Literature DB >> 31954232

In vivo imaging of calcium and glutamate responses to intracortical microstimulation reveals distinct temporal responses of the neuropil and somatic compartments in layer II/III neurons.

James R Eles1, Takashi D Y Kozai2.   

Abstract

OBJECTIVE: Intracortical microelectrode implants can generate a tissue response hallmarked by glial scarring and neuron cell death within 100-150 μm of the biomaterial device. Many have proposed that any performance decline in intracortical microstimulation (ICMS) due to this foreign body tissue response could be offset by increasing the stimulation amplitude. The mechanisms of this approach are unclear, however, as there has not been consensus on how increasing amplitude affects the spatial and temporal recruitment patterns of ICMS. APPROACH: We clarify these unknowns using in vivo two-photon imaging of mice transgenically expressing the calcium sensor GCaMP6s in Thy1 neurons or virally expressing the glutamate sensor iGluSnFr in neurons. Calcium and neurotransmitter activity are tracked in the neuronal somas and neuropil during long-train stimulation in Layer II/III of somatosensory cortex. MAIN
RESULTS: Neural calcium activity and glutamate release are dense and strongest within 20-40 μm around the electrode, falling off with distance from the electrode. Neuronal calcium increases with higher amplitude stimulations. During prolonged stimulation trains, a sub-population of somas fail to maintain calcium activity. Interestingly, neuropil calcium activity is 3-fold less correlated to somatic calcium activity for cells that drop-out during the long stimulation train compared to cells that sustain activity throughout the train. Glutamate release is apparent only within 20 μm of the electrode and is sustained for at least 10s after cessation of the 15 and 20 μA stimulation train, but not lower amplitudes. SIGNIFICANCE: These results demonstrate that increasing amplitude can increase the radius and intensity of neural recruitment, but it also alters the temporal response of some neurons. Further, dense glutamate release is highest within the first 20 μm of the electrode site even at high amplitudes, suggesting that there may be spatial limitations to the amplitude parameter space. The glutamate elevation outlasts stimulation, suggesting that high-amplitude stimulation may affect neurotransmitter re-uptake. This ultimately suggests that increasing the amplitude of ICMS device stimulation may fundamentally alter the temporal neural response, which could have implications for using amplitude to improve the ICMS effect or "offset" the effects of glial scarring.
Copyright © 2020 Elsevier Ltd. All rights reserved.

Entities:  

Keywords:  Brain stimulation; Brain-computer interface; Calcium imaging; GCaMP6; Neuromodulation; iGluSnFr

Mesh:

Substances:

Year:  2020        PMID: 31954232      PMCID: PMC7487166          DOI: 10.1016/j.biomaterials.2020.119767

Source DB:  PubMed          Journal:  Biomaterials        ISSN: 0142-9612            Impact factor:   12.479


  169 in total

1.  Over-pulsing degrades activated iridium oxide films used for intracortical neural stimulation.

Authors:  Stuart F Cogan; Andrew A Guzelian; William F Agnew; Ted G H Yuen; Douglas B McCreery
Journal:  J Neurosci Methods       Date:  2004-08-30       Impact factor: 2.390

Review 2.  Electrical stimulation of excitable tissue: design of efficacious and safe protocols.

Authors:  Daniel R Merrill; Marom Bikson; John G R Jefferys
Journal:  J Neurosci Methods       Date:  2005-02-15       Impact factor: 2.390

3.  The effect of resveratrol on neurodegeneration and blood brain barrier stability surrounding intracortical microelectrodes.

Authors:  Kelsey A Potter; Amy C Buck; Wade K Self; Megan E Callanan; Smrithi Sunil; Jeffrey R Capadona
Journal:  Biomaterials       Date:  2013-06-21       Impact factor: 12.479

4.  Electrochemically controlled release of dexamethasone from conducting polymer polypyrrole coated electrode.

Authors:  Reecha Wadhwa; Carl F Lagenaur; Xinyan Tracy Cui
Journal:  J Control Release       Date:  2005-12-19       Impact factor: 9.776

5.  Elastomeric and soft conducting microwires for implantable neural interfaces.

Authors:  Christi L Kolarcik; Silvia D Luebben; Shawn A Sapp; Jenna Hanner; Noah Snyder; Takashi D Y Kozai; Emily Chang; James A Nabity; Shawn T Nabity; Carl F Lagenaur; X Tracy Cui
Journal:  Soft Matter       Date:  2015-05-20       Impact factor: 3.679

6.  Chronic in vivo stability assessment of carbon fiber microelectrode arrays.

Authors:  Paras R Patel; Huanan Zhang; Matthew T Robbins; Justin B Nofar; Shaun P Marshall; Michael J Kobylarek; Takashi D Y Kozai; Nicholas A Kotov; Cynthia A Chestek
Journal:  J Neural Eng       Date:  2016-10-05       Impact factor: 5.379

7.  Insertion shuttle with carboxyl terminated self-assembled monolayer coatings for implanting flexible polymer neural probes in the brain.

