Literature DB >> 18722303

Wear performance of large-diameter differential-hardness hip bearings.

C Lowry Barnes1, David DeBoer, R Scott Corpe, Satya Nambu, Michael Carroll, Irina Timmerman.   

Abstract

We hypothesized that differential-hardness hard-on-hard bearings would generate less wear debris compared with like-hardness metal-on-metal (M-o-M) bearings. We conducted wear testing on 3 types of large-diameter hard hip bearings: (1) contemporary cast-on-cast ("like" hardness) M-o-M; (2) differential-hardness M-o-M; and (3) differential-hardness ceramic-on-metal. A simulated gait profile ranging from 200 to 2000 N was applied to the bearings at a frequency of 1 Hz for 5 Mc. All bearings were tested in an anatomically inverted position in 90% alpha calf serum. Both differential-hardness bearing systems produced lower run-in wear rates (90%-97%), steady-state wear rate (45%-84%), and total metal wear (68%-88%) compared with the like-hardness bearing system. The ceramic-on-metal bearings exhibited the least wear followed by differential-hardness M-o-M bearings; like-hardness M-o-M bearings exhibited the greatest amount of wear. These findings support our hypothesis that differential-hardness hip bearing systems produce less metallic wear debris than those with like hardness and may result in lower metal ion release in vivo.

Entities:  

Mesh:

Substances:

Year:  2008        PMID: 18722303     DOI: 10.1016/j.arth.2008.05.021

Source DB:  PubMed          Journal:  J Arthroplasty        ISSN: 0883-5403            Impact factor:   4.757


  5 in total

1.  Low incidence of groin pain and early failure with large metal articulation total hip arthroplasty.

Authors:  John B Meding; Lindsey K Meding; E Michael Keating; Michael E Berend
Journal:  Clin Orthop Relat Res       Date:  2012-02       Impact factor: 4.176

2.  No Difference in Reoperations at 2 Years Between Ceramic-on-metal and Metal-on-metal THA: A Randomized Trial.

Authors:  C Anderson Engh; Supatra Sritulanondha; Abigail Korczak; Terrence David Whalen; Douglas D R Naudie; Richard W McCalden; Steven J MacDonald
Journal:  Clin Orthop Relat Res       Date:  2016-02       Impact factor: 4.176

3.  In vitro evaluation of stiffness graded artificial hip joint femur head in terms of joint stresses distributions and dimensions: finite element study.

Authors:  H Fouad
Journal:  J Mater Sci Mater Med       Date:  2011-04-20       Impact factor: 3.896

4.  Wear performance of ceramic-on-metal hip bearings.

Authors:  Jörn Reinders; Robert Sonntag; Christian Heisel; Tobias Reiner; Leo Vot; Jan Philippe Kretzer
Journal:  PLoS One       Date:  2013-08-29       Impact factor: 3.240

5.  Patient satisfaction related outcome after total hip arthroplasty; does bearing surface play a role?

Authors:  Shubhranshu S Mohanty; Hariharan Mohan; Tushar N Rathod; Prashant Kamble
Journal:  J Clin Orthop Trauma       Date:  2020-01-03