Literature DB >> 21705556

Lower rates of dislocation with increased femoral head size after primary total hip replacement: a five-year analysis of NHS patients in England.

S S Jameson1, D Lees, P James, I Serrano-Pedraza, P F Partington, S D Muller, R M D Meek, M R Reed.   

Abstract

Increased femoral head size may reduce dislocation rates following total hip replacement. The National Joint Registry for England and Wales has highlighted a statistically significant increase in the use of femoral heads ≥ 36 mm in diameter from 5% in 2005 to 26% in 2009, together with an increase in the use of the posterior approach. The aim of this study was to determine whether rates of dislocation have fallen over the same period. National data for England for 247 546 procedures were analysed in order to determine trends in the rate of dislocation at three, six, 12 and 18 months after operation during this time. The 18-month revision rates were also examined. Between 2005 and 2009 there were significant decreases in cumulative dislocations at three months (1.12% to 0.86%), six months (1.25% to 0.96%) and 12 months (1.42% to 1.11%) (all p < 0.001), and at 18 months (1.56% to 1.31%) for the period 2005 to 2008 (p < 0.001). The 18-month revision rates did not significantly change during the study period (1.26% to 1.39%, odds ratio 1.10 (95% confidence interval 0.98 to 1.24), p = 0.118). There was no evidence of changes in the coding of dislocations during this time. These data have revealed a significant reduction in dislocations associated with the use of large femoral head sizes, with no change in the 18-month revision rate.

Entities:  

Mesh:

Year:  2011        PMID: 21705556     DOI: 10.1302/0301-620X.93B7.26657

Source DB:  PubMed          Journal:  J Bone Joint Surg Br        ISSN: 0301-620X


  51 in total

1.  The Frank Stinchfield Award: Dislocation in revision THA: do large heads (36 and 40 mm) result in reduced dislocation rates in a randomized clinical trial?

Authors:  Donald S Garbuz; Bassam A Masri; Clive P Duncan; Nelson V Greidanus; Eric R Bohm; Martin J Petrak; Craig J Della Valle; Allan E Gross
Journal:  Clin Orthop Relat Res       Date:  2012-02       Impact factor: 4.176

2.  Ideal femoral head size in total hip arthroplasty balances stability and volumetric wear.

Authors:  Michael B Cross; Denis Nam; David J Mayman
Journal:  HSS J       Date:  2012-09-13

3.  Efficacy of revision surgery for the dislocating total hip arthroplasty: report from a large community registry.

Authors:  Tiare Salassa; Daniel Hoeffel; Susan Mehle; Penny Tatman; Terence J Gioe
Journal:  Clin Orthop Relat Res       Date:  2013-10-23       Impact factor: 4.176

4.  Comparative effectiveness of ceramic-on-ceramic implants in stemmed hip replacement: a multinational study of six national and regional registries.

Authors:  Art Sedrakyan; Stephen Graves; Barbara Bordini; Miquel Pons; Leif Havelin; Susan Mehle; Elizabeth Paxton; Thomas Barber; Guy Cafri
Journal:  J Bone Joint Surg Am       Date:  2014-12-17       Impact factor: 5.284

5.  Choice of approach, but not femoral head size, affects revision rate due to dislocations in THA after femoral neck fracture: results from the Lithuanian Arthroplasty Register.

Authors:  Algimantas Cebatorius; Otto Robertsson; Justinas Stucinskas; Alfredas Smailys; Linas Leonas; Sarunas Tarasevicius
Journal:  Int Orthop       Date:  2014-12-16       Impact factor: 3.075

6.  Using nonlinear finite element models to analyse stress distribution during subluxation and torque required for dislocation of newly developed total hip structure after prosthetic impingement.

Authors:  Wei-Min Chi; Chien-Chung Lin; Ying-Jui Ho; Hsiao-Che Lin; Jian-Horng Chen
Journal:  Med Biol Eng Comput       Date:  2017-07-01       Impact factor: 2.602

Review 7.  [Use of dual mobility cups for revision hip arthroplasty].

Authors:  E Röhner; G Matziolis
Journal:  Orthopade       Date:  2017-02       Impact factor: 1.087

Review 8.  Biomechanical concept and clinical outcome of dual mobility cups.

Authors:  Aron Grazioli; Eugene Teow Hin Ek; Hannes Andreas Rüdiger
Journal:  Int Orthop       Date:  2012-10-17       Impact factor: 3.075

9.  No difference in gait recovery after THA with different head diameters: a prospective randomized study.

Authors:  Luigi Zagra; Federica Anasetti; Luca Bianchi; Vittorio Licari; Roberto Giacometti Ceroni
Journal:  Clin Orthop Relat Res       Date:  2013-12       Impact factor: 4.176

10.  Use of dual-mobility cup in revision hip arthroplasty reduces the risk for further dislocation: analysis of seven hundred and ninety one first-time revisions performed due to dislocation, reported to the Swedish Hip Arthroplasty Register.

Authors:  Maziar Mohaddes; Peter Cnudde; Ola Rolfson; Alexander Wall; Johan Kärrholm
Journal:  Int Orthop       Date:  2017-01-11       Impact factor: 3.075

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.