Junhan Pan1, Luyou Yan1, Hui Gao1, Yewen He1, Zeya Zhong1, Ping Li1, Yaxi Zhang2, Ying Guo2, Liangying Liao1, Shuwei Zhou1, Kun Zhang1,3. 1. Department of Radiology, First Affiliated Hospital of Hunan University of Chinese Medicine, Changsha 410007, China. 2. GE Healthcare (Shanghai) Co., Ltd., Shanghai 201203, China. 3. College of Integrated Traditional Chinese and Western Medicine, Hunan University of Chinese Medicine, Changsha 410208, China.
Abstract
BACKGROUND: Hydroxyapatite (HAP) is the main component of bone mineral. The utility of using HAP-water decomposition technique with fast kilovoltage (KV)-switching dual-energy computed tomography (DECT) to detect abnormal edema in vertebral compression fractures (VCFs) has not been widely reported. METHODS: A total of 31 consecutive patients with 80 VCFs who underwent DECT and magnetic resonance imaging (MRI) of the spine were retrospectively enrolled in our study between October 2018 and January 2019. VCFs in MR examinations served as the standard of reference. Two radiologists blindly and independently evaluated color-coded overlay virtual nonhydroxyapatite (VNHAP) images for the presence of abnormal edema. The inter-reader agreement, specificity, sensitivity, accuracy, and predictive values of VNHAP images for edema detection were calculated. The diagnostic accuracy of two readers was compared using McNemar's test. Two additional radiologists performed a quantitative analysis on VNHAP images, receiver operating characteristic (ROC) curve analysis was conducted, and the threshold was calculated. RESULTS: MRI depicted 45 edematous and 35 nonedematous VCFs. For visual analysis, the VNHAP technique showed a sensitivity of 93.3%, a specificity of 97.1%, a positive predictive value (PPV) of 97.7%, a negative predictive value (NPV) of 91.9%, and an accuracy of 95.0%. The inter-reader agreement was almost perfect (k=0.90). The diagnostic accuracy of the two readers showed no significant differences in the assessment of VNHAP images (P=1.00). Significant differences in CT numbers between vertebrae with and without bone marrow edema were found by quantitative analysis (P<0.01). The area under the curve (AUC) of the VNHAP images was estimated to be 0.917. The threshold of 1,003.2 mg/cm3 yielded a sensitivity of 88.9% and a specificity of 82.9% for the differentiation of fresh and old VCFs. CONCLUSIONS: Fast KV-switching DECT HAP-water decomposition technique had excellent diagnostic performance for identifying acute and chronic VCFs in visual and quantitative analyses. 2020 Quantitative Imaging in Medicine and Surgery. All rights reserved.
BACKGROUND: Hydroxyapatite (HAP) is the main component of bone mineral. The utility of using HAP-water decomposition technique with fast kilovoltage (KV)-switching dual-energy computed tomography (DECT) to detect abnormal edema in vertebral compression fractures (VCFs) has not been widely reported. METHODS: A total of 31 consecutive patients with 80 VCFs who underwent DECT and magnetic resonance imaging (MRI) of the spine were retrospectively enrolled in our study between October 2018 and January 2019. VCFs in MR examinations served as the standard of reference. Two radiologists blindly and independently evaluated color-coded overlay virtual nonhydroxyapatite (VNHAP) images for the presence of abnormal edema. The inter-reader agreement, specificity, sensitivity, accuracy, and predictive values of VNHAP images for edema detection were calculated. The diagnostic accuracy of two readers was compared using McNemar's test. Two additional radiologists performed a quantitative analysis on VNHAP images, receiver operating characteristic (ROC) curve analysis was conducted, and the threshold was calculated. RESULTS: MRI depicted 45 edematous and 35 nonedematous VCFs. For visual analysis, the VNHAP technique showed a sensitivity of 93.3%, a specificity of 97.1%, a positive predictive value (PPV) of 97.7%, a negative predictive value (NPV) of 91.9%, and an accuracy of 95.0%. The inter-reader agreement was almost perfect (k=0.90). The diagnostic accuracy of the two readers showed no significant differences in the assessment of VNHAP images (P=1.00). Significant differences in CT numbers between vertebrae with and without bone marrow edema were found by quantitative analysis (P<0.01). The area under the curve (AUC) of the VNHAP images was estimated to be 0.917. The threshold of 1,003.2 mg/cm3 yielded a sensitivity of 88.9% and a specificity of 82.9% for the differentiation of fresh and old VCFs. CONCLUSIONS: Fast KV-switching DECT HAP-water decomposition technique had excellent diagnostic performance for identifying acute and chronic VCFs in visual and quantitative analyses. 2020 Quantitative Imaging in Medicine and Surgery. All rights reserved.
Entities:
Keywords:
Dual-energy computed tomography (DECT); bone marrow edema; compression fracture; material decomposition; spine
Authors: Bernhard Petritsch; Aleksander Kosmala; Andreas M Weng; Bernhard Krauss; Anke Heidemeier; Richard Wagner; Timo M Heintel; Tobias Gassenmaier; Thorsten A Bley Journal: Radiology Date: 2017-02-27 Impact factor: 11.105
Authors: Caroline A H Klazen; Paul N M Lohle; Jolanda de Vries; Frits H Jansen; Alexander V Tielbeek; Marion C Blonk; Alexander Venmans; Willem Jan J van Rooij; Marinus C Schoemaker; Job R Juttmann; Tjoen H Lo; Harald J J Verhaar; Yolanda van der Graaf; Kaspar J van Everdingen; Alex F Muller; Otto E H Elgersma; Dirk R Halkema; Hendrik Fransen; Xavier Janssens; Erik Buskens; Willem P Th M Mali Journal: Lancet Date: 2010-08-09 Impact factor: 79.321
Authors: Aleksander Kosmala; Andreas Max Weng; Anke Heidemeier; Bernhard Krauss; Stefan Knop; Thorsten Alexander Bley; Bernhard Petritsch Journal: Radiology Date: 2017-08-11 Impact factor: 11.105
Authors: R Lindsay; S L Silverman; C Cooper; D A Hanley; I Barton; S B Broy; A Licata; L Benhamou; P Geusens; K Flowers; H Stracke; E Seeman Journal: JAMA Date: 2001-01-17 Impact factor: 56.272
Authors: George A Carberry; B Dustin Pooler; Neil Binkley; Travis B Lauder; Richard J Bruce; Perry J Pickhardt Journal: Radiology Date: 2013-02-28 Impact factor: 11.105