Literature DB >> 15262054

Over-pulsing degrades activated iridium oxide films used for intracortical neural stimulation.

Stuart F Cogan1, Andrew A Guzelian, William F Agnew, Ted G H Yuen, Douglas B McCreery.   

Abstract

Microelectrodes using activated iridium oxide (AIROF) charge-injection coatings have been pulsed in cat cortex at levels from near-threshold for neural excitation to the reported in vitro electrochemical charge-injection limits of AIROF. The microelectrodes were subjected to continuous biphasic current pulsing, using an 0.4V (versus Ag|AgCl) anodic bias with equal cathodal and anodal pulse widths, for periods up to 7h at a frequency of either 50Hz or 100Hz. At charge densities of 3mC/cm(2), histology revealed iridium-containing deposits in tissue adjacent to the charge-injection sites and scanning electron microscopy of explanted electrodes revealed a thickened and poorly adherent AIROF coating. Microelectrodes pulsed at 2mC/cm(2) or less remained intact, with no histologic evidence of non-biologic deposits in the tissue. AIROF microelectrodes challenged in vitro under the same pulsing conditions responded similarly, with electrodes pulsed at 3mC/cm(2) showing evidence of AIROF delamination after only 100s of pulsing at 100Hz (10,000 pulses total), while electrodes pulsed at 2mC/cm(2) for 7h at 50Hz (1.3 x 10(6) pulses total) showed no evidence of damage. In vitro electrochemical potential transient measurements in buffered physiologic saline indicate that polarizing the AIROF beyond the potential window for electrolysis of water (-0.6 to 0.8V versus Ag|AgCl) results in the observed degradation.

Entities:  

Mesh:

Substances:

Year:  2004        PMID: 15262054     DOI: 10.1016/j.jneumeth.2004.02.019

Source DB:  PubMed          Journal:  J Neurosci Methods        ISSN: 0165-0270            Impact factor:   2.390


  41 in total

1.  Strength-duration relationship for extracellular neural stimulation: numerical and analytical models.

Authors:  David Boinagrov; Jim Loudin; Daniel Palanker
Journal:  J Neurophysiol       Date:  2010-08-11       Impact factor: 2.714

2.  Sputtered iridium oxide films (SIROFs) for low-impedance neural stimulation and recording electrodes.

Authors:  S F Cogan; T D Plante; J Ehrlich
Journal:  Conf Proc IEEE Eng Med Biol Soc       Date:  2004

3.  Highly stable carbon nanotube doped poly(3,4-ethylenedioxythiophene) for chronic neural stimulation.

Authors:  Xiliang Luo; Cassandra L Weaver; David D Zhou; Robert Greenberg; Xinyan T Cui
Journal:  Biomaterials       Date:  2011-05-20       Impact factor: 12.479

4.  A Materials Roadmap to Functional Neural Interface Design.

Authors:  Steven M Wellman; James R Eles; Kip A Ludwig; John P Seymour; Nicholas J Michelson; William E McFadden; Alberto L Vazquez; Takashi D Y Kozai
Journal:  Adv Funct Mater       Date:  2017-07-19       Impact factor: 18.808

5.  Attenuation of the in vitro neurotoxicity of 316L SS by graphene oxide surface coating.

Authors:  Nishat Tasnim; Alok Kumar; Binata Joddar
Journal:  Mater Sci Eng C Mater Biol Appl       Date:  2017-01-07       Impact factor: 7.328

6.  Electron transfer processes occurring on platinum neural stimulating electrodes: calculated charge-storage capacities are inaccessible during applied stimulation.

Authors:  Eric M Hudak; Doe W Kumsa; Heidi B Martin; J Thomas Mortimer
Journal:  J Neural Eng       Date:  2017-08       Impact factor: 5.379

7.  Multimodal, longitudinal assessment of intracortical microstimulation.

Authors:  Andrew Koivuniemi; Seth J Wilks; Andrew J Woolley; Kevin J Otto
Journal:  Prog Brain Res       Date:  2011       Impact factor: 2.453

8.  Asymmetric versus symmetric pulses for cortical microstimulation.

Authors:  Andrew S Koivuniemi; Kevin J Otto
Journal:  IEEE Trans Neural Syst Rehabil Eng       Date:  2011-10-03       Impact factor: 3.802

9.  Excimer laser deinsulation of Parylene-C on iridium for use in an activated iridium oxide film-coated Utah electrode array.

Authors:  Je-Min Yoo; Sandeep Negi; Prashant Tathireddy; Florian Solzbacher; Jong-In Song; Loren W Rieth
Journal:  J Neurosci Methods       Date:  2013-02-28       Impact factor: 2.390

10.  Poly(3,4-ethylenedioxythiophene) as a Micro-Neural Interface Material for Electrostimulation.

Authors:  Seth J Wilks; Sarah M Richardson-Burns; Jeffrey L Hendricks; David C Martin; Kevin J Otto
Journal:  Front Neuroeng       Date:  2009-06-09
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.