Rapid gridding reconstruction with a minimal oversampling ratio.

Philip J Beatty1, Dwight G Nishimura, John M Pauly.   

Abstract

Reconstruction of magnetic resonance images from data not falling on a Cartesian grid is a Fourier inversion problem typically solved using convolution interpolation, also known as gridding. Gridding is simple and robust and has parameters, the grid oversampling ratio and the kernel width, that can be used to trade accuracy for computational memory and time reductions. We have found that significant reductions in computation memory and time can be obtained while maintaining high accuracy by using a minimal oversampling ratio, from 1.125 to 1.375, instead of the typically employed grid oversampling ratio of two. When using a minimal oversampling ratio, appropriate design of the convolution kernel is important for maintaining high accuracy. We derive a simple equation for choosing the optimal Kaiser-Bessel convolution kernel for a given oversampling ratio and kernel width. As well, we evaluate the effect of presampling the kernel, a common technique used to reduce the computation time, and find that using linear interpolation between samples adds negligible error with far less samples than is necessary with nearest-neighbor interpolation. We also develop a new method for choosing the optimal presampled kernel. Using a minimal oversampling ratio and presampled kernel, we are able to perform a three-dimensional (3-D) reconstruction in one-eighth the time and requiring one-third the computer memory versus using an oversampling ratio of two and a Kaiser-Bessel convolution kernel, while maintaining the same level of accuracy.

Mesh:

Year:  2005        PMID: 15959939     DOI: 10.1109/TMI.2005.848376

Source DB:  PubMed          Journal:  IEEE Trans Med Imaging        ISSN: 0278-0062            Impact factor:   10.048


  92 in total

1.  MODEL-BASED IMAGE RECONSTRUCTION FOR MRI.

Authors:  Jeffrey A Fessler
Journal:  IEEE Signal Process Mag       Date:  2010-07-01       Impact factor: 12.551

2.  NonCartesian MR image reconstruction with integrated gradient nonlinearity correction.

Authors:  Shengzhen Tao; Joshua D Trzasko; Yunhong Shu; John Huston; Kevin M Johnson; Paul T Weavers; Erin M Gray; Matt A Bernstein
Journal:  Med Phys       Date:  2015-12       Impact factor: 4.071

3.  B0 concomitant field compensation for MRI systems employing asymmetric transverse gradient coils.

Authors:  Paul T Weavers; Shengzhen Tao; Joshua D Trzasko; Louis M Frigo; Yunhong Shu; Matthew A Frick; Seung-Kyun Lee; Thomas K-F Foo; Matt A Bernstein
Journal:  Magn Reson Med       Date:  2017-06-21       Impact factor: 4.668

4.  Noncontrast-enhanced three-dimensional (3D) intracranial MR angiography using pseudocontinuous arterial spin labeling and accelerated 3D radial acquisition.

Authors:  Huimin Wu; Walter F Block; Patrick A Turski; Charles A Mistretta; Kevin M Johnson
Journal:  Magn Reson Med       Date:  2012-04-24       Impact factor: 4.668

5.  Least-square NUFFT methods applied to 2-D and 3-D radially encoded MR image reconstruction.

Authors:  Jiayu Song; Yanhui Liu; Sally L Gewalt; Gary Cofer; G Allan Johnson; Qing Huo Liu
Journal:  IEEE Trans Biomed Eng       Date:  2009-01-23       Impact factor: 4.538

6.  Ramped hybrid encoding for improved ultrashort echo time imaging.

Authors:  Hyungseok Jang; Curtis N Wiens; Alan B McMillan
Journal:  Magn Reson Med       Date:  2015-09-18       Impact factor: 4.668

7.  A comparison of radial keyhole strategies for high spatial and temporal resolution 4D contrast-enhanced MRI in small animal tumor models.

Authors:  Ergys Subashi; Everett J Moding; Gary P Cofer; James R MacFall; David G Kirsch; Yi Qi; G Allan Johnson
Journal:  Med Phys       Date:  2013-02       Impact factor: 4.071

8.  A rapid and robust gradient measurement technique using dynamic single-point imaging.

Authors:  Hyungseok Jang; Alan B McMillan
Journal:  Magn Reson Med       Date:  2016-10-03       Impact factor: 4.668

9.  Anisotropic field-of-view shapes for improved PROPELLER imaging.

Authors:  Peder E Z Larson; Michael S Lustig; Dwight G Nishimura
Journal:  Magn Reson Imaging       Date:  2008-09-24       Impact factor: 2.546

10.  Accelerated 4D quantitative single point EPR imaging using model-based reconstruction.

Authors:  Hyungseok Jang; Shingo Matsumoto; Nallathamby Devasahayam; Sankaran Subramanian; Jiachen Zhuo; Murali C Krishna; Alan B McMillan
Journal:  Magn Reson Med       Date:  2014-05-06       Impact factor: 4.668