Literature DB >> 24870932

Detection of endobronchial intubation by monitoring the CO2 level above the endotracheal cuff.

Shai Efrati1, Israel Deutsch, Nathan Weksler, Gabriel M Gurman.   

Abstract

Early detection of accidental endobronchial intubation (EBI) is still an unsolved problem in anesthesia and critical care daily practice. The aim of this study was to evaluate the ability of monitoring above cuff CO2 to detect EBI (the working hypothesis was that the origin of CO2 is from the unventilated, but still perfused, lung). Six goats were intubated under general anesthesia and the ETT positioning was verified by a flexible bronchoscope. The AnapnoGuard system, already successfully used to detect air leak around the ETT cuff, was used for continuous monitoring of above-the-cuff CO2 level. When the ETT distal tip was located in the trachea, with an average cuff pressure of 15 mmHg, absence of CO2 above the cuff was observed. The ETT was then deliberately advanced into one of the main bronchi under flexible bronchoscopic vision. In all six cases the immediate presence of CO2 above the cuff was identified. Further automatic inflation of the cuff, up to a level of 27 mmHg, did not affect the above-the-cuff measured CO2 level. Withdrawal of the ETT and repositioning of its distal tip in mid-trachea caused the disappearance of CO2 above the cuff in a maximum of 3 min, confirming the absence of air leak and the correct positioning of the ETT. Our results suggest that measurement of the above-the-cuff CO2 level could offer a reliable, on-line solution for early identification of accidental EBI. Further studies are planned to validate the efficacy of the method in a clinical setup.

Entities:  

Mesh:

Substances:

Year:  2014        PMID: 24870932     DOI: 10.1007/s10877-014-9583-5

Source DB:  PubMed          Journal:  J Clin Monit Comput        ISSN: 1387-1307            Impact factor:   2.502


  19 in total

1.  Reliability of auscultation in positioning of double-lumen endobronchial tubes.

Authors:  B Alliaume; J Coddens; T Deloof
Journal:  Can J Anaesth       Date:  1992-09       Impact factor: 5.063

2.  Alteration of endotracheal tube position. Flexion and extension of the neck.

Authors:  P A Conrardy; L R Goodman; F Lainge; M M Singer
Journal:  Crit Care Med       Date:  1976 Jan-Feb       Impact factor: 7.598

3.  Image-based monitoring of one-lung ventilation.

Authors:  S Jean; I Cinel; I Gratz; C Tay; V Lotano; E Deal; J E Parrillo; R P Dellinger
Journal:  Eur J Anaesthesiol       Date:  2008-05-20       Impact factor: 4.330

4.  Assessment of routine chest roentgenograms and the physical examination to confirm endotracheal tube position.

Authors:  W Brunel; D L Coleman; D E Schwartz; E Peper; N H Cohen
Journal:  Chest       Date:  1989-11       Impact factor: 9.410

5.  Endobronchial intubation: a preventable complication.

Authors:  R L Owen; F W Cheney
Journal:  Anesthesiology       Date:  1987-08       Impact factor: 7.892

6.  The Australian Incident Monitoring Study. Problems related to the endotracheal tube: an analysis of 2000 incident reports.

Authors:  S M Szekely; R K Webb; J A Williamson; W J Russell
Journal:  Anaesth Intensive Care       Date:  1993-10       Impact factor: 1.669

7.  Changes in PETCO2 and pulmonary blood flow after bronchial occlusion in dogs.

Authors:  D H Johnson; P C Chang; T S Hurst; F B Reynolds; S A Lang; I Mayers
Journal:  Can J Anaesth       Date:  1992-02       Impact factor: 5.063

8.  End-tidal carbon dioxide during thoracotomy. Its relation to blood level in adults and children.

Authors:  C P Heneghan; M J Scallan; M A Branthwaite
Journal:  Anaesthesia       Date:  1981-11       Impact factor: 6.955

9.  The effects of localized hypoventilation on ventilation/perfusion (V/Q) ratios and gas exchange in the dog lung.

Authors:  A J Suggett; G R Barer; F H Mohammed; G W Gill
Journal:  Clin Sci (Lond)       Date:  1982-12       Impact factor: 6.124

10.  Endobronchial intubation detected by insertion depth of endotracheal tube, bilateral auscultation, or observation of chest movements: randomised trial.

Authors:  Christian Sitzwohl; Angelika Langheinrich; Andreas Schober; Peter Krafft; Daniel I Sessler; Harald Herkner; Christopher Gonano; Christian Weinstabl; Stephan C Kettner
Journal:  BMJ       Date:  2010-11-09
View more
  5 in total

Review 1.  Journal of Clinical Monitoring and Computing 2015 end of year summary: respiration.

Authors:  D S Karbing; S E Rees; M B Jaffe
Journal:  J Clin Monit Comput       Date:  2015-12-30       Impact factor: 2.502

Review 2.  Journal of Clinical Monitoring and Computing 2015 end of year summary: anesthesia.

Authors:  Jan F A Hendrickx; Andre De Wolf; Stanley Skinner
Journal:  J Clin Monit Comput       Date:  2015-12-26       Impact factor: 2.502

3.  Continuous monitoring of endotracheal tube positioning: closer to the sangreal?

Authors:  Ahmed El Kalioubie; Saad Nseir
Journal:  J Clin Monit Comput       Date:  2015-02       Impact factor: 2.502

4.  CO2 driven endotracheal tube cuff control in critically ill patients: A randomized controlled study.

Authors:  Gennaro De Pascale; Mariano Alberto Pennisi; Maria Sole Vallecoccia; Giuseppe Bello; Riccardo Maviglia; Luca Montini; Valentina Di Gravio; Salvatore Lucio Cutuli; Giorgio Conti; Massimo Antonelli
Journal:  PLoS One       Date:  2017-05-11       Impact factor: 3.240

5.  Endotracheal Tube Migration in Steep Trendelenburg Position With the Estape TrenMAX Positioning System.

Authors:  Marisol Alvarez; Sheila Llanes Rico; Jeffrey Tsai; Robin M Schaffer; Mohammed Masri; John Sciarra; Andrzej Kuchciak
Journal:  Cureus       Date:  2021-12-24