Authors:  Takashi D Yoshida Kozai; Daryl R Kipke
Journal:  J Neurosci Methods       Date:  2009-08-08       Impact factor: 2.390

8.  Electrodeposited iridium oxide for neural stimulation and recording electrodes.

Authors:  R D Meyer; S F Cogan; T H Nguyen; R D Rauh
Journal:  IEEE Trans Neural Syst Rehabil Eng       Date:  2001-03       Impact factor: 3.802

9.  Potential-biased, asymmetric waveforms for charge-injection with activated iridium oxide (AIROF) neural stimulation electrodes.

Authors:  Stuart F Cogan; Philip R Troyk; Julia Ehrlich; Timothy D Plante; David E Detlefsen
Journal:  IEEE Trans Biomed Eng       Date:  2006-02       Impact factor: 4.538

10.  Three-photon imaging of mouse brain structure and function through the intact skull.

Authors:  Tianyu Wang; Dimitre G Ouzounov; Chunyan Wu; Nicholas G Horton; Bin Zhang; Cheng-Hsun Wu; Yanping Zhang; Mark J Schnitzer; Chris Xu
Journal:  Nat Methods       Date:  2018-09-10       Impact factor: 28.547

View more
  10 in total

1.  In vivo microstimulation with cathodic and anodic asymmetric waveforms modulates spatiotemporal calcium dynamics in cortical neuropil and pyramidal neurons of male mice.

Authors:  Kevin C Stieger; James R Eles; Kip A Ludwig; Takashi D Y Kozai
Journal:  J Neurosci Res       Date:  2020-06-26       Impact factor: 4.164

2.  Imaging the stability of chronic electrical microstimulation using electrodes coated with PEDOT/CNT and iridium oxide.

Authors:  Xin Sally Zheng; Qianru Yang; Alberto Vazquez; Xinyan Tracy Cui
Journal:  iScience       Date:  2022-06-06

3.  Intracortical microstimulation pulse waveform and frequency recruits distinct spatiotemporal patterns of cortical neuron and neuropil activation.

Authors:  Kevin C Stieger; James R Eles; Kip A Ludwig; Takashi D Y Kozai
Journal:  J Neural Eng       Date:  2022-03-31       Impact factor: 5.043

4.  Cuprizone-induced oligodendrocyte loss and demyelination impairs recording performance of chronically implanted neural interfaces.

Authors:  Steven M Wellman; Kelly Guzman; Kevin C Stieger; Lauren E Brink; Sadhana Sridhar; Mitchell T Dubaniewicz; Lehong Li; Franca Cambi; Takashi D Y Kozai
Journal:  Biomaterials       Date:  2020-02-06       Impact factor: 12.479

5.  Inhibition of Na+/H+exchanger modulates microglial activation and scar formation following microelectrode implantation.

Authors:  Mitchell Dubaniewicz; James R Eles; Stephanie Lam; Shanshan Song; Franca Cambi; Dandan Sun; Steven M Wellman; Takashi D Y Kozai
Journal:  J Neural Eng       Date:  2021-03-19       Impact factor: 5.379

6.  In vivo spatiotemporal patterns of oligodendrocyte and myelin damage at the neural electrode interface.

Authors:  Keying Chen; Steven M Wellman; Yalikun Yaxiaer; James R Eles; Takashi Dy Kozai
Journal:  Biomaterials       Date:  2020-11-23       Impact factor: 12.479

Review 7.  Electrode Materials for Chronic Electrical Microstimulation.

Authors:  Xin Sally Zheng; Chao Tan; Elisa Castagnola; Xinyan Tracy Cui
Journal:  Adv Healthc Mater       Date:  2021-05-24       Impact factor: 11.092

8.  Imaging the Efficiency of Poly(3,4-ethylenedioxythiophene) Doped with Acid-Functionalized Carbon Nanotube and Iridium Oxide Electrode Coatings for Microstimulation.

Authors:  Xin S Zheng; Qianru Yang; Alberto L Vazquez; Xinyan Tracy Cui
Journal:  Adv Nanobiomed Res       Date:  2021-05-03

Review 9.  Engineering strategies towards overcoming bleeding and glial scar formation around neural probes.

Authors:  Elisabeth Otte; Andreas Vlachos; Maria Asplund
Journal:  Cell Tissue Res       Date:  2022-01-14       Impact factor: 5.249

Review 10.  Poly(3,4-ethylenedioxythiophene)-Based Neural Interfaces for Recording and Stimulation: Fundamental Aspects and In Vivo Applications.

Authors:  Michele Bianchi; Anna De Salvo; Maria Asplund; Stefano Carli; Michele Di Lauro; Andreas Schulze-Bonhage; Thomas Stieglitz; Luciano Fadiga; Fabio Biscarini
Journal:  Adv Sci (Weinh)       Date:  2022-02-21       Impact factor: 17.521

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.