Continuous fiberoptic arterial oxygen tension measurements in dogs.

S J Barker, K K Tremper, J Hyatt, J Zaccari, H A Heitzmann, B M Holman, K Pike, L S Ring, M Teope, T B Thaure.   

Abstract

An experimental study using a new fiberoptic sensor for the continuous intraarterial measurement of oxygen tension is described. This "optode" sensor uses the phenomenon of fluorescence quenching to determine the oxygen tension of the surrounding medium. To assess the accuracy of this device, we anesthetized 4 dogs and monitored them continuously with arterial catheters and an intraarterial optode probe, and intermittently with arterial blood gas analysis. The inspired oxygen fraction was varied from 1.0 to 0.1, and arterial blood gases were measured for comparison with the optode reading. Two hundred ninety data sets yielded a correlation coefficient of 0.96, with a linear regression slope of 0.98 and intercept of 5.1 mm Hg. In the 72 data sets from the last dog, the bias and precision of the optode arterial oxygen tension values were -10.3 mm Hg and 20.0 mm Hg, respectively. The optode probe was easily inserted through a 20-gauge catheter and did not interfere with continuous arterial pressure measurement or blood sampling. This study suggests that the optode has great potential as a continuous, real-time monitor of arterial oxygen tension.

Entities:  

Mesh:

Substances:

Year:  1987        PMID: 3819796     DOI: 10.1007/bf00770884

Source DB:  PubMed          Journal:  J Clin Monit        ISSN: 0748-1977


  7 in total

1.  Intracellular measurement of oxygen by quenching of fluorescence of pyrenebutyric acid.

Authors:  J A Knopp; I S Longmuir
Journal:  Biochim Biophys Acta       Date:  1972-09-15

2.  A simple non-thrombogenic coating.

Authors:  K Amplatz
Journal:  Invest Radiol       Date:  1971 Jul-Aug       Impact factor: 6.016

3.  Fiber-optic probe for in vivo measurement of oxygen partial pressure.

Authors:  J I Peterson; R V Fitzgerald; D K Buckhold
Journal:  Anal Chem       Date:  1984-01       Impact factor: 6.986

4.  The performance characteristics of an intra-arterial oxygen electrode.

Authors:  S V Rithalia; P J Bennett; J Tinker
Journal:  Intensive Care Med       Date:  1981       Impact factor: 17.440

5.  Statistics and ethics in medical research: V--Analysing data.

Authors:  D G Altman
Journal:  Br Med J       Date:  1980-11-29

6.  [The pCO2-/pO2-optode: a new probe for measurement of pCO2 or pO in fluids and gases (authors transl)].

Authors:  D W Lübbers; N Opitz
Journal:  Z Naturforsch C Biosci       Date:  1975 Jul-Aug

7.  Continuous polarographic monitoring of intra-arterial oxygen in the perioperative period.

Authors:  N Bratanow; K Polk; R Bland; H B Kram; T S Lee; W C Shoemaker
Journal:  Crit Care Med       Date:  1985-10       Impact factor: 7.598

  7 in total
  8 in total

Review 1.  Continuous intra-arterial blood gas monitoring.

Authors:  B Venkatesh; S P Hendry
Journal:  Intensive Care Med       Date:  1996-08       Impact factor: 17.440

2.  Blood gas optodes are accurate but fragile.

Authors:  Y Kasuya; T Nakahashi; M Takenaka; T Sakamoto; T Kato; K Suwa
Journal:  J Anesth       Date:  1994-09       Impact factor: 2.078

3.  Clinical assessment of a flow-through fluorometric blood gas monitor.

Authors:  G Bashein; J A Pino; M L Nessly; M A Kenny; K B Davis; T F Hornbein; T D Ivey
Journal:  J Clin Monit       Date:  1988-07

4.  In vitro assessment of a flow-through fluorometric blood gas monitor.

Authors:  J A Pino; G Bashein; M A Kenny
Journal:  J Clin Monit       Date:  1988-07

5.  Comparison of three oxygen monitors in detecting endobronchial intubation.

Authors:  S J Barker; K K Tremper; J Hyatt; H Heitzmann
Journal:  J Clin Monit       Date:  1988-10

6.  Progress in the development of a fluorescent intravascular blood gas system in man.

Authors:  C K Mahutte; C S Sassoon; J R Muro; D R Hansmann; T P Maxwell; W W Miller; M Yafuso
Journal:  J Clin Monit       Date:  1990-04

7.  Detection of venous air embolism by continuous intraarterial oxygen monitoring.

Authors:  G Greenblott; S J Barker; K K Tremper; S Gerschultz; J L Gehrich
Journal:  J Clin Monit       Date:  1990-01

8.  Continuous assessment of arterial blood gases.

Authors: 
Journal:  Crit Care       Date:  1997       Impact factor: 9.097

  8 in total