Literature DB >> 31940527

Evaluation of Structural Anisotropy in a Porous Titanium Medium Mimicking Trabecular Bone Structure Using Mode-Converted Ultrasonic Scattering.

Hualong Du, Omid Yousefian, Timothy Horn, Marie Muller.   

Abstract

The mode-converted (longitudinal to transverse, L-T) ultrasonic scattering method was utilized to characterize the structural anisotropy of a phantom mimicking the structural properties of trabecular bone. The sample was fabricated using metal additive manufacturing from high-resolution computed tomography (CT) images of a sample of trabecular horse bone with strong anisotropy. Two focused transducers were used to perform the L-T ultrasonic measurements. A normal incidence transducer was used to transmit longitudinal ultrasonic waves into the sample, while the scattered transverse signals were received by an oblique incidence transducer. At multiple locations on the sample, four L-T measurements were performed by collecting ultrasonic scattering from four directions. The amplitude of the root mean square (rms) of the collected ultrasonic scattering signals was calculated for each L-T measurement. The ratios of rms amplitudes for L-T measurements in different directions were calculated to characterize the anisotropy of sample. The results show that the amplitude of L-T converted scattering is highly dependent on the direction of microstructural anisotropy. A strong anisotropy of the microstructure was observed, which coincides with simulation results previously published on the same structure as well as with the anisotropy estimated from the CT images. These results suggest the potential of mode-converted ultrasonic scattering methods to assess the anisotropy of materials with porous, complex structures, including trabecular bone.

Entities:  

Mesh:

Substances:

Year:  2020        PMID: 31940527      PMCID: PMC7301879          DOI: 10.1109/TUFFC.2019.2963162

Source DB:  PubMed          Journal:  IEEE Trans Ultrason Ferroelectr Freq Control        ISSN: 0885-3010            Impact factor:   2.725


  41 in total

1.  Low-megahertz ultrasonic properties of bovine cancellous bone.

Authors:  B K Hoffmeister; S A Whitten; J Y Rho
Journal:  Bone       Date:  2000-06       Impact factor: 4.398

2.  Trabecular bone pattern factor--a new parameter for simple quantification of bone microarchitecture.

Authors:  M Hahn; M Vogel; M Pompesius-Kempa; G Delling
Journal:  Bone       Date:  1992       Impact factor: 4.398

Review 3.  Looking beyond bone mineral density : Imaging assessment of bone quality.

Authors:  James F Griffith; Klaus Engelke; Harry K Genant
Journal:  Ann N Y Acad Sci       Date:  2010-03       Impact factor: 5.691

4.  Fast wave ultrasonic propagation in trabecular bone: numerical study of the influence of porosity and structural anisotropy.

Authors:  G Haïat; F Padilla; F Peyrin; P Laugier
Journal:  J Acoust Soc Am       Date:  2008-03       Impact factor: 1.840

Review 5.  Three rules for bone adaptation to mechanical stimuli.

Authors:  C H Turner
Journal:  Bone       Date:  1998-11       Impact factor: 4.398

6.  Ultrasound velocity of trabecular cubes reflects mainly bone density and elasticity.

Authors:  D Hans; C Wu; C F Njeh; S Zhao; P Augat; D Newitt; T Link; Y Lu; S Majumdar; H K Genant
Journal:  Calcif Tissue Int       Date:  1999-01       Impact factor: 4.333

7.  A backscatter difference technique for ultrasonic bone assessment.

Authors:  Brent K Hoffmeister; Anne R Wilson; Matthew J Gilbert; Mark E Sellers
Journal:  J Acoust Soc Am       Date:  2012-12       Impact factor: 1.840

Review 8.  Overview of current additive manufacturing technologies and selected applications.

Authors:  Timothy J Horn; Ola L A Harrysson
Journal:  Sci Prog       Date:  2012       Impact factor: 2.774

9.  Development of a cancellous bone structural model by stereolithography for ultrasound characterisation of the calcaneus.

Authors:  C M Langton; M A Whitehead; D K Langton; G Langley
Journal:  Med Eng Phys       Date:  1997-10       Impact factor: 2.242

Review 10.  Microarchitecture, the key to bone quality.

Authors:  Maria Luisa Brandi
Journal:  Rheumatology (Oxford)       Date:  2009-10       Impact factor: 7.580

View more
  1 in total

1.  Scattering in Cancellous Bone.

Authors:  Keith Wear
Journal:  Adv Exp Med Biol       Date:  2022       Impact factor: 3.650

  1 in total