Literature DB >> 7285607

Transcutaneous oxygen monitoring of critically ill adults, with and without low flow shock.

K K Tremper, W C Shoemaker.   

Abstract

One hundred and six critically ill adult patients were monitored continuously with a transcutaneous oxygen sensor (PtcO2); they also were intermittently monitored with conventional invasive hemodynamic and oxygen transport variables. A total of 1073 data sets were taken on 41 patients in the ICU and 65 patients in the operating room. The patients were divided into three groups by cardiac index (CI): relatively normal flow, CI greater than 2.2 L/min x M2; moderate low flow shock, 2.2 greater than CI greater than 1.5 L/min x M2; and severe low flow shock, CI less than 1.5 L/min x M2 x PtcO2 and arterial oxygen tension (PaO2) were compared in two ways: first by linear regression and second by a more simple clinical guide by indexing each transcutaneous value by its respective arterial value (PtcO2 index = PtcO2/PaO2). For 934 data sets taken on 92 patients not in shock, there was a correlation coefficient (r) of 0.89 and a PtcO2 index 0.79 +/- 0.12 (SD). In 5 patients with moderate shock, the r was 0.78 and the PtcO2 index was 0.48 +/- 0.07. In 9 patients with severe shock, there was no correlation between PtcO2 and PaO2 and the PtcO2 index was 0.12 +/- 0.12. In all cases of severe shock, the PtcO2 value responded quickly to changes in blood flow with an approximate 1 min response time (95%). The patients not in shock responded to changes in inspired oxygen concentration (FIO2) with changes in PaO2 and PtcO2 values; the 95% response time was approximately 2 min. The authors conclude that the normal value for PtcO2 for adult surgical patients who are hemodynamically stable is 79 +/- 12% of the PaO2 and that PtcO2 values were reliable, continuous, noninvasive trend monitors of PaO2 in these patients. During circulatory problems when PtcO2 values were compared to PaO2 values (PtcO2 index), the changes reflected trends in the severity of low flow shock.

Entities:  

Mesh:

Substances:

Year:  1981        PMID: 7285607     DOI: 10.1097/00003246-198110000-00007

Source DB:  PubMed          Journal:  Crit Care Med        ISSN: 0090-3493            Impact factor:   7.598


  34 in total

Review 1.  Accident and emergency medicine--II.

Authors:  R C Evans; R J Evans
Journal:  Postgrad Med J       Date:  1992-10       Impact factor: 2.401

2.  Respiratory monitoring of carbon dioxide and oxygen: a ten-year perspective.

Authors:  M Weingarten
Journal:  J Clin Monit       Date:  1990-07

Review 3.  Noninvasive monitoring of peripheral perfusion.

Authors:  Alexandre Lima; Jan Bakker
Journal:  Intensive Care Med       Date:  2005-09-17       Impact factor: 17.440

Review 4.  Non-pharmacologic prevention of surgical wound infection.

Authors:  Daniel I Sessler
Journal:  Anesthesiol Clin       Date:  2006-06

5.  Continuous monitoring of interstitial tissue oxygen using subcutaneous oxygen microsensors: In vivo characterization in healthy volunteers.

Authors:  Stephen C Kanick; Peter A Schneider; Bruce Klitzman; Natalie A Wisniewski; Kerstin Rebrin
Journal:  Microvasc Res       Date:  2019-02-08       Impact factor: 3.514

6.  The role of pulse oximetry in the accident and emergency department.

Authors:  M A Lambert; J Crinnion
Journal:  Arch Emerg Med       Date:  1989-09

7.  Non-invasive tools for guiding hemodynamic resuscitation in septic shock: the perfusion vs metabolic issue.

Authors:  Jaume Mesquida
Journal:  J Clin Monit Comput       Date:  2020-11-30       Impact factor: 2.502

Review 8.  Transcutaneous PO2 measurement.

Authors:  K K Tremper
Journal:  Can Anaesth Soc J       Date:  1984-11

9.  Effects of the electrode temperature of a new monitor, TCM4, on the measurement of transcutaneous oxygen and carbon dioxide tension.

Authors:  Tomoki Nishiyama; Shinji Nakamura; Koichi Yamashita
Journal:  J Anesth       Date:  2006       Impact factor: 2.078

10.  Transorally obtained oxygen tension as an indicator of arterial oxygen tension.

Authors:  S E Opper; E E Fibuch; G F Tuohy
Journal:  J Clin Monit       Date:  1988-04
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.