Literature DB >> 9457693

Development of a cancellous bone structural model by stereolithography for ultrasound characterisation of the calcaneus.

C M Langton1, M A Whitehead, D K Langton, G Langley.   

Abstract

A novel method for the development of a user-defined structural model simulating cancellous bone of the human calcaneus is described using stereolithography (SL). The digital image of a cancellous bone section was modified by skeletonisation and dilation to produce a structural model of uniform wall thickness, determined by the resolution of the stereolithography system. Six SL models were produced using the same data file. The SL models were assessed using the McCue CUBAclinical ultrasound bone densitometer. The broadband ultrasound attenuation (BUA) and velocity (VOS) values obtained were commensurate with the commercial phantom provided with the CUBAclinical system. The intra- and inter-sample variability for the six SL models were similar at 5% for BUA and 2.5% for VOS. Stereolithography offers the potential to firstly, simulate perforation and thinning of cancellous bone associated with osteoporosis, and secondly, to evaluate the dependence of ultrasonic and mechanical parameters upon cancellous bone structure.

Entities:  

Mesh:

Year:  1997        PMID: 9457693     DOI: 10.1016/s1350-4533(97)00027-1

Source DB:  PubMed          Journal:  Med Eng Phys        ISSN: 1350-4533            Impact factor:   2.242


  8 in total

1.  Use of multiple acoustic wave modes for assessment of long bones: model study.

Authors:  Alexey Tatarinov; Noune Sarvazyan; Armen Sarvazyan
Journal:  Ultrasonics       Date:  2005-03-31       Impact factor: 2.890

2.  Are we crying Wolff? 3D printed replicas of trabecular bone structure demonstrate higher stiffness and strength during off-axis loading.

Authors:  Zach Wood; Lisa Lynn; Jack T Nguyen; Margaret A Black; Meha Patel; Meir M Barak
Journal:  Bone       Date:  2019-08-04       Impact factor: 4.398

3.  Characterization of a polymer, open-cell rigid foam that simulates the ultrasonic properties of cancellous bone.

Authors:  Brent K Hoffmeister; Matthew T Huber; Ann M Viano; Jinsong Huang
Journal:  J Acoust Soc Am       Date:  2018-02       Impact factor: 1.840

Review 4.  Mechanisms of Interaction of Ultrasound With Cancellous Bone: A Review.

Authors:  Keith A Wear
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2019-10-16       Impact factor: 2.725

5.  Laser stereolithography and supercritical fluid processing for custom-designed implant fabrication.

Authors:  V K Popov; A V Evseev; A L Ivanov; V V Roginski; A I Volozhin; S M Howdle
Journal:  J Mater Sci Mater Med       Date:  2004-02       Impact factor: 3.896

6.  A novel use of 3D printing model demonstrates the effects of deteriorated trabecular bone structure on bone stiffness and strength.

Authors:  Meir Max Barak; Margaret Arielle Black
Journal:  J Mech Behav Biomed Mater       Date:  2017-12-07

7.  Evaluation of Structural Anisotropy in a Porous Titanium Medium Mimicking Trabecular Bone Structure Using Mode-Converted Ultrasonic Scattering.

Authors:  Hualong Du; Omid Yousefian; Timothy Horn; Marie Muller
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2020-01-10       Impact factor: 2.725

Review 8.  3D Bioprinting Technologies for Hard Tissue and Organ Engineering.

Authors:  Xiaohong Wang; Qiang Ao; Xiaohong Tian; Jun Fan; Yujun Wei; Weijian Hou; Hao Tong; Shuling Bai
Journal:  Materials (Basel)       Date:  2016-09-27       Impact factor: 3.623

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.