| Literature DB >> 31970123 |
Jun Yi Lee1, Yeorae Kim2, In Sook Sohn1, You Jung Han3, Jin Hoon Chung3, Moon Young Kim3, Min Hyoung Kim4, Hyun-Mee Ryu5, SungHong Joo6, Jung Yeol Han6.
Abstract
OBJECTIVE: To increase the rate of successful external cephalic version (ECV) and to minimize the complications, it is important to identify the predictors of success. Therefore, the purpose of this study was to investigate whether the height of the elevated fetal buttock (HOB) is a valuable predictor of successful ECV or not.Entities:
Keywords: Breech presentation; External cephalic version; Predictive value
Year: 2019 PMID: 31970123 PMCID: PMC6962591 DOI: 10.5468/ogs.2020.63.1.13
Source DB: PubMed Journal: Obstet Gynecol Sci ISSN: 2287-8572
Fig. 1Measurement of height of the elevated fetal buttock (HOB). (A) HOB by an operator's hand was measured from the maternal symphysis pubis under ultrasonography. (B) A compass and a ruler for measurement. (C) Symphysis pubis seen on ultrasonography.
Demographics and prediction factors for successful external cephalic version (ECV)
| Characteristics | Successful ECV (n=114) | Failed ECV (n=25) | ||
|---|---|---|---|---|
| Maternal age (yr) | 34.0±4.2 | 33.1±4.1 | 0.335 | |
| Parity | 0.54 | 0.08 | 0.001 | |
| Gestational age (wk) | 37.47±0.69 | 37.44±0.64 | 0.836 | |
| Estimated birth weight (g) | 2,907±317 | 2,857±237 | 0.469 | |
| Maternal height (cm) | 162.46±5.33 | 164.12±5.13 | 0.157 | |
| Maternal weight (kg) | 67.39±9.03 | 70.32±10.09 | 0.152 | |
| Maternal body mass (kg/m2) | 25.47±3.18 | 26.20±3.18 | 0.303 | |
| Presence of myoma | 0.041 | |||
| Yes | 2 (1.8) | 3 (12.0) | ||
| No | 112 (98.2) | 22 (88.0) | ||
| Location of placenta | 0.862 | |||
| Anterior | 14 (17.5) | 66 (82.5) | ||
| Posterior | 11 (18.6) | 48 (81.4) | ||
| Breech category | 0.503 | |||
| Frank | 67 (58.8) | 16 (64.0) | ||
| Complete | 28 (24.6) | 7 (28.0) | ||
| Incomplete | 19 (16.7) | 2 (8.0) | ||
| Tocolysis | 0.083 | |||
| Yes | 113 (99.1) | 23 (92.0) | ||
| No | 1 (0.9) | 2 (8.0) | ||
| Uterine contraction on admission | 0.192 | |||
| Regular | 5 (4.4) | 3 (12.0) | ||
| Irregular | 70 (61.4) | 17 (68.0) | ||
| None | 39 (34.2) | 5 (20.0) | ||
| Epidural analgesia | 0.689 | |||
| Yes | 104 (91.2) | 24 (96.0) | ||
| No | 10 (8.8) | 1 (4.0) | ||
| Amniotic fluid Index (cm) | 11.96±3.03 | 10.20±2.86 | 0.009 | |
| Height of elevated fetal buttock (cm) | 7.30±1.54 | 6.20±1.10 | 0.001 | |
Data are shown as mean±standard deviation or number (%).
Logistic regression analysis for prediction factors of successful external cephalic version
| Characteristics | OR (95% CI) | ||
|---|---|---|---|
| Parity | |||
| Nulliparity | 1 | ||
| Multiparity | 10.80 (1.57–74.94) | 0.016 | |
| Presence of myoma | |||
| No | 1 | ||
| Yes | 0.11 (0.01–1.24) | 0.073 | |
| Amniotic fluid index | |||
| ≤10.0 cm (25 percentile) | 1 | ||
| 10.1–13.9 cm (>25–<75 percentile) | 2.23 (0.75–6.60) | 0.149 | |
| ≥14.0 cm (75 percentile) | 5.26 (1.06–26.19) | 0.043 | |
| Height of elevated fetal buttock | |||
| ≤6.0 cm (25 percentile) | 1 | ||
| 6.1–7.7 cm (>25–<75 percentile) | 2.42 (0.70–8.44) | 0.164 | |
| ≥7.8 cm (75 percentile) | 10.50 (1.03–107.12) | 0.047 | |
OR, odds ratio; CI, confidence interval.
Fig. 2Receiver operating characteristics curve and AUC for validity test with HOB, parity, AFI for prediction of successful external cephalic version.
AUC, areas under the curve; SE, standard error; CI, confidence interval; AFI, amniotic fluid index; HOB, height of elevated fetal buttock.