Clinical implementation of an objective computer-aided protocol for intervention in intra-treatment correction using electronic portal imaging.

F Van den Heuvel1, W De Neve, D Verellen, M Coghe, V Coen, G Storme.   

Abstract

In order to test the feasibility of a protocol for intra-fractional adjustment of the patient position, during radiation therapy treatment in the pelvic region, a two-fold study is carried out. The protocol involves an objective quantitative measurement of the error in positioning starting from the comparison of a portal image with a reference image. The first part of the study applies the protocol to determine the efficacy of adjustment using subjective determination of the positioning errors by a clinician by measuring the residual errors after adjustment. A group of 13 patients was followed extensively throughout their treatment, analyzing 240 fields. In the second part the measurement itself determines the extent of readjustment of the position. Throughout the procedure elapsed time is measured to determine the extra time involved in using this procedure. For this part a group of 21 patients was followed yielding statistics on 218 fields. Using this computer aided protocol it is shown that systematic as well as random errors can be reduced to standard deviations of the order of 1 mm. The price to pay however is additional treatment time up to 58% of the treatment time without the protocol. Time analysis shows that the largest part of the added time is spent on the readjustment of the patients' position adding a mean of 37% of time to the treatment of one field. This is despite the fact that the readjustment was performed using a remote couch controller. Finally a statistical analysis shows that it is possible to select patients benefiting from the use of such a protocol after a limited number of fractions.

Entities:  

Mesh:

Year:  1995        PMID: 7480827     DOI: 10.1016/0167-8140(95)01569-3

Source DB:  PubMed          Journal:  Radiother Oncol        ISSN: 0167-8140            Impact factor:   6.280


  4 in total

1.  Patient-specific daily pretreatment setup protocol using electronic portal imaging for radiation therapy.

Authors:  Michael H Wittmer; Thomas M Pisansky; Jon J Kruse; Michael G Herman
Journal:  J Appl Clin Med Phys       Date:  2005-11-21       Impact factor: 2.102

2.  Guide to clinical use of electronic portal imaging.

Authors:  M G Herman; J J Kruse; C R Hagness
Journal:  J Appl Clin Med Phys       Date:  2000       Impact factor: 2.102

3.  Prospective evaluation of the setup errors and its impact on safety margin for cervical cancer pelvic conformal radiotherapy.

Authors:  Avinash Badajena; Vijay Parshuram Raturi; Kirti Sirvastava; Hidehiro Hojo; Hajime Ohyoshi; Yanping Bei; Toshiya Rachi; Chen-Ta Wu; Taku Tochinai; Masayuki Okumura; Haiqin Zhang; Hirotaki Kouta; Pragya Verma; Geeta Singh; Abhishek Anand; Anjali Sachan
Journal:  Rep Pract Oncol Radiother       Date:  2020-02-22

4.  A comparison of computer-controlled versus manual on-line patient setup adjustment.

Authors:  Kristy K Brock; Daniel L McShan; James M Balter
Journal:  J Appl Clin Med Phys       Date:  2002       Impact factor: 2.102

  4 in total