Jae Hyup Lee1, Jungju Kim, Hae-Ri Baek, Kyung Mee Lee, Jun-Hyuk Seo, Hyun-Kyung Lee, A-Young Lee, Guang Bin Zheng, Bong-Soon Chang, Choon-Ki Lee.
Abstract
Methods to improve osseointegration that include implantation of rhBMP-2 with various kinds of carriers are currently of considerable interest. The present study was conducted to evaluate if the rhBMP-2 loaded β-TCP microsphere-hyaluronic acid-based powder-like hydrogel composite (powder gel) can act as an effective rhBMP-2 carrier for implantation in host bone with a bone defect or poor bone quality. The release pattern for rhBMP-2 was then evaluated against an rhBMP-2-loaded collagen sponge as a control group. Dental implants were also inserted into the tibias of three groups of rabbits: an rhBMP-2 (200 µg) loaded powder gel composite implanted group, an implant only group, and a powder gel implanted group. Micro-CT and histology of the implanted areas were carried out four weeks later. The rhBMP-2 powder gel released less rhBMP-2 than the collagen sponge, but it continued a slow release for more than 7 days. The rhBMP-2 powder gel composite improved osseointegration of the dental implant by increasing the amount of new bone formation in the implant pitch and it improved the bone quality and bone quantity of new bone. The histology results indicated that the rhBMP-2 powder gel composite improved the osseointegration in the cortical bone as well as the marrow space along the fixture. The bone-to-implant contact ratio of the rhBMP-2 (200 µg) loaded powder gel composite implanted group was significantly higher than those of the implant only group and the powder gel implanted group. The powder gel appeared to be a good carrier and could release rhBMP-2 slowly to promote the formation of new bone following implantation in a bone defect, thereby improving implant osseointegration.Entities:
Mesh:
Substances:
Year: 2014 PMID: 24928668 PMCID: PMC4137170 DOI: 10.1007/s10856-014-5250-0
Source DB: PubMed Journal: J Mater Sci Mater Med ISSN: 0957-4530 Impact factor: 3.896
Fig. 1SEM images of β-TCP microspheres generated by the spray-dry method after sintering at 1,250 °C
Fig. 2Surgical procedures. a Tibial diaphysis in the tibial medial aspect was exposed and two, 4 mm diameter holes were generated; b A composite of rhBMP-2 loaded porous β-TCP microspheres and hyaluronic acid powder-gel was injected; c A dental implant fixture was inserted
Fig. 3a SEM images of cross-linked and freeze-dried HA-based hydrogel; b Images of the hydrated HA-based powder-gel; c Swelling ratio of the HA-based powder-gel
Fig. 4In vitro release of BMP-2 (A: Hyaluronic acid (HA)-based powder-gel; Control: collagen sponge)
Fig. 5Plane radiographs. H: A composite of the β-TCP microspheres and the hyaluronic acid powder gel was injected and a dental implant fixture was inserted (hydrogel group); B: A composite of the rhBMP-2 loaded porous β-TCP microspheres and the hyaluronic acid powder gel was injected and then a dental implant fixture was inserted (BMP-2 group). I: Only a dental implant fixture was inserted (implant group)
Fig. 6Micro-CT results. a Only a dental implant fixture was implanted (implant group); b A composite of the β-TCP microspheres and the hyaluronic acid powder gel was injected and a dental implant fixture was inserted (hydrogel group); c A composite of the rhBMP-2 loaded β-TCP microspheres and the hyaluronic acid powder gel was injected and a dental implant fixture was inserted (BMP-2 group). In panel a, new bone formation was insignificant around the implant fixture but some new bone was shown in panel b, while extensive new bone formation was observed in panel c (arrows: newly formed bony tissue)
Micro-CT results at 4 weeks after the implantation. The BMP-2 group showed significantly higher percent bone volume, trabecular number, trabecular thickness than the Implant group
| Group (n) | BV/TV | BS/BV | Tb.Pf | Tb.Th | Tb.N | Tb.Sp |
|---|---|---|---|---|---|---|
| Average (std) | ||||||
| Implant group (30) | 5.6 (1.4) | 171.6 (21.0) | 19.4 (7.4) | 0.034 (0.007) | 1.64 (0.27) | 0.20 (0.04) |
| Hydrogel group (30) | 6.7 (3.2) | 167.2 (24.2) | 19.4 (9.5) | 0.035 (0.006) | 1.89 (0.60) | 0.18 (0.05) |
| BMP-2 group (30) | 10.4 (5.3) | 146.0 (32.6) | 9.4 (13.5) | 0.042 (0.009) | 2.39 (0.85) | 0.16 (0.04) |
|
| <0.0001 | 0.0006 | 0.0007 | 0.0002 | <0.0001 | 0.002 |
P-value: Implant group and BMP-2 group
BV/TV Bone Volume/Trabecular Volume, percent bone volume
BS/BV Bone Surface/Bone Volume ratio, specific surface
Tb.Pf Trabecular Pattern factor
Tb.Th Trabecular Thickness
Tb.N Trabecular Number
Tb.Sp Trabecular Separation
Fig. 7Undecalcified histology. The image magnification on the left and right was ×12.5 and ×40, respectively. a Only a dental implant fixture was implanted (implant group). Bone coupling with cortical bone was stable, but the osseous tissue associated with the fixture screws in the marrow space was insignificant; b A composite of the β-TCP microspheres and the hyaluronic acid powder gel was injected and a dental implant fixture was inserted (hydrogel group). Bone bonding in the cortical bone was also robust, but new bone formation in the marrow space was insignificant even in comparison to the implant group. The tissue within the pitch is composed of fibrous tissue and exists as intervening tissue between the bony tissues of the marrow space; c A composite of the rhBMP-2 loaded β-TCP microspheres and the hyaluronic acid powder gel was injected and a dental implant fixture was inserted (BMP-2 group). The bone bonding in the cortical bone was stable and osseous tissue was connected from the cortical bone to the marrow space. Newly formed bone was evident around the fixture within the marrow space, and newly formed bone was fused with the fixture