Literature DB >> 3193146

Comparison of three oxygen monitors in detecting endobronchial intubation.

S J Barker1, K K Tremper, J Hyatt, H Heitzmann.   

Abstract

Rapid and reliable detection of inadvertent endobronchial intubation is an essential function of oxygen monitoring. We have studied the detection of this event by using three oxygen monitoring techniques: pulse oximetry, transcutaneous measurement of oxygen tension, and intraarterial fiberoptic measurement of oxygen tension. Four dogs were anesthetized, intubated, and monitored with these three techniques and with arterial and central venous cannulas. Endotracheal tubes were moved from the trachea into the right mainstem bronchi at several inspired oxygen fraction (FIO2) values for each dog, and the responses of the oxygen monitors were recorded for 20 minutes thereafter. The pulse oximeter showed little change in oxygen saturation (SpO2) during endobronchial intubation at FIO2 values above 0.3. SpO2 decreased by an average of 1.3 +/- 2.1% at an FIO2 of 1.0 and by 4.0 +/- 4.1% at an FIO2 of 0.5. Simultaneously measured transcutaneous oxygen tensions decreased by 42 to 64% and the optode reading decreased by 64 to 79%. At lower FIO2 values, the changes in SpO2 were more significant: a decrease of 6.0 +/- 6.3% at an FIO2 of 0.3 and of 9.8 +/- 6.1% at an FIO2 of 0.2. The transcutaneous oxygen and optode readings decreased by 31 to 45% under these conditions. Endobronchial intubations at FIO2 values greater than 0.3 may not yield immediate decreases in arterial saturation and hence may go undetected by pulse oximetry. Transcutaneous oxygen tension decreases significantly with endobronchial intubation at any FIO2. The experimental, intraarterial optode consistently yielded the greatest changes with the fastest time response.

Entities:  

Mesh:

Substances:

Year:  1988        PMID: 3193146     DOI: 10.1007/bf01617319

Source DB:  PubMed          Journal:  J Clin Monit        ISSN: 0748-1977


  11 in total

1.  Endobronchial intubation: a preventable complication.

Authors:  R L Owen; F W Cheney
Journal:  Anesthesiology       Date:  1987-08       Impact factor: 7.892

2.  Optical fluorescence and its application to an intravascular blood gas monitoring system.

Authors:  J L Gehrich; D W Lübbers; N Opitz; D R Hansmann; W W Miller; J K Tusa; M Yafuso
Journal:  IEEE Trans Biomed Eng       Date:  1986-02       Impact factor: 4.538

3.  Fiber-optic probe for in vivo measurement of oxygen partial pressure.

Authors:  J I Peterson; R V Fitzgerald; D K Buckhold
Journal:  Anal Chem       Date:  1984-01       Impact factor: 6.986

4.  Pulse oximetry during one-lung ventilation.

Authors:  J B Brodsky; M S Shulman; M Swan; J B Mark
Journal:  Anesthesiology       Date:  1985-08       Impact factor: 7.892

Review 5.  Rupture of the tracheobronchial tree.

Authors:  J C Roxburgh
Journal:  Thorax       Date:  1987-09       Impact factor: 9.139

6.  Transcutaneous oxygen measurement during one-lung anaesthesia.

Authors:  M Salmenperä; J Heinonen
Journal:  Acta Anaesthesiol Scand       Date:  1984-06       Impact factor: 2.105

7.  Continuous fiberoptic arterial oxygen tension measurements in dogs.

Authors:  S J Barker; K K Tremper; J Hyatt; J Zaccari; H A Heitzmann; B M Holman; K Pike; L S Ring; M Teope; T B Thaure
Journal:  J Clin Monit       Date:  1987-01

8.  Transcutaneous monitoring of oxygen tension during one-lung anesthesia.

Authors:  K K Tremper; H N Konchigeri; B F Cullen; P A Kapur; D Thangathurai; C Percival
Journal:  J Thorac Cardiovasc Surg       Date:  1984-07       Impact factor: 5.209

9.  Transcutaneous oxygen monitoring of critically ill adults, with and without low flow shock.

Authors:  K K Tremper; W C Shoemaker
Journal:  Crit Care Med       Date:  1981-10       Impact factor: 7.598

10.  Selective bronchial intubation in infants with lobar emphysema: indications, complications, and long-term outcome.

Authors:  J A Glenski; D W Thibeault; F K Hall; R T Hall; D R Germann
Journal:  Am J Perinatol       Date:  1986-07       Impact factor: 1.862

View more
  3 in total

Review 1.  Pulse oximetry.

Authors:  J F Kelleher
Journal:  J Clin Monit       Date:  1989-01

Review 2.  Interpretation of non-invasive oxygen and carbon dioxide data.

Authors:  K K Tremper
Journal:  Can J Anaesth       Date:  1990-05       Impact factor: 5.063

3.  Detection of endobronchial intubation by monitoring the CO2 level above the endotracheal cuff.

Authors:  Shai Efrati; Israel Deutsch; Nathan Weksler; Gabriel M Gurman
Journal:  J Clin Monit Comput       Date:  2014-05-29       Impact factor: 2.502

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.