| Literature DB >> 32042440 |
Hao-Zhen Lyu1, Jae Hyup Lee1,2.
Abstract
BACKGROUND: In dental or orthopedic surgery, bone substitutes are inserted with implants to promote osteogenesis and enhance osseointegration. The purpose of this research was to evaluate the efficacy of rhBMP-2 (recombinant human bone morphogenetic protein-2) loaded hydrogel composite for bone formation around dental implant in minipig mandible bone defect models.Entities:
Keywords: Bone morphogenetic protein-2; Hydrogel; Minipig; Osseointegration; Osteogenesis
Year: 2020 PMID: 32042440 PMCID: PMC6998194 DOI: 10.1186/s40824-020-0183-9
Source DB: PubMed Journal: Biomater Res ISSN: 1226-4601
Fig. 1Radiograph finding. The white arrows indicate the radiolucent shading area around the implants. a The implant group; b The hydrogel group; c The rhBMP-2 group
Fig. 2Percent of bone volume (BV/TV) and trabecular number (Tb.N) by micro-CT analysis. a BV/TV: implant vs rhBMP-2, P = 0.055; b Tb.N: implant vs rhBMP-2, P = 0.055
Micro-CT results for osteogenesis around implants
| Group( | BV/TV | BS/BV | Tb.N | Tb.Th | Tb.Sp | Tb.Pf |
|---|---|---|---|---|---|---|
| Implant group | 0.80 ± 0.19 | 315.09 ± 21.10 | 0.28 ± 0.07 | 0.03 ± 0.00 | 0.34 ± 0.04 | 70.76 ± 8.04 |
| Hydrogel group | 1.59 ± 1.38 | 288.27 ± 54.68 | 0.55 ± 0.47 | 0.03 ± 0.00 | 0.31 ± 0.06 | 56.71 ± 21.30 |
| rhBMP-2 group | 1.91 ± 1.54 | 286.31 ± 42.49 | 0.66 ± 0.52 | 0.03 ± 0.00 | 0.29 ± 0.07 | 54.03 ± 18.91 |
| 0.055 | 0.228 | 0.055 | 0.599 | 0.106 | 0.04 |
Values are presented as mean ± standard deviation
P-value: the rhBMP-2 group vs the implant group
BV/TV (%) percent bone volume (bone volume/total volume), BS/BV (1/mm) bone surface/bone volume, Tb.Pf (1/mm) trabecular bone pattern factor, Tb.Th (mm) trabecular thickness, Tb.N (1/mm) trabecular number, Tb.Sp (mm) trabecular separation
Histological results for osteointegration
| Group ( | Bone to implant contact ratio | Bone to implant area ratio |
|---|---|---|
| Implant group | 2.92 ± 8.59 | 6.96 ± 13.43 |
| Hydrogel group | 1.19 ± 5.83 | 2.42 ± 7.51 |
| rhBMP-2 group | 3.40 ± 4.27 | 13.92 ± 12.34* |
Values are presented as mean ± standard deviation
*Significantly greater than the hydrogel group (P < 0.05)
Fig. 3Micro-CT finding. The newly formed bone in the rhBMP-2 group is more than that in the other groups. The green arrows indicate new bone that growth into the implant threads. The green triangles indicate the damages of host bone. a The implant group; b The hydrogel group; c The rhBMP-2 group
Fig. 4Histological finding. The implant osseointegration in the rhBMP-2 group was the best. Compared to the implant group, the osseointegration of the implant in the hydrogel group was the worst. The green arrows indicate new formed bone around the implant. Hematoxylin and eosin stain(× 40). Scale bar = 1 mm. I: implant; NB: new bone. a The implant group; b The hydrogel group; c The rhBMP-2 group