BACKGROUND: Acetabular component position alone has not been predictive of stability after total hip arthroplasty (THA). Combined anteversion of the acetabulum and femur has the potential of being more predictive of stability. Unfortunately, femoral component position is difficult to measure on plain radiographs. Computed tomography (CT) is the gold standard for measuring implant position post-operatively, but CT exposes patients to a substantial amount of radiation. QUESTIONS/PURPOSES: We sought to determine whether biplanar low-dose radiography can be used to accurately measure both acetabular and femoral implant position after THA.
METHODS: Twenty patients underwent standing low-dose biplanar spine-to-ankle radiographs and supine CT scans 6 weeks after THA. Measurements of acetabular inclination, acetabular anteversion, and femoral anteversion were performed by two blinded observers and compared.
RESULTS: The average absolute differences between biplanar radiographs and CT scans were 2° ± 2° for acetabular inclination, 3° ± 2° for acetabular anteversion, and 4° ± 4° for femoral anteversion between EOS measurements and CT measurements. Interobserver agreement was good for acetabular inclination, acetabular anteversion, and femoral anteversion (Cronbach's α = 0.90) using biplanar low-dose imaging.
CONCLUSION: Biplanar radiography is a reliable low-radiation alternative for measuring acetabular inclination, acetabular anteversion, femoral version, and thus combined anteversion compared to CT. Femoral anteversion had the most variability but is still clinically relevant. © Hospital for Special Surgery 2019.

Entities:  

Keywords:  anteversion; computed tomography; imaging; implant position; total hip arthroplasty

Year:  2019        PMID: 32015737      PMCID: PMC6974156          DOI: 10.1007/s11420-018-09659-7

Source DB:  PubMed          Journal:  HSS J        ISSN: 1556-3316


  33 in total

1.  Measuring acetabular component version after THA: CT or plain radiograph?

Authors:  Benjamin McArthur; Michael Cross; Christina Geatrakas; David Mayman; Bernard Ghelman
Journal:  Clin Orthop Relat Res       Date:  2012-03-01       Impact factor: 4.176

2.  Assessment of two-dimensional (2D) and three-dimensional (3D) lower limb measurements in adults: Comparison of micro-dose and low-dose biplanar radiographs.

Authors:  Andrea B Rosskopf; Christian W A Pfirrmann; Florian M Buck
Journal:  Eur Radiol       Date:  2016-01-06       Impact factor: 5.315

3.  Total Hip Arthroplasty Patients With Fixed Spinopelvic Alignment Are at Higher Risk of Hip Dislocation.

Authors:  Christina I Esposito; Kaitlin M Carroll; Peter K Sculco; Douglas E Padgett; Seth A Jerabek; David J Mayman
Journal:  J Arthroplasty       Date:  2017-12-13       Impact factor: 4.757

4.  Validation of a computer navigation system and a CT method for determination of the orientation of implanted acetabular cup in total hip arthroplasty: a cadaver study.

Authors:  Fang Lin; Dohyung Lim; Richard L Wixson; Steven Milos; Ronald W Hendrix; Mohsen Makhsous
Journal:  Clin Biomech (Bristol, Avon)       Date:  2008-06-09       Impact factor: 2.063

5.  Reliability of a new method for evaluating femoral stem positioning after total hip arthroplasty based on stereoradiographic 3D reconstruction.

Authors:  Benjamin Guenoun; Firass El Hajj; David Biau; Philippe Anract; Jean-Pierre Courpied
Journal:  J Arthroplasty       Date:  2014-08-02       Impact factor: 4.757

6.  Is the acetabular cup orientation after total hip arthroplasty on a two dimension or three dimension model accurate?

Authors:  Benjamin Craiovan; Tobias Renkawitz; Markus Weber; Joachim Grifka; Lutz Nolte; Guoyan Zheng
Journal:  Int Orthop       Date:  2014-04-16       Impact factor: 3.075

7.  Dislocations after total hip-replacement arthroplasties.

Authors:  G E Lewinnek; J L Lewis; R Tarr; C L Compere; J R Zimmerman
Journal:  J Bone Joint Surg Am       Date:  1978-03       Impact factor: 5.284

8.  Does total hip arthroplasty restore native hip anatomy? three-dimensional reconstruction analysis.

Authors:  Tsung-Yuan Tsai; Dimitris Dimitriou; Guoan Li; Young-Min Kwon
Journal:  Int Orthop       Date:  2014-06-26       Impact factor: 3.075

9.  Measuring femoral and rotational alignment: EOS system versus computed tomography.

Authors:  D Folinais; P Thelen; C Delin; C Radier; Y Catonne; J Y Lazennec
Journal:  Orthop Traumatol Surg Res       Date:  2013-07-19       Impact factor: 2.256

10.  Outcome of extensive varus and valgus stem alignment in short-stem THA: clinical and radiological analysis using EBRA-FCA.

Authors:  Karl Philipp Kutzner; Tobias Freitag; Stefanie Donner; Mark Predrag Kovacevic; Ralf Bieger
Journal:  Arch Orthop Trauma Surg       Date:  2017-02-02       Impact factor: 3.067

View more
  4 in total

1.  A review of plain radiographic methods for measuring femoral version after total hip arthroplasty and validation of modified Budin's method in Indian population.

Authors:  Anurag Mittal; Nitish Kumar; Bobby Nandimandalam; Amite Pankaj
Journal:  J Clin Orthop Trauma       Date:  2020-10-13

2.  Validity of the EOS-determined pelvic parameters and orientation with pelvic positional variation: a phantom study.

Authors:  Jung-Taek Kim; Dong Hoon Lee; Han-Dong Lee; Han-Bit Shin; Bumhee Park; Sunghoon Park; Hyung Keun Song
Journal:  Sci Rep       Date:  2021-05-17       Impact factor: 4.379

Review 3.  The role of the femoral component orientation on dislocations in THA: a systematic review.

Authors:  Joost H J van Erp; Thom E Snijders; Harrie Weinans; René M Castelein; Tom P C Schlösser; Arthur de Gast
Journal:  Arch Orthop Trauma Surg       Date:  2021-06-08       Impact factor: 2.928

4.  The Impingement-free, Prosthesis-specific, and Anatomy-adjusted Combined Target Zone for Component Positioning in THA Depends on Design and Implantation Parameters of both Components.

Authors:  Karl-Heinz Widmer
Journal:  Clin Orthop Relat Res       Date:  2020-08       Impact factor: 4.755

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.