Literature DB >> 12582800

Osteosynthesis of distal radial fractures with a volar locking screw plate system.

H Drobetz1, E Kutscha-Lissberg.   

Abstract

We developed a locking screw plate system for the stabilisation of distal radial fractures, which can be inserted through a standard volar approach and in which the locking mechanism allows early post-operative mobilisation. Forty-nine patients with 50 fractures underwent surgical treatment; 66% were type C fractures. The mean follow-up was 26 months. According to the scores of Gartland and Werley and Green and O'Brien, 92% and 68% respectively had an excellent or good outcome; 46% were radiologically identical to the uninjured side and in 42% the reduction remained unchanged after 2 years. The most frequent complication was rupture of the flexor pollicis longus tendon, which occurred in six cases (12%) at a mean of 10 months after operation.

Entities:  

Mesh:

Year:  2002        PMID: 12582800      PMCID: PMC3673689          DOI: 10.1007/s00264-002-0393-x

Source DB:  PubMed          Journal:  Int Orthop        ISSN: 0341-2695            Impact factor:   3.075


  66 in total

Review 1.  [Is routine implant removal after trauma surgery sensible?].

Authors:  C Krettek; C Müller; R Meller; M Jagodzinski; F Hildebrand; R Gaulke
Journal:  Unfallchirurg       Date:  2012-04       Impact factor: 1.000

2.  Anatomical and radiological study applied to distal radius surgery.

Authors:  N Gasse; D Lepage; R Pem; C Bernard; J M Lerais; P Garbuio; L Obert
Journal:  Surg Radiol Anat       Date:  2010-12-07       Impact factor: 1.246

3.  Rupture of Flexor Pollicis Longus Tendon: A Complication of Volar Locking Plating of the Distal Radius.

Authors:  Aysha Sethunathan Rajeev; Shanaka Sreverthana; John Harrison
Journal:  Eur J Trauma Emerg Surg       Date:  2009-09-11       Impact factor: 3.693

4.  Comparison of external fixation, locking and non-locking palmar plating for unstable distal radius fractures in the elderly.

Authors:  N Schmelzer-Schmied; P Wieloch; A K Martini; W Daecke
Journal:  Int Orthop       Date:  2008-01-12       Impact factor: 3.075

5.  The importance of pronator quadratus repair in the treatment of distal radius fractures with volar plating.

Authors:  Zahab S Ahsan; Jeffrey Yao
Journal:  Hand (N Y)       Date:  2012-09

6.  Older Patient Preferences for Internal Fixation after a Distal Radius Fracture: A Qualitative Study from the Wrist and Radius Injury Surgical Trial.

Authors:  Jacob S Nasser; Helen E Huetteman; Melissa J Shauver; Kevin C Chung
Journal:  Plast Reconstr Surg       Date:  2018-07       Impact factor: 4.730

7.  [Intraoperative virtual implant planning for volar plate osteosynthesis of distal radius fractures].

Authors:  J Franke; S Y Vetter; K Reising; S Herrmann; N P Südkamp; P A Grützner; J von Recum
Journal:  Unfallchirurg       Date:  2016-01       Impact factor: 1.000

Review 8.  Hand Surgeon Reporting of Tendon Rupture Following Distal Radius Volar Plating.

Authors:  Nathan A Monaco; C Liam Dwyer; Alex J Ferikes; John D Lubahn
Journal:  Hand (N Y)       Date:  2016-02-19

9.  Anomalous Courses of the Palmar Cutaneous Branch of the Median Nerve in Relation to the Flexor Carpi Radialis Tendon for ORIF of Distal Radius Fractures.

Authors:  Steven Z Glickel; Sara M Glynn; Andy L Chang; Jessie W Janowski; O Alton Barron; Louis W Catalano
Journal:  Hand (N Y)       Date:  2019-01-31

10.  [Unidirectional versus multidirectional palmar locking osteosynthesis of unstable distal radius fractures: comparative analysis with LDR 2.4 mm versus 2.7 mm matrix-Smartlock].

Authors:  M Hakimi; P Jungbluth; S Gehrmann; J Nowak; J Windolf; M Wild
Journal:  Unfallchirurg       Date:  2010-03       Impact factor: 1.000

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.