Literature DB >> 3900882

A new device for internal fixation of thoracolumbar and lumbar spine fractures: the 'fixateur interne'.

W Dick, P Kluger, F Magerl, O Woersdörfer, G Zäch.   

Abstract

A new system of operative fixation of thoracolumbar and lumbar spine fractures is presented: the 'fixateur interne' (F.I.). From a posterior approach long Schanz screws are inserted through the pedicles into the body of the two vertebrae just adjacent to the lesion and connected by th threaded F.I. rods. By tightening the nuts the Schanz screws are fixed in all directions. The advantages of the F.I. system are: excellent reposition by the long lever-arm of the Schanz screws, immobilization of only two segments and therefore good mobility of the residual spine, stability against flexion forces better than is obtained with Harrington distraction rods, additional rotational stability, and fixation in lordosis or kyphosis as is desired. The F.I. does not act as a four point bending system like all other dorsal spine instrumentation systems, but provides stability in flexion by itself. Therefore it can be Used independently of the condition of all ligaments (including the anterior longitudinal ligament) and of the posterior wall of the fractured vertebrae, and there is no need to fix more than the two immediately adjacent vertebrae, thus avoiding the often painful and cumbersome iatrogenic loss of lumbar lordosis and of mobility and permitting early mobilization of the patient. Experience with the first 45 patients is very promising.

Entities:  

Mesh:

Year:  1985        PMID: 3900882     DOI: 10.1038/sc.1985.38

Source DB:  PubMed          Journal:  Paraplegia        ISSN: 0031-1758


  52 in total

1.  Operative treatment of unstable thoracolumbar fractures by the posterior approach with the use of Williams plates or Harrington rods.

Authors:  M Karjalainen; A J Aho; K Katevuo
Journal:  Int Orthop       Date:  1992       Impact factor: 3.075

2.  Kluger's "fixateur interne" for spinal instability.

Authors:  G Sandvoss; H Feldmann
Journal:  Neurosurg Rev       Date:  1991       Impact factor: 3.042

3.  Management of thoraco-lumbar fractures.

Authors:  M L Babu; M A Wani
Journal:  Acta Neurochir (Wien)       Date:  1990       Impact factor: 2.216

4.  Comparison of open versus percutaneous pedicle screw insertion in a sheep model.

Authors:  W Lehmann; A Ushmaev; A Ruecker; J Nuechtern; L Grossterlinden; P G Begemann; T Baeumer; J M Rueger; D Briem
Journal:  Eur Spine J       Date:  2008-04-04       Impact factor: 3.134

5.  Sagittal range of motion after a spinal fracture: does ROM correlate with functional outcome?

Authors:  R B Post; V J M Leferink
Journal:  Eur Spine J       Date:  2004-04-09       Impact factor: 3.134

6.  Reduction and stabilization of lumbar and thoracolumbar spine fractures with Louis' plates and internal fixator: a comparative study.

Authors:  P Zangger; T Pache
Journal:  Eur Spine J       Date:  1993-10       Impact factor: 3.134

7.  Treatment of unstable thoracolumbar burst fractures by indirect reduction and posterior stabilization: short-segment versus long-segment stabilization.

Authors:  George Sapkas; Konstantinos Kateros; Stamatios A Papadakis; Emmanouel Brilakis; George Macheras; Pavlos Katonis
Journal:  Open Orthop J       Date:  2010-01-15

8.  The effect of postoperative immobilization on short-segment fixation without bone grafting for unstable fractures of thoracolumbar spine.

Authors:  Sh Lee; Ds Pandher; Ks Yoon; St Lee; Kwang Jun Oh
Journal:  Indian J Orthop       Date:  2009-04       Impact factor: 1.251

9.  Comparison of surgical outcomes in thoracolumbar fractures operated with posterior constructs having varying fixation length with selective anterior fusion.

Authors:  Hak Sun Kim; Seung Yup Lee; Ankur Nanda; Ju Young Kim; Jin Oh Park; Seong Hwan Moon; Hwan Mo Lee; Ho Joong Kim; Huan Wei; Eun Su Moon
Journal:  Yonsei Med J       Date:  2009-08-19       Impact factor: 2.759

10.  Two levels above and one level below pedicle screw fixation for the treatment of unstable thoracolumbar fracture with partial or intact neurology.

Authors:  Hitesh N Modi; Kook Jin Chung; Il Woo Seo; Hoi Soo Yoon; Ji Hyo Hwang; Hong Kyun Kim; Kyu Cheol Noh; Jung Han Yoo
Journal:  J Orthop Surg Res       Date:  2009-07-27       Impact factor: 2.359

View more