Prospective evaluation of the setup errors and its impact on safety margin for cervical cancer pelvic conformal radiotherapy.

Avinash Badajena1, Vijay Parshuram Raturi2, Kirti Sirvastava1, Hidehiro Hojo2, Hajime Ohyoshi2, Yanping Bei2, Toshiya Rachi2, Chen-Ta Wu3, Taku Tochinai2, Masayuki Okumura2, Haiqin Zhang2, Hirotaki Kouta2, Pragya Verma1, Geeta Singh1, Abhishek Anand1, Anjali Sachan1.   

Abstract

AIM: The primary objective was to assess set-up errors (SE) and secondary objective was to determine optimal safety margin (SM).
BACKGROUND: To evaluate the SE and its impact on the SM utilizing electronic portal imaging (EPI) for pelvic conformal radiotherapy.
MATERIAL AND METHODS: 20 cervical cancer patients were enrolled in this prospective study. Supine position with ankle and knee rest was used during CT simulation. The contouring was done using consensus guideline for intact uterus. 50 Gy in 25 fractions were delivered at the isocenter with ≥95% PTV coverage. Two orthogonal (Anterior and Lateral) digitally reconstructed radiograph (DRR) was constructed as a reference image. The pair of orthogonal [Anterior-Posterior and Right Lateral] single exposure EPIs during radiation was taken. The reference DRR and EPIs were compared for shifts, and SE was calculated in the X-axis, Y-axis, and Z-axis directions.
RESULTS: 320 images (40 DRRs and 280 EPIs) were assessed. The systematic error in the Z-axis (AP EPI), X-axis (AP EPI), and Y-axis (Lat EPI) ranged from -12.0 to 11.8 mm, -10.3 to 7.5 mm, and -8.50 to 9.70 mm, while the random error ranged from 1.60 to 6.15 mm, 0.59 to 4.93 mm, and 1.02 to -4.35 mm. The SM computed were 7.07, 6.36, and 7.79 mm in the Y-axis, X-axis, and Z-axis by Van Herk's equation, and 6.0, 5.51, and 6.74 mm by Stroom's equation.
CONCLUSION: The computed SE helps defining SM, and it may differ between institutions. In our study, the calculated SM was approximately 8 mm in the Z-axis, 7 mm in X and Y axis for pelvic conformal radiotherapy.
© 2020 Greater Poland Cancer Centre. Published by Elsevier B.V. All rights reserved.

Entities:  

Keywords:  Pelvic conformal radiotherapy; Set-up errors; Set-up margin

Year:  2020        PMID: 32140083      PMCID: PMC7049598          DOI: 10.1016/j.rpor.2020.02.006

Source DB:  PubMed          Journal:  Rep Pract Oncol Radiother        ISSN: 1507-1367


  22 in total

1.  Improvement in total positioning error for lateral prostatic fields using a soft immobilization device.

Authors:  C Catton; L Lebar; P Warde; Y Hao; P Catton; M Gospodarowicz; M McLean; M Milosevic
Journal:  Radiother Oncol       Date:  1997-09       Impact factor: 6.280

2.  Pelvic irradiation of the obese patient: a treatment strategy involving megavoltage simulation and intratreatment setup corrections.

Authors:  K Luchka; S Shalev
Journal:  Med Phys       Date:  1996-11       Impact factor: 4.071

3.  A consensus-based guideline defining clinical target volume for primary disease in external beam radiotherapy for intact uterine cervical cancer.

Authors:  Takafumi Toita; Tatsuya Ohno; Yuko Kaneyasu; Tomoyasu Kato; Takashi Uno; Kazuo Hatano; Yoshiki Norihisa; Takahiro Kasamatsu; Takeshi Kodaira; Ryoichi Yoshimura; Satoshi Ishikura; Masahiro Hiraoka
Journal:  Jpn J Clin Oncol       Date:  2011-09       Impact factor: 3.019

4.  Quantification of organ motion during conformal radiotherapy of the prostate by three dimensional image registration.

Authors:  M van Herk; A Bruce; A P Kroes; T Shouman; A Touw; J V Lebesque
Journal:  Int J Radiat Oncol Biol Phys       Date:  1995-12-01       Impact factor: 7.038

5.  Reduction of irradiated small bowel volume and accurate patient positioning by use of a bellyboard device in pelvic radiotherapy of gynecological cancer patients.

Authors:  M Olofsen-van Acht; H van den Berg; S Quint; H de Boer; M Seven; J van Sömsen de Koste; C Creutzberg; A Visser
Journal:  Radiother Oncol       Date:  2001-04       Impact factor: 6.280

6.  Setup errors in patients treated with intensity-modulated whole pelvic radiation therapy for gynecological malignancies.

Authors:  Joshua J Haslam; Anthony E Lujan; Arno J Mundt; Dacian V Bonta; John C Roeske
Journal:  Med Dosim       Date:  2005       Impact factor: 1.482

Review 7.  Set-up verification using portal imaging; review of current clinical practice.

Authors:  C W Hurkmans; P Remeijer; J V Lebesque; B J Mijnheer
Journal:  Radiother Oncol       Date:  2001-02       Impact factor: 6.280

8.  A comparison of four patient immobilization devices in the treatment of prostate cancer patients with three dimensional conformal radiotherapy.

Authors:  P Y Song; M Washington; F Vaida; R Hamilton; D Spelbring; B Wyman; J Harrison; G T Chen
Journal:  Int J Radiat Oncol Biol Phys       Date:  1996-01-01       Impact factor: 7.038

9.  A randomized trial evaluating rigid immobilization for pelvic irradiation.

Authors:  Andrew Kneebone; Val Gebski; Nicole Hogendoorn; Sandra Turner
Journal:  Int J Radiat Oncol Biol Phys       Date:  2003-07-15       Impact factor: 7.038

10.  Clinical implementation of an objective computer-aided protocol for intervention in intra-treatment correction using electronic portal imaging.

Authors:  F Van den Heuvel; W De Neve; D Verellen; M Coghe; V Coen; G Storme
Journal:  Radiother Oncol       Date:  1995-06       Impact factor: 6.280

View more
  1 in total

1.  Enhanced Anti-Cancer Effect of Folate-Conjugated Olaparib Nanoparticles Combined with Radiotherapy in Cervical Carcinoma.

Authors:  Dong Li; Chuanfei Hu; Juan Yang; Yin Liao; Yue Chen; Shao Zhi Fu; Jing Bo Wu
Journal:  Int J Nanomedicine       Date:  2020-12-10
  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.