factor: 7.400

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.