Literature DB >> 32189939

Patient satisfaction related outcome after total hip arthroplasty; does bearing surface play a role?

Shubhranshu S Mohanty1, Hariharan Mohan1, Tushar N Rathod1, Prashant Kamble1.   

Abstract

BACKGROUND: The aim of this study was to compare the functional outcome, the patient's perception of the replaced hip joint with different bearing surfaces and to study the effect of femoral head size on joint perception as well.
METHODS: One hundred and ten (110) patients, who underwent primary total hip replacement with an average follow-up of 48 months (12-156 months), were assessed for their functional outcome and joint perception. The functional outcome was calculated based on Oxford hip score (OHS) and SF-36. Joint perception was categorized as to whether the replaced joint was perceived like a natural joint or artificial joint with or without restriction of movements.
RESULTS: There were 50 patients operated for ceramic on ceramic (CoC-hard-on-hard bearing), 60 patients for hard-on-soft bearing (Metal on Polyethelene-MoP 46, Ceramic on Polyethelene-CoP 14). Most of the patients with hard-on-hard bearings perceived their operated hip like a natural joint (p = 0.04) compared to hard-on-soft bearings. There was no significant difference in the functional outcome (OHS, SF-36) between the two bearing surface groups (p > 0.05). There were fifty patients with 28 mm size head while remaining 60 had larger heads (>32 mm). Patients with large heads felt like natural joint compared to small heads (p = 0.007).
CONCLUSION: The hard-on-hard bearing surfaces (CoC) and large femoral heads (32 mm, 36 mm) are perceived more like a natural joint. Different bearing surfaces do not affect the functional outcome after total hip replacement in a medium term follow up.
© 2019.

Entities:  

Keywords:  Bearing surface; Functional outcome; Patient satisfaction; Total hip arthroplasty

Year:  2020        PMID: 32189939      PMCID: PMC7068008          DOI: 10.1016/j.jcot.2019.12.017

Source DB:  PubMed          Journal:  J Clin Orthop Trauma        ISSN: 0976-5662


  18 in total

1.  Femoral head size is a risk factor for total hip luxation: a study of 42,987 primary hip arthroplasties from the Norwegian Arthroplasty Register.

Authors:  Sven Byström; Birgitte Espehaug; Ove Furnes; Leif I Havelin
Journal:  Acta Orthop Scand       Date:  2003-10

2.  Quality of life and functional outcome after primary total hip replacement. A five-year follow-up.

Authors:  C Y Ng; J A Ballantyne; I J Brenkel
Journal:  J Bone Joint Surg Br       Date:  2007-07

3.  The use of the Oxford hip and knee scores.

Authors:  D W Murray; R Fitzpatrick; K Rogers; H Pandit; D J Beard; A J Carr; J Dawson
Journal:  J Bone Joint Surg Br       Date:  2007-08

4.  Radiological demarcation of cemented sockets in total hip replacement.

Authors:  J G DeLee; J Charnley
Journal:  Clin Orthop Relat Res       Date:  1976 Nov-Dec       Impact factor: 4.176

5.  Lower rates of dislocation with increased femoral head size after primary total hip replacement: a five-year analysis of NHS patients in England.

Authors:  S S Jameson; D Lees; P James; I Serrano-Pedraza; P F Partington; S D Muller; R M D Meek; M R Reed
Journal:  J Bone Joint Surg Br       Date:  2011-07

6.  Ectopic ossification following total hip replacement. Incidence and a method of classification.

Authors:  A F Brooker; J W Bowerman; R A Robinson; L H Riley
Journal:  J Bone Joint Surg Am       Date:  1973-12       Impact factor: 5.284

7.  Ceramic bearings for total hip arthroplasty have high survivorship at 10 years.

Authors:  James A D'Antonio; William N Capello; Marybeth Naughton
Journal:  Clin Orthop Relat Res       Date:  2012-02       Impact factor: 4.176

8.  Alumina on alumina versus metal on conventional polyethylene: a randomized clinical trial with 9 to 15 years follow-up.

Authors:  Pascal-André Vendittoli; Charles Rivière; Martin Lavigne; Pauline Lavoie; Ahmed Alghamdi; Nicolas Duval
Journal:  Acta Orthop Belg       Date:  2013-04       Impact factor: 0.500

9.  Wear performance of large-diameter differential-hardness hip bearings.

Authors:  C Lowry Barnes; David DeBoer; R Scott Corpe; Satya Nambu; Michael Carroll; Irina Timmerman
Journal:  J Arthroplasty       Date:  2008-09       Impact factor: 4.757

10.  Clinical outcomes assessment of three similar hip arthroplasty bearing surfaces.

Authors:  Christopher Parsons; Ryan Batson; Shane Reighard; Stephanie Tanner; Becky Snider; Thomas B Pace
Journal:  Orthop Rev (Pavia)       Date:  2014-05-22
View more
  1 in total

1.  Satisfaction and Health-Related Quality of Life Following Hip and Knee Arthroplasty Surgeries in Indian Patients: A Cross-Sectional Study.

Authors:  Ramesh K Sen; Veeresh Shetti; Reet Mukhopadhyay; Sujit Kumar Tripathy; Gaurav Saini; Sagar Kadam Dip; Neha Raman; Monica Rana; Kamini Vashishta; Suresh Kumar Sharma
Journal:  Indian J Orthop       Date:  2022-01-18       Impact factor: 1.033

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.