Literature DB >> 3177025

First Hungarian neurosurgical experiences with "Fixateur Interne" in the treatment of thoraco-lumbar spine injuries. Technical note.

T Pentelényi1, S Zsolczai.   

Abstract

The Fixateur Interne (F.I.) is a new device for internal fixation of the thoraco-lumbar spine developed by Dick and Magerl. It is based on a new principle since it does not act as a four-point bending system like long rod instrumentations but it is a two-point fixation system and it is stable in flection by itself. Because the system seems not well known among neurosurgeons, its use and advantages are described and two cases reported.

Mesh:

Year:  1988        PMID: 3177025     DOI: 10.1007/bf01402890

Source DB:  PubMed          Journal:  Acta Neurochir (Wien)        ISSN: 0001-6268            Impact factor:   2.216


  23 in total

1.  Specific selection of osteosynthetic material in the treatment of thoracic or lumbar spinal injuries by the posterior approach. A review of 165 cases.

Authors:  F Lesoin; M Rousseaux; N Bouasakao; L Villette; C E Thomas; A Cama; M Jomin
Journal:  Acta Neurochir (Wien)       Date:  1986       Impact factor: 2.216

2.  The development and further prospects of internal fixation of the spine.

Authors:  P R Harrington; J H Dickson
Journal:  Isr J Med Sci       Date:  1973-06

3.  Segmental spinal instrumentation in the treatment of fractures of the thoracolumbar spine.

Authors:  E R Luque; N Cassis; G Ramírez-Wiella
Journal:  Spine (Phila Pa 1976)       Date:  1982 May-Jun       Impact factor: 3.468

4.  Stabilization of the lower thoracic and lumbar spine with external skeletal fixation.

Authors:  F P Magerl
Journal:  Clin Orthop Relat Res       Date:  1984-10       Impact factor: 4.176

5.  The role of the anterior longitudinal ligament in Harrington rod fixation of unstable thoracolumbar spinal fractures.

Authors:  U Andén; A Lake; A Nordwall
Journal:  Spine (Phila Pa 1976)       Date:  1980 Jan-Feb       Impact factor: 3.468

6.  [Treatment of vertebral fractures and dislocations of the thoraco-lumbar area (author's transl)].

Authors:  R Roy-Camille; G Saillant; S Marie-Anne; P Mamoudy
Journal:  Orthopade       Date:  1980-01       Impact factor: 1.087

7.  Twelfth thoracic-first lumbar vertebral mechanical stability of fractures after Harrington-rod instrumentation.

Authors:  G A Purcell; K L Markolf; E G Dawson
Journal:  J Bone Joint Surg Am       Date:  1981-01       Impact factor: 5.284

8.  Gait abnormalities arising from latrogenic loss of lumbar lordosis secondary to Harrington instrumentation in lumbar fractures.

Authors:  C A Hasday; T L Passoff; J Perry
Journal:  Spine (Phila Pa 1976)       Date:  1983 Jul-Aug       Impact factor: 3.468

9.  A new device for internal fixation of thoracolumbar and lumbar spine fractures: the 'fixateur interne'.

Authors:  W Dick; P Kluger; F Magerl; O Woersdörfer; G Zäch
Journal:  Paraplegia       Date:  1985-08

10.  Fracture-dislocation of the dorsal-lumbar spine. Acute operative stabilization by Harrington instrumentation.

Authors:  F R Convery; M A Minteer; R W Smith; S M Emerson
Journal:  Spine (Phila Pa 1976)       Date:  1978-06       Impact factor: 3.468

View more
  4 in total

1.  Near-anatomical reduction and stabilization of burst fractures of the lower thoracic or lumbar spine.

Authors:  C Silvestro; N Francaviglia; R Bragazzi; G L Viale
Journal:  Acta Neurochir (Wien)       Date:  1992       Impact factor: 2.216

2.  Management of thoraco-lumbar fractures.

Authors:  M L Babu; M A Wani
Journal:  Acta Neurochir (Wien)       Date:  1990       Impact factor: 2.216

Review 3.  Percutaneous interbody osteosynthesis in the treatment of thoracolumbar traumatic or tumoural lesions. A review of 51 cases.

Authors:  G Lozes; A Fawaz; P Mescola; T Marnay; M Herlant; P Devos; A Cama; G O Sertl; M Brambillas Bas; X Leclercq
Journal:  Acta Neurochir (Wien)       Date:  1990       Impact factor: 2.216

4.  Results of the AO spinal internal fixator in the surgical treatment of thoracolumbar burst fractures.

Authors:  S Akalm; M Kiş; I T Benli; M Citak; E F Mumcu; M Tüzüner
Journal:  Eur Spine J       Date:  1994       Impact factor: 3.134

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.