Literature DB >> 16505728

Current concepts in volar fixed-angle fixation of unstable distal radius fractures.

Jorge L Orbay1, Amel Touhami.   

Abstract

UNLABELLED: We present new developments in the volar treatment of unstable distal radius fractures in adults. New perspectives on the anatomy of the wrist, the watershed line on the volar radius and the usefulness of the pronator fossa are presented and these help to avoid flexor and extensor tendon disturbance when using a volar approach. Other new insights on the bony anatomy of the distal end of the radius are discussed, which are important in improving the quality of fracture fixation, including the benefits of constructing a precise fixed-angle scaffold underneath the articular surface in order to stabilize it. A volar fixed-angle plate must support the dorsal, central and volar aspects of the subchondral bone in order to stabilize the most complex fractures. Awareness of the anatomy of blood supply to the distal radius: the dorsal retinaculum that feeds the distal fragments and the blood supply to the diaphysis through branches of the anterior interosseous artery is necessary to maximize healing potential and avoid complications. Volar fixed-angle plates need to withstand very high forces during rehabilitation, the magnitude of these forces are up to five times the loads applied on the hand. LEVEL OF EVIDENCE: Level V (expert opinion).

Entities:  

Mesh:

Year:  2006        PMID: 16505728     DOI: 10.1097/01.blo.0000205891.96575.0f

Source DB:  PubMed          Journal:  Clin Orthop Relat Res        ISSN: 0009-921X            Impact factor:   4.176


  45 in total

1.  Flexor pollicis longus tendon rupture by sandwiched underlying volar locking plate and distal radius.

Authors:  Takuya Uemura; Tadashi Okano; Ema Onode; Takuya Yokoi; Kosuke Shintani; Mitsuhiro Okada; Hiroaki Nakamura
Journal:  J Med Ultrason (2001)       Date:  2018-04-27       Impact factor: 1.314

Review 2.  Management of complications of distal radius fractures.

Authors:  Alexandra L Mathews; Kevin C Chung
Journal:  Hand Clin       Date:  2015-02-28       Impact factor: 1.907

3.  Complex fractures of the distal radius treated with angular stability plates.

Authors:  Marco Frattini; Giovanni Soncini; Maurizio Corradi; Bruno Panno; Silvio Tocco; Francesco Pogliacomi
Journal:  Chir Organi Mov       Date:  2009-07-21

4.  Morphology of distal radius curvatures: a CT-based study on the Malaysian Malay population.

Authors:  Taran Singh Pall Singh; Abdul Nawfar Sadagatullah; Abdul Halim Yusof
Journal:  Singapore Med J       Date:  2015-10       Impact factor: 1.858

5.  Investigating the minimum distance between the finger flexor tendons and distal radius during wrist and finger positions in healthy people.

Authors:  Kanta Imao; Hitoshi Miwa; Kazutoshi Watanabe; Tsuyoshi Satoh; Atsuki Sano; Naoto Endo
Journal:  J Med Ultrason (2001)       Date:  2019-03-06       Impact factor: 1.314

6.  Volar Distal Radius Anatomy Applied to the Treatment of Distal Radius Fracture.

Authors:  Junya Imatani; Keiichi Akita
Journal:  J Wrist Surg       Date:  2017-06-27

Review 7.  Hand Surgeon Reporting of Tendon Rupture Following Distal Radius Volar Plating.

Authors:  Nathan A Monaco; C Liam Dwyer; Alex J Ferikes; John D Lubahn
Journal:  Hand (N Y)       Date:  2016-02-19

8.  Repositioning and stabilization of the radial styloid process in comminuted fractures of the distal radius using a single approach: the radio-volar double plating technique.

Authors:  Matthias Jacobi; Peter Wahl; Georges Kohut
Journal:  J Orthop Surg Res       Date:  2010-08-11       Impact factor: 2.359

9.  [Design of distal radius volar locking plates : Anatomical, surgical and biomechanical aspects].

Authors:  M Wich; R Sixto; N Spranger
Journal:  Unfallchirurg       Date:  2016-09       Impact factor: 1.000

10.  Different osteosyntheses for Colles' fracture: a mechanical study in 42 cadaver bones.

Authors:  Yngvar Krukhaug; Nils R Gjerdet; Odd J Lundberg; Peer K Lilleng; Leiv M Hove
Journal:  Acta Orthop       Date:  2009-04       Impact factor: 3.717

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.